Equivalence of linear facial measurements obtained from smartphone-based 3-dimensional facial scanners and professional extraoral scanners: A retrospective clinical study

IF 5.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Prosthetic Dentistry Pub Date : 2026-10-01 Epub Date: 2026-08-08 DOI:10.1016/j.prosdent.2026.07.015
Justine Bouscasse DDS, Virginie Chuy DDS, PhD, Louise Viel DDS, Adrien Laran DDS, Adrien Naveau DDS, PhD
{"title":"Equivalence of linear facial measurements obtained from smartphone-based 3-dimensional facial scanners and professional extraoral scanners: A retrospective clinical study","authors":"Justine Bouscasse DDS,&nbsp;Virginie Chuy DDS, PhD,&nbsp;Louise Viel DDS,&nbsp;Adrien Laran DDS,&nbsp;Adrien Naveau DDS, PhD","doi":"10.1016/j.prosdent.2026.07.015","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.</div></div><div>Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.</div><div><h3>Purpose</h3><div>The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.</div></div><div>The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.</div><div><h3>Material and methods</h3><div>Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided <em>t</em> tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.</div></div><div>Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided <em>t</em> tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.</div><div><h3>Results</h3><div>Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; <em>P</em>&lt;.001 for all comparisons).</div></div><div>Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; <em>P</em>&lt;.001 for all comparisons).</div><div><h3>Conclusions</h3><div>Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.</div></div><div>Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.</div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"136 4","pages":"Pages 1200-1206"},"PeriodicalIF":5.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391326005184","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.
Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.

Purpose

The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.
The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.

Material and methods

Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided t tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.
Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided t tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.

Results

Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; P<.001 for all comparisons).
Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; P<.001 for all comparisons).

Conclusions

Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.
Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.
基于智能手机的三维面部扫描仪和专业口外扫描仪获得的线性面部测量的等效性:一项回顾性临床研究
问题说明:三维(3D)面部扫描已经越来越多地集成到数字牙科工作流程中。基于智能手机的3D面部扫描应用程序为专业口腔外扫描仪提供了一种可访问的替代方案;然而,它们在临床相关面部测量中的有效性尚不清楚。目的:本回顾性临床研究的目的是确定基于智能手机的3D面部扫描应用程序获得的线性面部测量数据是否与专业口外面部扫描仪获得的数据在统计学上相等。材料和方法:对23名参与者的面部扫描进行回顾性分析,这些面部扫描是通过基于智能手机的扫描仪(Qlone、Magiscan、3D App Scanner、iPhone 13 Pro、Apple Inc)和专业扫描仪(Artec Spider、Artec、EinStar、Shining 3D)反复扫描获得的。在所有扫描中测量四种面部距离(前倾-鼻斜,鼻斜-鼻斜,前倾-鼻斜,右颧-左颧)。使用两个单侧t检验(TOST)程序评估基于智能手机的扫描仪和每个专业扫描仪之间这些距离的等效性,预定义等效裕度为±1 mm和bonferroni调整显著性水平。结果:在所有距离上,基于智能手机和专业扫描仪在统计上是相等的,绝对平均差值低于0.12 mm(90%置信区间:-0.03至0.26)。结论:基于智能手机的3D面部扫描应用提供的线性面部测量数据在统计上与专业口外扫描仪在选定距离上获得的数据相当。这些应用程序可以被认为是有效的牙科针对性临床应用,并作为数字工作流程中的补充工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书