Digital Therapeutics for Postoperative Rehabilitation after Arthroscopic Rotator Cuff Repair: A Single-Center, Assessor-Blinded, Randomized Pilot Study.

IF 2.5 2区 医学 Q2 ORTHOPEDICS
Clinics in Orthopedic Surgery Pub Date : 2026-08-01 Epub Date: 2026-03-26 DOI:10.4055/cios25474
So-Youn Chang, Jong-Ho Kim, Youn Kyu Lee, Hyun Tae Shin, Chul Ho Lee, Su Jeong Lee, Hong Kwon Lee, Min Jeon, Eun-Ji Yoon
{"title":"Digital Therapeutics for Postoperative Rehabilitation after Arthroscopic Rotator Cuff Repair: A Single-Center, Assessor-Blinded, Randomized Pilot Study.","authors":"So-Youn Chang, Jong-Ho Kim, Youn Kyu Lee, Hyun Tae Shin, Chul Ho Lee, Su Jeong Lee, Hong Kwon Lee, Min Jeon, Eun-Ji Yoon","doi":"10.4055/cios25474","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Home-based rehabilitation after arthroscopic rotator cuff repair (ARCR) often lacks objective monitoring. To address this limitation, we developed the ANAPA digital rehabilitation (DR) system, which includes a patient-facing mobile application for clinical efficacy evaluation (ANAPA ME) and a physician-facing measurement application for technical assessment (ANAPA PS). This study compared the safety and preliminary efficacy of ANAPA ME with conventional YouTube-based rehabilitation (CR), with an additional validation of the automated measurement functions in ANAPA PS.</p><p><strong>Methods: </strong>This single-center, assessor-blinded, randomized pilot study included 18 patients who had undergone ARCR. The participants were allocated to the DR group (n = 9) or CR group (n = 9) and followed identical postoperative rotator cuff exercise protocols. The program was conducted for 24 weeks postoperatively. The shoulder range of motion (ROM), muscle strength, and clinical outcomes (visual analog scale pain score, Constant shoulder score, Shoulder Pain and Disability Index, and EuroQol-5 Dimension-5 Level questionnaire) were evaluated at baseline and at follow-up up to 24 weeks postoperatively. Ultrasonography was performed at 24 weeks to evaluate the integrity of the repaired tendons. Automated ROM and muscle strength measurements of ANAPA PS were validated against digital goniometry and hand-held dynamometry at the 6-month follow-up, and measurement consistency was assessed using intraclass correlation coefficients (ICCs) and coefficients of variation (CV).</p><p><strong>Results: </strong>Both the DR and CR groups demonstrated significant within-group improvements in ROM and clinical scores (<i>p</i> < 0.05). The DR group showed significantly greater improvements in specific ROM parameters, including forward flexion at 24 weeks and abduction, abduction-external rotation, and internal rotation at 18 and 24 weeks, compared with the CR group (<i>p</i> < 0.05). At 18 weeks, the internal rotation muscle strength was also significantly higher in the DR group than in the CR group (<i>p</i> < 0.05). A significant time-by-group interaction was observed for abduction, side-external rotation, and internal rotation (<i>p</i> < 0.05), suggesting a more consistent improvement pattern over time in the DR group compared with the CR group. In supplementary validation, ANAPA PS measurements showed high agreement with reference instruments (mean absolute error of 3.14° for ROM and 0.15-0.22 kgf for muscle strength). In consistency analysis, ANAPA PS showed higher repeatability and lower variability than digital goniometry (ICC = 0.99 vs. 0.97; CV = 1.61% vs. 11.7%, <i>p</i> < 0.001) and hand-held dynamometry (ICC = 0.97 vs. 0.39; CV = 2.1% vs. 13.8%, <i>p</i> < 0.001).</p><p><strong>Conclusions: </strong>In this exploratory pilot study, the ANAPA DR system demonstrated favorable trends compared with CR in patients after ARCR, suggesting the feasibility and safety of artificial intelligence-based digital therapeutics in postoperative shoulder rehabilitation. The supplementary validation further demonstrated the technical reliability and measurement consistency of the ANAPA PS automated measurement functions for monitoring rehabilitation outcomes.</p>","PeriodicalId":47648,"journal":{"name":"Clinics in Orthopedic Surgery","volume":"18 4","pages":"708-721"},"PeriodicalIF":2.5000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13437144/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics in Orthopedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4055/cios25474","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Home-based rehabilitation after arthroscopic rotator cuff repair (ARCR) often lacks objective monitoring. To address this limitation, we developed the ANAPA digital rehabilitation (DR) system, which includes a patient-facing mobile application for clinical efficacy evaluation (ANAPA ME) and a physician-facing measurement application for technical assessment (ANAPA PS). This study compared the safety and preliminary efficacy of ANAPA ME with conventional YouTube-based rehabilitation (CR), with an additional validation of the automated measurement functions in ANAPA PS.

