To what extent can bowel preparation quality be considered "adequate"?: a systematic review and meta-analysis.

IF 3.4 Q3 GASTROENTEROLOGY & HEPATOLOGY
Clinical Endoscopy Pub Date : 2026-07-01 Epub Date: 2026-07-30 DOI:10.5946/ce.2026.022
Chen-Ya Kuo, David Karsenti, Salvador Machlab, Fu-Jen Lee, Yu-Tsung Chen, Te-Ling Ma, Chi-Yang Chang, Yu-Tse Chiu
{"title":"To what extent can bowel preparation quality be considered \"adequate\"?: a systematic review and meta-analysis.","authors":"Chen-Ya Kuo, David Karsenti, Salvador Machlab, Fu-Jen Lee, Yu-Tsung Chen, Te-Ling Ma, Chi-Yang Chang, Yu-Tse Chiu","doi":"10.5946/ce.2026.022","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>While low-quality bowel preparation is known to reduce the adenoma detection rate (ADR), the distinction between intermediate- and high-quality preparations remains unclear.</p><p><strong>Methods: </strong>Electronic searches were conducted in PubMed and Embase through July 2024. Randomized controlled trials reporting ADR and the Boston bowel preparation scale (BBPS) were included, and outcomes were pooled according to bowel preparation quality using a random-effects model. The primary outcome was ADR in intermediate-quality (BBPS ≥6, and ≥2 in each segment) versus high-quality (BBPS≥8) bowel preparation. Secondary outcomes included advanced ADR.</p><p><strong>Results: </strong>Fourteen trials were included (5,246 in the high-quality group and 1,728 in the other group). There was no significant difference in ADR (risk difference [RD], -0.02; p=0.13; I2=21%). Subgroup analyses showed no significant difference with computer-aided detection (CADe; RD, -0.03; p=0.70; I2=81%) or linked color imaging (RD, 0.04; p=0.31; I2=0%). The heterogeneity observed with CADe may reflect differences in colonoscopist experience or CADe systems. The results were similar for advanced ADR. Funnel plot and Egger's test indicated minimal publication bias.</p><p><strong>Conclusions: </strong>Intermediate-quality preparation allows adequate adenoma detection. When each BBPS subscore is ≥2, surveillance recommendations can generally be followed.</p>","PeriodicalId":10351,"journal":{"name":"Clinical Endoscopy","volume":"59 4","pages":"569-580"},"PeriodicalIF":3.4000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13439292/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5946/ce.2026.022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: While low-quality bowel preparation is known to reduce the adenoma detection rate (ADR), the distinction between intermediate- and high-quality preparations remains unclear.

Methods: Electronic searches were conducted in PubMed and Embase through July 2024. Randomized controlled trials reporting ADR and the Boston bowel preparation scale (BBPS) were included, and outcomes were pooled according to bowel preparation quality using a random-effects model. The primary outcome was ADR in intermediate-quality (BBPS ≥6, and ≥2 in each segment) versus high-quality (BBPS≥8) bowel preparation. Secondary outcomes included advanced ADR.

Results: Fourteen trials were included (5,246 in the high-quality group and 1,728 in the other group). There was no significant difference in ADR (risk difference [RD], -0.02; p=0.13; I2=21%). Subgroup analyses showed no significant difference with computer-aided detection (CADe; RD, -0.03; p=0.70; I2=81%) or linked color imaging (RD, 0.04; p=0.31; I2=0%). The heterogeneity observed with CADe may reflect differences in colonoscopist experience or CADe systems. The results were similar for advanced ADR. Funnel plot and Egger's test indicated minimal publication bias.

Conclusions: Intermediate-quality preparation allows adequate adenoma detection. When each BBPS subscore is ≥2, surveillance recommendations can generally be followed.

肠准备的质量在什么程度上可以被认为是“适当的”?:系统回顾和荟萃分析。
背景:虽然已知低质量的肠准备可降低腺瘤检出率(ADR),但中等质量和高质量的肠准备之间的区别尚不清楚。方法:截止2024年7月在PubMed和Embase进行电子检索。纳入报告不良反应和波士顿肠准备量表(BBPS)的随机对照试验,并使用随机效应模型根据肠准备质量汇总结果。主要结局是中等质量(BBPS≥6,各节段均≥2)与高质量(BBPS≥8)肠道准备的不良反应。次要结局包括严重不良反应。结果:纳入14项试验(高质量组5246项,低质量组1728项)。两组不良反应发生率差异无统计学意义(风险差[RD], -0.02; p=0.13; I2=21%)。亚组分析显示,计算机辅助检测(CADe; RD, -0.03; p=0.70; I2=81%)或关联彩色成像(RD, 0.04; p=0.31; I2=0%)无显著差异。CADe观察到的异质性可能反映了结肠镜医师经验或CADe系统的差异。晚期不良反应的结果相似。漏斗图和Egger检验显示发表偏倚最小。结论:中等质量的准备可以充分检测腺瘤。当每个BBPS分值≥2时,一般可以遵循监测建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Endoscopy
Clinical Endoscopy GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
4.40
自引率
8.00%
发文量
95
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书