AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring.

IF 18.1 Q1 ENGINEERING, BIOMEDICAL
Cyborg and bionic systems (Washington, D.C.) Pub Date : 2026-08-05 eCollection Date: 2026-01-01 DOI:10.34133/cbsystems.0653
Liping Dong, Xingxuan Zhang, Meng Li, Yi Li, Jingyi Guo, Shaorong Lu, Zhenyu Peng, Chenxi Zheng, Yufei Hui, Xiaoping Shao, Feiyan Wang, Weikang Jiang, Maoyao Li, Xianshuai Wu, Xu Guo, Yingchuan Li, Yuanyi Zheng, Liping Zhang
{"title":"AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring.","authors":"Liping Dong, Xingxuan Zhang, Meng Li, Yi Li, Jingyi Guo, Shaorong Lu, Zhenyu Peng, Chenxi Zheng, Yufei Hui, Xiaoping Shao, Feiyan Wang, Weikang Jiang, Maoyao Li, Xianshuai Wu, Xu Guo, Yingchuan Li, Yuanyi Zheng, Liping Zhang","doi":"10.34133/cbsystems.0653","DOIUrl":null,"url":null,"abstract":"<p><p>Central venous pressure (CVP) is a key indicator of right ventricular preload, but measurement with a central venous catheter (CVC) is invasive, time-consuming, and unsuitable for bedside monitoring. We developed and clinically evaluated an artificial intelligence (AI)-enabled wearable ultrasound device for noninvasive estimation of elevated CVP by imaging the internal jugular vein (IJV) and common carotid artery (CCA) in acute and critical patients. In this prospective multi-center clinical study, 349 patients admitted to intensive care units (ICUs) at 2 tertiary hospitals underwent neck vascular imaging with the wearable ultrasound device, while CVP was measured simultaneously via CVC as the reference standard. The dual-decoder spatiotemporal attention network (DSTA-Net) segmentation model automatically quantified IJV and CCA cross-sectional areas, and the dual-modality multilayer perceptron (DM-MLP) integrated these vascular indices with basic clinical parameters to predict elevated CVP (≥8 mmHg). DSTA-Net showed excellent agreement and strong correlation with expert manual measurements while achieving superior segmentation accuracy compared with the baseline segmentation model. Meanwhile, the proposed DM-MLP improved prediction performance by 4% to 8% over conventional baseline architectures, achieving AUCs of 0.91 (internal test set) and 0.87 (external test set). These findings indicate that an AI-integrated wearable ultrasound device can provide accurate, noninvasive bedside assessment of CVP and may offer a promising alternative to invasive catheters for hemodynamic monitoring in acute and critical care settings.</p>","PeriodicalId":72764,"journal":{"name":"Cyborg and bionic systems (Washington, D.C.)","volume":"7 ","pages":"0653"},"PeriodicalIF":18.1000,"publicationDate":"2026-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13438027/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cyborg and bionic systems (Washington, D.C.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34133/cbsystems.0653","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Central venous pressure (CVP) is a key indicator of right ventricular preload, but measurement with a central venous catheter (CVC) is invasive, time-consuming, and unsuitable for bedside monitoring. We developed and clinically evaluated an artificial intelligence (AI)-enabled wearable ultrasound device for noninvasive estimation of elevated CVP by imaging the internal jugular vein (IJV) and common carotid artery (CCA) in acute and critical patients. In this prospective multi-center clinical study, 349 patients admitted to intensive care units (ICUs) at 2 tertiary hospitals underwent neck vascular imaging with the wearable ultrasound device, while CVP was measured simultaneously via CVC as the reference standard. The dual-decoder spatiotemporal attention network (DSTA-Net) segmentation model automatically quantified IJV and CCA cross-sectional areas, and the dual-modality multilayer perceptron (DM-MLP) integrated these vascular indices with basic clinical parameters to predict elevated CVP (≥8 mmHg). DSTA-Net showed excellent agreement and strong correlation with expert manual measurements while achieving superior segmentation accuracy compared with the baseline segmentation model. Meanwhile, the proposed DM-MLP improved prediction performance by 4% to 8% over conventional baseline architectures, achieving AUCs of 0.91 (internal test set) and 0.87 (external test set). These findings indicate that an AI-integrated wearable ultrasound device can provide accurate, noninvasive bedside assessment of CVP and may offer a promising alternative to invasive catheters for hemodynamic monitoring in acute and critical care settings.

用于无创中心静脉压监测的人工智能可穿戴超声。
中心静脉压(CVP)是右心室预负荷的关键指标,但使用中心静脉导管(CVC)测量是有创的,耗时的,不适合床边监测。我们开发并临床评估了一种人工智能(AI)支持的可穿戴超声设备,用于通过对急性和危重患者的颈内静脉(IJV)和颈总动脉(CCA)成像来无创评估CVP升高。本前瞻性多中心临床研究选取2所三级医院重症监护病房(icu) 349例患者,采用可穿戴式超声设备进行颈部血管成像,同时以CVC作为参比标准测量CVP。双解码器时空注意网络(DSTA-Net)分割模型自动量化IJV和CCA横截面积,双模态多层感知器(DM-MLP)将这些血管指标与基本临床参数相结合,预测CVP升高(≥8 mmHg)。与基线分割模型相比,DSTA-Net与专家手工测量结果具有良好的一致性和强相关性,同时具有更高的分割精度。与此同时,所提出的DM-MLP预测性能比传统基准架构提高了4%至8%,实现了0.91(内部测试集)和0.87(外部测试集)的auc。这些研究结果表明,人工智能集成的可穿戴超声设备可以提供准确、无创的CVP床边评估,并可能为急性和危重监护环境中的血流动力学监测提供有创导管的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.70
自引率
0.00%
发文量
0
审稿时长
21 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书