Optical coherence tomography-guided decision-making for Descemet stripping automated endothelial keratoplasty in Ahmed glaucoma valve-related corneal decompensation.

Vijay Kumar Sharma, Prabhjot Singh, Gaurav Kapoor, Vikas Ambiya, Sagrika Patyal
{"title":"Optical coherence tomography-guided decision-making for Descemet stripping automated endothelial keratoplasty in Ahmed glaucoma valve-related corneal decompensation.","authors":"Vijay Kumar Sharma, Prabhjot Singh, Gaurav Kapoor, Vikas Ambiya, Sagrika Patyal","doi":"10.22336/rjo.2026.36","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Ahmed glaucoma valve (AGV) implantation can lead to corneal decompensation in a significant proportion of patients. Anterior segment optical coherence tomography (ASOCT) evaluation may serve as a crucial tool for assessing AGV retention versus explantation and for planning Descemet stripping automated endothelial keratoplasty (DSAEK) in such cases. This study aims to evaluate the utility of ASOCT in guiding management decisions for AGV-related corneal decompensation.</p><p><strong>Materials and methods: </strong>In this prospective interventional study, 11 eyes with AGV-related corneal decompensation were evaluated using anterior segment 5-line raster-mode OCT measurements. Parameters assessed included stromal scarring, corneal thickness, and tube tip to endothelium (TTE) distance. ASOCT findings guided management decisions: four patients with nonfunctional AGVs underwent staged procedures (AGV removal with augmented trabeculectomy, followed by DSAEK), while seven patients underwent DSAEK alone (six with functional AGVs with TTE distance > 150 μm; one patient with a non-functional AGV refused consent for AGV explantation).</p><p><strong>Results: </strong>All patients demonstrated significant improvement in best-corrected visual acuity with well-controlled intraocular pressure. Graft attachment was successful in all cases except one patient who experienced detachment after one month. Based on our findings, we proposed a protocol for managing AGV-related corneal decompensation.</p><p><strong>Discussion: </strong>Tube shunt implantation effectively reduces intraocular pressure in eyes with uncontrolled glaucoma but can lead to significant endothelial cell loss and corneal decompensation. In this series, two major challenges were addressed: the decision regarding AGV tube removal and its risks, and the determination of a safe tube-tip-to-endothelium (TTE) distance to prevent graft damage after DSAEK. We considered a preoperative TTE greater than 150 μm to be safe for single-stage DSAEK without AGV modification, accounting for lenticule thickness and the anticipated reduction in corneal edema. ASOCT-guided measurement of TTE distance proved invaluable for predicting complications and guiding surgical decision-making, with outcomes that support our proposed management protocol.</p><p><strong>Conclusion: </strong>While performing DSAEK in patients with AGV-related corneal decompensation presents significant challenges, ASOCT is an essential modality for guiding surgical decision-making regarding AGV explantation versus retention and subsequent DSAEK.</p>","PeriodicalId":94355,"journal":{"name":"Romanian journal of ophthalmology","volume":"70 2","pages":"272-278"},"PeriodicalIF":0.0000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13453119/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22336/rjo.2026.36","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Ahmed glaucoma valve (AGV) implantation can lead to corneal decompensation in a significant proportion of patients. Anterior segment optical coherence tomography (ASOCT) evaluation may serve as a crucial tool for assessing AGV retention versus explantation and for planning Descemet stripping automated endothelial keratoplasty (DSAEK) in such cases. This study aims to evaluate the utility of ASOCT in guiding management decisions for AGV-related corneal decompensation.

Materials and methods: In this prospective interventional study, 11 eyes with AGV-related corneal decompensation were evaluated using anterior segment 5-line raster-mode OCT measurements. Parameters assessed included stromal scarring, corneal thickness, and tube tip to endothelium (TTE) distance. ASOCT findings guided management decisions: four patients with nonfunctional AGVs underwent staged procedures (AGV removal with augmented trabeculectomy, followed by DSAEK), while seven patients underwent DSAEK alone (six with functional AGVs with TTE distance > 150 μm; one patient with a non-functional AGV refused consent for AGV explantation).

Results: All patients demonstrated significant improvement in best-corrected visual acuity with well-controlled intraocular pressure. Graft attachment was successful in all cases except one patient who experienced detachment after one month. Based on our findings, we proposed a protocol for managing AGV-related corneal decompensation.

Discussion: Tube shunt implantation effectively reduces intraocular pressure in eyes with uncontrolled glaucoma but can lead to significant endothelial cell loss and corneal decompensation. In this series, two major challenges were addressed: the decision regarding AGV tube removal and its risks, and the determination of a safe tube-tip-to-endothelium (TTE) distance to prevent graft damage after DSAEK. We considered a preoperative TTE greater than 150 μm to be safe for single-stage DSAEK without AGV modification, accounting for lenticule thickness and the anticipated reduction in corneal edema. ASOCT-guided measurement of TTE distance proved invaluable for predicting complications and guiding surgical decision-making, with outcomes that support our proposed management protocol.

Conclusion: While performing DSAEK in patients with AGV-related corneal decompensation presents significant challenges, ASOCT is an essential modality for guiding surgical decision-making regarding AGV explantation versus retention and subsequent DSAEK.

光学相干层析成像引导下艾哈迈德青光眼瓣膜相关性角膜失代偿中Descemet剥离自动内皮角膜移植术的决策。
目的:Ahmed青光眼瓣膜(AGV)植入术可导致相当比例的患者角膜失代偿。在这种情况下,前段光学相干断层扫描(ASOCT)评估可以作为评估AGV保留与外植的关键工具,并计划Descemet剥离自动内皮角膜移植术(DSAEK)。本研究旨在评估ASOCT在指导agv相关角膜失代偿管理决策中的作用。材料和方法:在这项前瞻性介入研究中,使用前段5线光栅模式OCT测量对11只患有agv相关角膜失代偿的眼睛进行评估。评估的参数包括基质瘢痕、角膜厚度和管尖到内皮(TTE)的距离。ASOCT结果指导了管理决策:4例无功能AGV患者接受了分阶段的手术(AGV切除加增强小梁切除术,然后进行DSAEK),而7例患者单独接受了DSAEK(6例功能AGV, TTE距离> 150 μm; 1例无功能AGV患者拒绝同意AGV外植)。结果:所有患者的最佳矫正视力均有明显改善,眼压控制良好。除1例患者1个月后出现脱离外,所有病例移植物附着均成功。基于我们的研究结果,我们提出了一种治疗agv相关角膜失代偿的方案。讨论:在不受控制的青光眼中,管分流植入术可有效降低眼压,但可导致明显的内皮细胞丢失和角膜失代偿。在本系列文章中,我们解决了两个主要的挑战:决定AGV管的移除及其风险,以及确定一个安全的管尖到内皮(TTE)距离以防止DSAEK后移植物损伤。考虑到晶状体厚度和预期的角膜水肿减少,我们认为术前TTE大于150 μm对单期DSAEK是安全的,无需AGV修改。asoct引导下的TTE距离测量在预测并发症和指导手术决策方面被证明是非常宝贵的,其结果支持我们提出的管理方案。结论:虽然在AGV相关性角膜失代偿患者中进行DSAEK存在重大挑战,但ASOCT是指导手术决策的重要模式,可用于AGV移植与保留以及随后的DSAEK。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书