A lightweight passive ankle exoskeleton with dual-phase energy harvesting and stiffness adaptation.

IF 3.5 Q2 ENGINEERING, BIOMEDICAL
Wearable technologies Pub Date : 2026-08-04 eCollection Date: 2026-01-01 DOI:10.1017/wtc.2026.10046
Kaitai Li, Zhao Yang, Heyuan Wang, Xuesong Ye, Congcong Zhou
{"title":"A lightweight passive ankle exoskeleton with dual-phase energy harvesting and stiffness adaptation.","authors":"Kaitai Li, Zhao Yang, Heyuan Wang, Xuesong Ye, Congcong Zhou","doi":"10.1017/wtc.2026.10046","DOIUrl":null,"url":null,"abstract":"<p><p>Passive exoskeletons offer several advantages, including lightweight design, simple structure, and inherent energy efficiency. Most existing passive exoskeletons rely on clutch mechanisms to control spring-based energy storage and release, typically focusing only on recovering biomechanical energy during the stance phase of gait. In this study, we propose and analyze a lightweight passive ankle exoskeleton capable of harvesting and releasing energy during both the stance and swing phases of walking. The device aims to enhance gait assistance while maintaining structural simplicity and minimizing weight. By integrating the optimal stiffness ratio between the stance and swing phases, derived from musculoskeletal model simulations, with previously established optimal stance-phase stiffness parameters, we determined a suitable stiffness coefficient for the swing-phase spring. To validate the design, we conducted comparative experiments on participants walking with exoskeletons configured with different stiffness coefficients. Spatiotemporal parameters, metabolic energy cost, and muscle activation patterns were analyzed to evaluate performance. The results demonstrate that the proposed exoskeleton effectively reduces Soleus muscle activation while increasing tibialis anterior activity, leading to a 6.84% reduction in walking energy cost compared to a nonassistive condition. Furthermore, energy recovery during the swing phase alone contributes an additional 1.67% reduction in energy expenditure, improving overall walking efficiency. The proposed design also eliminates complex clutch components, significantly simplifying manufacturing and reducing costs, thereby enhancing the applicability of passive exoskeletons in daily mobility and rehabilitation scenarios.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":"7 ","pages":"e10"},"PeriodicalIF":3.5000,"publicationDate":"2026-08-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13444395/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2026.10046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Passive exoskeletons offer several advantages, including lightweight design, simple structure, and inherent energy efficiency. Most existing passive exoskeletons rely on clutch mechanisms to control spring-based energy storage and release, typically focusing only on recovering biomechanical energy during the stance phase of gait. In this study, we propose and analyze a lightweight passive ankle exoskeleton capable of harvesting and releasing energy during both the stance and swing phases of walking. The device aims to enhance gait assistance while maintaining structural simplicity and minimizing weight. By integrating the optimal stiffness ratio between the stance and swing phases, derived from musculoskeletal model simulations, with previously established optimal stance-phase stiffness parameters, we determined a suitable stiffness coefficient for the swing-phase spring. To validate the design, we conducted comparative experiments on participants walking with exoskeletons configured with different stiffness coefficients. Spatiotemporal parameters, metabolic energy cost, and muscle activation patterns were analyzed to evaluate performance. The results demonstrate that the proposed exoskeleton effectively reduces Soleus muscle activation while increasing tibialis anterior activity, leading to a 6.84% reduction in walking energy cost compared to a nonassistive condition. Furthermore, energy recovery during the swing phase alone contributes an additional 1.67% reduction in energy expenditure, improving overall walking efficiency. The proposed design also eliminates complex clutch components, significantly simplifying manufacturing and reducing costs, thereby enhancing the applicability of passive exoskeletons in daily mobility and rehabilitation scenarios.

一种轻型被动踝关节外骨骼,具有双相能量收集和刚度适应。
被动式外骨骼具有设计轻便、结构简单、节能等优点。大多数现有的被动式外骨骼依靠离合器机制来控制基于弹簧的能量储存和释放,通常只关注步态站立阶段的生物力学能量恢复。在这项研究中,我们提出并分析了一种轻便的被动踝关节外骨骼,该外骨骼能够在站立和摆动行走阶段收集和释放能量。该装置旨在增强步态辅助,同时保持结构的简单性和最小化重量。通过将肌肉骨骼模型仿真得出的姿态和摆动阶段之间的最佳刚度比与先前建立的最佳姿态阶段刚度参数相结合,我们确定了摆动阶段弹簧的合适刚度系数。为了验证设计,我们对参与者进行了配置不同刚度系数的外骨骼行走的比较实验。分析了时空参数、代谢能量消耗和肌肉激活模式来评估性能。结果表明,拟议的外骨骼有效地减少了比目鱼肌的激活,同时增加了胫骨前肌的活动,与非辅助条件相比,步行能量消耗减少了6.84%。此外,仅在摇摆阶段的能量回收就能额外减少1.67%的能量消耗,提高整体行走效率。该设计还消除了复杂的离合器部件,大大简化了制造过程并降低了成本,从而增强了被动式外骨骼在日常移动和康复场景中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书