Clinically Relevant Blood Pressure Elevation During Apnea Testing for Brain Death Determination: Association With Circulating Catecholamines.

IF 1.9 Q3 Medicine
Korean Journal of Neurotrauma Pub Date : 2026-07-16 eCollection Date: 2026-07-01 DOI:10.13004/kjnt.2026.22.e27
Geon Hwee Jeon, Dong-Keun Hyun
{"title":"Clinically Relevant Blood Pressure Elevation During Apnea Testing for Brain Death Determination: Association With Circulating Catecholamines.","authors":"Geon Hwee Jeon, Dong-Keun Hyun","doi":"10.13004/kjnt.2026.22.e27","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To characterize hemodynamic changes during apnea testing for brain death determination and evaluate their clinical relevance while exploring associations with circulating catecholamines.</p><p><strong>Methods: </strong>We retrospectively analyzed 27 patients who underwent apnea testing between January 2020 and March 2024. Each patient underwent two apnea tests, during which heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were measured at baseline and within 1-7 minutes after testing. Peak post-test values were compared with baseline values. Plasma catecholamines were measured before and after the first test in a subset of 13 patients.</p><p><strong>Results: </strong>Both apnea tests were associated with significant increases in cardiovascular parameters. Median SBP increased from 123.5 mmHg (interquartile range [IQR], 109.2 to 142.0) to 147.5 mmHg (IQR, 128.0 to 178.8; <i>p</i><0.001). Median HR increased from 81.0 beats/min (IQR, 72.0 to 96.0) to 90.0 beats/min (IQR, 75.2 to 102.2), and DBP increased from 70.0 mmHg (IQR, 62.0 to 81.0) to 82.5 mmHg (IQR, 70.5 to 99.0) (all <i>p</i><0.001). Post-test SBP exceeded 140 mmHg and 160 mmHg in 61.1% and 38.9% of tests, respectively. Peak mean arterial pressure increased to 105.5 mmHg (IQR, 89.3 to 125.7), exceeding 90 mmHg and 100 mmHg in 72.2% and 57.4% of tests, respectively. In subset analysis, epinephrine increased modestly, whereas norepinephrine and dopamine remained unchanged.</p><p><strong>Conclusion: </strong>Apnea testing consistently induced clinically relevant increases in blood pressure and HR without corresponding elevations in circulating catecholamines, suggesting additional mechanisms may contribute to these hemodynamic responses during apnea testing.</p>","PeriodicalId":36879,"journal":{"name":"Korean Journal of Neurotrauma","volume":"22 3","pages":"220-229"},"PeriodicalIF":1.9000,"publicationDate":"2026-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13443179/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Neurotrauma","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13004/kjnt.2026.22.e27","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To characterize hemodynamic changes during apnea testing for brain death determination and evaluate their clinical relevance while exploring associations with circulating catecholamines.

Methods: We retrospectively analyzed 27 patients who underwent apnea testing between January 2020 and March 2024. Each patient underwent two apnea tests, during which heart rate (HR), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were measured at baseline and within 1-7 minutes after testing. Peak post-test values were compared with baseline values. Plasma catecholamines were measured before and after the first test in a subset of 13 patients.

Results: Both apnea tests were associated with significant increases in cardiovascular parameters. Median SBP increased from 123.5 mmHg (interquartile range [IQR], 109.2 to 142.0) to 147.5 mmHg (IQR, 128.0 to 178.8; p<0.001). Median HR increased from 81.0 beats/min (IQR, 72.0 to 96.0) to 90.0 beats/min (IQR, 75.2 to 102.2), and DBP increased from 70.0 mmHg (IQR, 62.0 to 81.0) to 82.5 mmHg (IQR, 70.5 to 99.0) (all p<0.001). Post-test SBP exceeded 140 mmHg and 160 mmHg in 61.1% and 38.9% of tests, respectively. Peak mean arterial pressure increased to 105.5 mmHg (IQR, 89.3 to 125.7), exceeding 90 mmHg and 100 mmHg in 72.2% and 57.4% of tests, respectively. In subset analysis, epinephrine increased modestly, whereas norepinephrine and dopamine remained unchanged.

Conclusion: Apnea testing consistently induced clinically relevant increases in blood pressure and HR without corresponding elevations in circulating catecholamines, suggesting additional mechanisms may contribute to these hemodynamic responses during apnea testing.

脑死亡测定呼吸暂停试验期间的临床相关血压升高:与循环儿茶酚胺的关系
目的:探讨呼吸暂停试验中血液动力学变化与循环儿茶酚胺的关系,并评价其临床意义。方法:我们回顾性分析了2020年1月至2024年3月期间接受呼吸暂停测试的27例患者。每位患者进行两次呼吸暂停测试,在基线和测试后1-7分钟内测量心率(HR)、收缩压(SBP)和舒张压(DBP)。将峰值后测值与基线值进行比较。在13名患者的第一次测试前后测量血浆儿茶酚胺。结果:两项呼吸暂停试验均与心血管参数显著升高相关。中位收压从123.5 mmHg(四分位数范围[IQR], 109.2至142.0)上升至147.5 mmHg (IQR, 128.0至178.8)。结论:呼吸暂停测试持续诱导血压和HR升高,但循环儿茶酚胺没有相应升高,提示呼吸暂停测试期间这些血流动力学反应可能有其他机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
41
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书