A Biomechanical Assessment of three Types of Plating Systems in a Combined Mandibular Parasymphysis and Angle Fracture - An In vitro Study.

Q2 Dentistry
Annals of Maxillofacial Surgery Pub Date : 2026-01-01 Epub Date: 2026-06-17 DOI:10.4103/ams.ams_211_25
Apoorva Basavaraj Kumbar, P Hema Mythily, Girish B Giraddi, K Sridevi
{"title":"A Biomechanical Assessment of three Types of Plating Systems in a Combined Mandibular Parasymphysis and Angle Fracture - An <i>In vitro</i> Study.","authors":"Apoorva Basavaraj Kumbar, P Hema Mythily, Girish B Giraddi, K Sridevi","doi":"10.4103/ams.ams_211_25","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Mandibular fractures are the most encountered fractures by oral and maxillofacial surgeons, and for their fixation, different systems have been studied and used in clinical practice. Miniplates in lines of osteosynthesis described by Champy have stood the challenge of time for maxillofacial fractures. Many designs have been proposed since then. Three-dimensional (3D) plates, designed to have a geometric shape, claimed to add strength and stability to fracture fragments. Locking plates were designed to have screws that lock in the plate and thus provide added stability to fixation.</p><p><strong>Materials and methods: </strong>The aim of this study was to compare the efficacy of three internal fixation systems for osteosynthesis of combined angle and parasymphysis mandibular fractures. Fifteen sheep mandibles were used. Osteotomy simulating parasymphysis and contralateral angle fracture were done and fixed with three plating systems, 5 in each group. Group A with straight non-locking miniplates, Group B with 3D miniplates and Group C with locking miniplates. Universal Testing Machine was used to apply force ranging from 0 to 900 Newton (N) on the occlusal surface. The forces which caused significant displacement between fracture segments were recorded. The <i>post hoc</i> test showed significance between forces in the groups, i.e., <i>P</i> < 0.05.</p><p><strong>Results: </strong>Plates which least resisted displacement between fractured segments were straight non-locking miniplates with a mean end-point force of 109.20N, as compared to 3D plates, 327N and locking plates, 345.2.</p><p><strong>Discussion: </strong>Biomechanically, locking miniplates are more efficient than 3D miniplates which in turn are more efficient than non-locking miniplates in an <i>in vitro</i> scenario.</p>","PeriodicalId":7972,"journal":{"name":"Annals of Maxillofacial Surgery","volume":"16 1","pages":"66-70"},"PeriodicalIF":0.0000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13456622/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Maxillofacial Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ams.ams_211_25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Mandibular fractures are the most encountered fractures by oral and maxillofacial surgeons, and for their fixation, different systems have been studied and used in clinical practice. Miniplates in lines of osteosynthesis described by Champy have stood the challenge of time for maxillofacial fractures. Many designs have been proposed since then. Three-dimensional (3D) plates, designed to have a geometric shape, claimed to add strength and stability to fracture fragments. Locking plates were designed to have screws that lock in the plate and thus provide added stability to fixation.

Materials and methods: The aim of this study was to compare the efficacy of three internal fixation systems for osteosynthesis of combined angle and parasymphysis mandibular fractures. Fifteen sheep mandibles were used. Osteotomy simulating parasymphysis and contralateral angle fracture were done and fixed with three plating systems, 5 in each group. Group A with straight non-locking miniplates, Group B with 3D miniplates and Group C with locking miniplates. Universal Testing Machine was used to apply force ranging from 0 to 900 Newton (N) on the occlusal surface. The forces which caused significant displacement between fracture segments were recorded. The post hoc test showed significance between forces in the groups, i.e., P < 0.05.

Results: Plates which least resisted displacement between fractured segments were straight non-locking miniplates with a mean end-point force of 109.20N, as compared to 3D plates, 327N and locking plates, 345.2.

Discussion: Biomechanically, locking miniplates are more efficient than 3D miniplates which in turn are more efficient than non-locking miniplates in an in vitro scenario.

三种类型的钢板系统在下颌骨副骨和角骨折联合治疗中的生物力学评价-体外研究。
下颌骨骨折是口腔颌面外科医生最常遇到的骨折,对于其固定,不同的系统已经被研究并用于临床实践。由Champy描述的骨合成线中的微型钢板经受住了时间对颌面骨折的挑战。从那时起,人们提出了许多设计方案。三维(3D)钢板被设计成几何形状,据称可以增加断裂碎片的强度和稳定性。锁定钢板被设计成有螺钉锁定钢板,从而增加固定的稳定性。材料和方法:本研究的目的是比较三种内固定系统对下颌联合角骨折和副骨骨折的植骨效果。使用了15只羊的下颌骨。模拟副椎体骨折和对侧角骨折行截骨术,每组5个钢板固定。A组为直线型无锁定微型板,B组为三维微型板,C组为锁定微型板。使用万能试验机在咬合面上施加0 - 900牛顿(N)的力。记录了造成骨折段之间显著位移的力。事后检验各组力间差异有统计学意义,P < 0.05。结果:骨折节段间抵抗位移最小的是直型非锁定微型钢板,平均端点力为109.20N,而三维钢板为327N,锁定钢板为345.2 n。讨论:从生物力学角度来看,锁定微型钢板比3D微型钢板更有效,3D微型钢板又比非锁定微型钢板更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
26
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书