Equivalence of linear facial measurements obtained from smartphone-based 3-dimensional facial scanners and professional extraoral scanners: A retrospective clinical study
Justine Bouscasse DDS, Virginie Chuy DDS, PhD, Louise Viel DDS, Adrien Laran DDS, Adrien Naveau DDS, PhD
{"title":"Equivalence of linear facial measurements obtained from smartphone-based 3-dimensional facial scanners and professional extraoral scanners: A retrospective clinical study","authors":"Justine Bouscasse DDS, Virginie Chuy DDS, PhD, Louise Viel DDS, Adrien Laran DDS, Adrien Naveau DDS, PhD","doi":"10.1016/j.prosdent.2026.07.015","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.</div></div><div>Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.</div><div><h3>Purpose</h3><div>The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.</div></div><div>The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.</div><div><h3>Material and methods</h3><div>Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided <em>t</em> tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.</div></div><div>Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided <em>t</em> tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.</div><div><h3>Results</h3><div>Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; <em>P</em><.001 for all comparisons).</div></div><div>Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; <em>P</em><.001 for all comparisons).</div><div><h3>Conclusions</h3><div>Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.</div></div><div>Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.</div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"136 4","pages":"Pages 1200-1206"},"PeriodicalIF":5.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391326005184","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Statement of problem
Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.
Three-dimensional (3D) facial scanning has been increasingly integrated into digital dental workflows. Smartphone-based 3D facial scanning applications offer an accessible alternative to professional extraoral scanners; however, their metric validity for clinically relevant facial measurements remains unclear.
Purpose
The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.
The purpose of this retrospective clinical study was to determine whether linear facial measurements obtained from smartphone-based 3D facial scanning applications were statistically equivalent to those obtained from professional extraoral facial scanners.
Material and methods
Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided t tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.
Facial scans from 23 participants, obtained via repeated scanning with smartphone-based scanners (Qlone, Magiscan, 3D App Scanner, on iPhone 13 Pro; Apple Inc) and professional scanners (Artec Spider; Artec, EinStar; Shining 3D), were retrospectively analyzed. Four facial distances (trichion–nasion, nasion–pronasion, pronasion–pogonion, and right zygomatic–left zygomatic) were measured on all scans. The equivalence of these distances between smartphone-based scanners and each professional scanner was assessed using the two 1-sided t tests (TOST) procedure with a predefined equivalence margin of ±1 mm and Bonferroni-adjusted significance levels.
Results
Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; P<.001 for all comparisons).
Across all distances, smartphone-based and professional scanners were statistically equivalent, with absolute mean differences below 0.12 mm (90% confidence interval: −0.03 to 0.26; P<.001 for all comparisons).
Conclusions
Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.
Smartphone-based 3D facial scanning applications provided linear facial measurements that were statistically equivalent to those obtained from professional extraoral scanners for selected distances. These applications may be considered valid for targeted clinical applications in dentistry and as complementary tools within digital workflows.
期刊介绍:
The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.