Methods: This single-center, assessor-blinded, randomized pilot study included 18 patients who had undergone ARCR. The participants were allocated to the DR group (n = 9) or CR group (n = 9) and followed identical postoperative rotator cuff exercise protocols. The program was conducted for 24 weeks postoperatively. The shoulder range of motion (ROM), muscle strength, and clinical outcomes (visual analog scale pain score, Constant shoulder score, Shoulder Pain and Disability Index, and EuroQol-5 Dimension-5 Level questionnaire) were evaluated at baseline and at follow-up up to 24 weeks postoperatively. Ultrasonography was performed at 24 weeks to evaluate the integrity of the repaired tendons. Automated ROM and muscle strength measurements of ANAPA PS were validated against digital goniometry and hand-held dynamometry at the 6-month follow-up, and measurement consistency was assessed using intraclass correlation coefficients (ICCs) and coefficients of variation (CV).

Results: Both the DR and CR groups demonstrated significant within-group improvements in ROM and clinical scores (p < 0.05). The DR group showed significantly greater improvements in specific ROM parameters, including forward flexion at 24 weeks and abduction, abduction-external rotation, and internal rotation at 18 and 24 weeks, compared with the CR group (p < 0.05). At 18 weeks, the internal rotation muscle strength was also significantly higher in the DR group than in the CR group (p < 0.05). A significant time-by-group interaction was observed for abduction, side-external rotation, and internal rotation (p < 0.05), suggesting a more consistent improvement pattern over time in the DR group compared with the CR group. In supplementary validation, ANAPA PS measurements showed high agreement with reference instruments (mean absolute error of 3.14° for ROM and 0.15-0.22 kgf for muscle strength). In consistency analysis, ANAPA PS showed higher repeatability and lower variability than digital goniometry (ICC = 0.99 vs. 0.97; CV = 1.61% vs. 11.7%, p < 0.001) and hand-held dynamometry (ICC = 0.97 vs. 0.39; CV = 2.1% vs. 13.8%, p < 0.001).

Conclusions: In this exploratory pilot study, the ANAPA DR system demonstrated favorable trends compared with CR in patients after ARCR, suggesting the feasibility and safety of artificial intelligence-based digital therapeutics in postoperative shoulder rehabilitation. The supplementary validation further demonstrated the technical reliability and measurement consistency of the ANAPA PS automated measurement functions for monitoring rehabilitation outcomes.

关节镜下肩袖修复术后康复的数字治疗:一项单中心、评估盲、随机试验研究。
背景:关节镜下肩袖修复(ARCR)后的家庭康复往往缺乏客观的监测。为了解决这一限制,我们开发了ANAPA数字康复(DR)系统,其中包括一个面向患者的临床疗效评估移动应用程序(ANAPA ME)和一个面向医生的技术评估测量应用程序(ANAPA PS)。本研究比较了ANAPA ME与传统的基于youtube的康复(CR)的安全性和初步疗效,并对ANAPA ps的自动测量功能进行了额外的验证。方法:这项单中心、评估盲、随机试验研究纳入了18例接受过ARCR的患者。参与者被分配到DR组(n = 9)或CR组(n = 9),并遵循相同的术后肩袖运动方案。术后随访24周。在基线和术后24周随访时评估肩部活动度(ROM)、肌肉力量和临床结果(视觉模拟疼痛评分、肩部恒定评分、肩部疼痛和残疾指数以及EuroQol-5维度-5水平问卷)。在24周时进行超声检查以评估修复肌腱的完整性。在6个月的随访中,ANAPA PS的自动ROM和肌肉力量测量与数字测角仪和手持式测力仪进行了验证,并使用类内相关系数(ICCs)和变异系数(CV)评估测量的一致性。结果:DR组和CR组在ROM和临床评分方面均有显著改善(p < 0.05)。与CR组相比,DR组在特定ROM参数方面表现出更大的改善,包括24周时的前屈,18周和24周时的外展、外展-外旋和内旋(p < 0.05)。在18周时,DR组内旋肌力也显著高于CR组(p < 0.05)。观察到外展、侧外旋和内旋的显著时间组相互作用(p < 0.05),表明DR组与CR组相比,随着时间的推移有更一致的改善模式。在补充验证中,ANAPA PS测量结果显示与参考仪器高度一致(ROM的平均绝对误差为3.14°,肌肉力量的平均绝对误差为0.15-0.22 kgf)。在一致性分析中,ANAPA PS比数字测角仪(ICC = 0.99 vs. 0.97; CV = 1.61% vs. 11.7%, p < 0.001)和手持式测力仪(ICC = 0.97 vs. 0.39; CV = 2.1% vs. 13.8%, p < 0.001)具有更高的重复性和更低的可变性。结论:在本探索性先导研究中,ANAPA DR系统在ARCR患者中表现出较CR有利的趋势,提示基于人工智能的数字治疗在肩关节术后康复中的可行性和安全性。补充验证进一步验证了ANAPA PS自动测量功能监测康复结局的技术可靠性和测量一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.50
自引率
4.00%
发文量
85
审稿时长
36 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书