Nivedhitha Govindasamy, William S Tuten, David H Brainard, Jessica I W Morgan
{"title":"Repeatability of Foveal Sensitivity Measured Using Adaptive Optics Microperimetry.","authors":"Nivedhitha Govindasamy, William S Tuten, David H Brainard, Jessica I W Morgan","doi":"10.1167/tvst.15.8.3","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the within and between-session repeatability of foveal sensitivity measurements using adaptive optics (AO) microperimetry.</p><p><strong>Methods: </strong>Five normal-sighted participants underwent AO microperimetry testing (550-nm circular stimulus) at the preferred retinal locus across two sessions (2 months ± 2 weeks). Two psychophysical paradigms were used: quick estimation of threshold (QUEST) and method of constant stimuli (MOCS). Each paradigm employed both 1.05-arcmin2 and 30.4-arcmin2 stimulus sizes; stimuli were not stabilized in real time. Trial-by-trial responses were fit with a logistic psychometric function to obtain thresholds at a criterion of 78% seen. Thresholds were converted to sensitivity. Statistical comparisons were performed using paired-sample t-tests.</p><p><strong>Results: </strong>Sensitivities measured from QUEST and MOCS procedures were not significantly different (QUEST: 1.05 arcmin2, P = 0.36 for session 1 and P = 0.41 for session 2; MOCS: 30.4 arcmin2, P = 0.14 for session 1 and P = 0.12 for session 2). Data were thus combined across paradigms for tests of repeatability. Sensitivities for data split into two groups within session 1 and separately within session 2 were not significantly different (QUEST: 1.05 arcmin2, P = 0.34 for session 1 and P = 0.51 for session 2; MOCS: 30.4 arcmin2, P = 0.31 for session 1 and P = 0.27 for session 2). Overall, sensitivities across the two sessions were not significantly different (QUEST: 1.05 arcmin2, P = 0.06; MOCS: 30.4 arcmin2, P = 0.81). The coefficients of repeatability across sessions were 1.5 decibels (dB) and 0.4 dB for 1.05 arcmin2 and 30.4 arcmin2, respectively.</p><p><strong>Conclusions: </strong>Sensitivity measurements from AO microperimetry were repeatable within and across sessions.</p><p><strong>Translational relevance: </strong>Results of the present study will guide future longitudinal studies of disease progression in detecting sensitivity changes using AO microperimetry.</p>","PeriodicalId":23322,"journal":{"name":"Translational Vision Science & Technology","volume":"15 8","pages":"3"},"PeriodicalIF":2.7000,"publicationDate":"2026-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13450651/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational Vision Science & Technology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1167/tvst.15.8.3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To assess the within and between-session repeatability of foveal sensitivity measurements using adaptive optics (AO) microperimetry.
Methods: Five normal-sighted participants underwent AO microperimetry testing (550-nm circular stimulus) at the preferred retinal locus across two sessions (2 months ± 2 weeks). Two psychophysical paradigms were used: quick estimation of threshold (QUEST) and method of constant stimuli (MOCS). Each paradigm employed both 1.05-arcmin2 and 30.4-arcmin2 stimulus sizes; stimuli were not stabilized in real time. Trial-by-trial responses were fit with a logistic psychometric function to obtain thresholds at a criterion of 78% seen. Thresholds were converted to sensitivity. Statistical comparisons were performed using paired-sample t-tests.
Results: Sensitivities measured from QUEST and MOCS procedures were not significantly different (QUEST: 1.05 arcmin2, P = 0.36 for session 1 and P = 0.41 for session 2; MOCS: 30.4 arcmin2, P = 0.14 for session 1 and P = 0.12 for session 2). Data were thus combined across paradigms for tests of repeatability. Sensitivities for data split into two groups within session 1 and separately within session 2 were not significantly different (QUEST: 1.05 arcmin2, P = 0.34 for session 1 and P = 0.51 for session 2; MOCS: 30.4 arcmin2, P = 0.31 for session 1 and P = 0.27 for session 2). Overall, sensitivities across the two sessions were not significantly different (QUEST: 1.05 arcmin2, P = 0.06; MOCS: 30.4 arcmin2, P = 0.81). The coefficients of repeatability across sessions were 1.5 decibels (dB) and 0.4 dB for 1.05 arcmin2 and 30.4 arcmin2, respectively.
Conclusions: Sensitivity measurements from AO microperimetry were repeatable within and across sessions.
Translational relevance: Results of the present study will guide future longitudinal studies of disease progression in detecting sensitivity changes using AO microperimetry.
期刊介绍:
Translational Vision Science & Technology (TVST), an official journal of the Association for Research in Vision and Ophthalmology (ARVO), an international organization whose purpose is to advance research worldwide into understanding the visual system and preventing, treating and curing its disorders, is an online, open access, peer-reviewed journal emphasizing multidisciplinary research that bridges the gap between basic research and clinical care. A highly qualified and diverse group of Associate Editors and Editorial Board Members is led by Editor-in-Chief Marco Zarbin, MD, PhD, FARVO.
The journal covers a broad spectrum of work, including but not limited to:
Applications of stem cell technology for regenerative medicine,
Development of new animal models of human diseases,
Tissue bioengineering,
Chemical engineering to improve virus-based gene delivery,
Nanotechnology for drug delivery,
Design and synthesis of artificial extracellular matrices,
Development of a true microsurgical operating environment,
Refining data analysis algorithms to improve in vivo imaging technology,
Results of Phase 1 clinical trials,
Reverse translational ("bedside to bench") research.
TVST seeks manuscripts from scientists and clinicians with diverse backgrounds ranging from basic chemistry to ophthalmic surgery that will advance or change the way we understand and/or treat vision-threatening diseases. TVST encourages the use of color, multimedia, hyperlinks, program code and other digital enhancements.