Mask R-CNN-based carotid plaque localization in ultrasound images.

IF 2.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Journal of Medical Imaging Pub Date : 2026-07-01 Epub Date: 2026-08-06 DOI:10.1117/1.JMI.13.4.044001
Maxwell J Kiernan, Rashid Al Mukaddim, Carol C Mitchell, Jenna Maybock, Stephanie M Wilbrand, Robert J Dempsey, Tomy Varghese
{"title":"Mask R-CNN-based carotid plaque localization in ultrasound images.","authors":"Maxwell J Kiernan, Rashid Al Mukaddim, Carol C Mitchell, Jenna Maybock, Stephanie M Wilbrand, Robert J Dempsey, Tomy Varghese","doi":"10.1117/1.JMI.13.4.044001","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In this study, we present the refinement of a Mask R-CNN model initially designed for carotid lumen detection to automatically generate bounding boxes (BB) enclosing atherosclerotic plaque. Although the model also produces segmentation masks within these bounding boxes, this study primarily evaluates bounding box detection performance as the key step to support segmentation in our ultrasound elastography workflow.</p><p><strong>Approach: </strong>We utilize a PyTorch torchvision implementation of Mask R-CNN for carotid plaque detection and BB placement. Our dataset consists of 118 severe stenotic carotid plaques from patients clinically indicated for carotid endarterectomy. Due to variability plaque presentation, different R-CNN models showed varying results based on the allowed number of prediction regions. An overview analysis of shared predictions from these models showed slight improvement over individual model results.</p><p><strong>Results: </strong>Using bounding box detection as the primary endpoint, we achieved a maximum Dice similarity coefficient (DSC) of 0.74 and intersection over union (IoU) of 0.61 for the best-performing model, with a filtered multimodel approach improving DSC to 0.76. The corresponding plaque mask segmentation performance was lower ( <math><mrow><mi>DSC</mi> <mo>=</mo> <mn>0.64</mn></mrow> </math> , <math><mrow><mi>IoU</mi> <mo>=</mo> <mn>0.49</mn></mrow> </math> ), reflecting the increased difficulty of precise plaque delineation.</p><p><strong>Conclusion: </strong>Due to significant variation in plaque presentation and types among patients, the accuracy of the Plaque Mask R-CNN network would benefit from incorporating additional patient datasets to increase variation in the training data.</p>","PeriodicalId":47707,"journal":{"name":"Journal of Medical Imaging","volume":"13 4","pages":"044001"},"PeriodicalIF":2.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13446570/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JMI.13.4.044001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: In this study, we present the refinement of a Mask R-CNN model initially designed for carotid lumen detection to automatically generate bounding boxes (BB) enclosing atherosclerotic plaque. Although the model also produces segmentation masks within these bounding boxes, this study primarily evaluates bounding box detection performance as the key step to support segmentation in our ultrasound elastography workflow.

Approach: We utilize a PyTorch torchvision implementation of Mask R-CNN for carotid plaque detection and BB placement. Our dataset consists of 118 severe stenotic carotid plaques from patients clinically indicated for carotid endarterectomy. Due to variability plaque presentation, different R-CNN models showed varying results based on the allowed number of prediction regions. An overview analysis of shared predictions from these models showed slight improvement over individual model results.

Results: Using bounding box detection as the primary endpoint, we achieved a maximum Dice similarity coefficient (DSC) of 0.74 and intersection over union (IoU) of 0.61 for the best-performing model, with a filtered multimodel approach improving DSC to 0.76. The corresponding plaque mask segmentation performance was lower ( DSC = 0.64 , IoU = 0.49 ), reflecting the increased difficulty of precise plaque delineation.

Conclusion: Due to significant variation in plaque presentation and types among patients, the accuracy of the Plaque Mask R-CNN network would benefit from incorporating additional patient datasets to increase variation in the training data.

超声图像中基于r - cnn的颈动脉斑块定位。
目的:在这项研究中,我们提出了一个Mask R-CNN模型的改进,该模型最初设计用于颈动脉管腔检测,以自动生成包围动脉粥样硬化斑块的边界框(BB)。尽管该模型也在这些边界框内产生分割掩模,但本研究主要评估边界框检测性能,将其作为超声弹性成像工作流程中支持分割的关键步骤。方法:我们利用PyTorch火炬视觉实现Mask R-CNN进行颈动脉斑块检测和BB放置。我们的数据集包括118个严重的颈动脉狭窄斑块,这些斑块来自临床指征的颈动脉内膜切除术患者。由于斑块呈现的可变性,不同的R-CNN模型根据允许的预测区域数量显示不同的结果。对来自这些模型的共享预测的总体分析显示,与单个模型的结果相比,略有改善。结果:使用边界框检测作为主要终点,我们获得了表现最佳的模型的最大Dice相似系数(DSC)为0.74,交集超过联合(IoU)为0.61,过滤的多模型方法将DSC提高到0.76。相应的斑块掩膜分割性能较低(DSC = 0.64, IoU = 0.49),反映了精确描绘斑块的难度增加。结论:由于患者的斑块表现和类型存在显著差异,斑块面罩R-CNN网络的准确性将受益于纳入额外的患者数据集,以增加训练数据的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Imaging
Journal of Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
4.20%
发文量
0
期刊介绍: JMI covers fundamental and translational research, as well as applications, focused on medical imaging, which continue to yield physical and biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal. The scope of JMI includes: Imaging physics, Tomographic reconstruction algorithms (such as those in CT and MRI), Image processing and deep learning, Computer-aided diagnosis and quantitative image analysis, Visualization and modeling, Picture archiving and communications systems (PACS), Image perception and observer performance, Technology assessment, Ultrasonic imaging, Image-guided procedures, Digital pathology, Biomedical applications of biomedical imaging. JMI allows for the peer-reviewed communication and archiving of scientific developments, translational and clinical applications, reviews, and recommendations for the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书