{"title":"Diagnostic Accuracy and Optimal Thresholds of Salivary Pepsin (Peptest) in Laryngopharyngeal Reflux: A Systematic Review and Meta-Analysis","authors":"Do Hyun Kim, David W. Jang, Se Hwan Hwang","doi":"10.1111/coa.70154","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>Salivary pepsin has been proposed as a non-invasive biomarker for diagnosing laryngopharyngeal reflux (LPR); however, its diagnostic utility remains uncertain due to inconsistent findings across studies. This meta-analysis evaluated the diagnostic accuracy of a rapid lateral flow test (Peptest) compared to the reference standard of multichannel intraluminal impedance-pH (MII-pH) monitoring.</p>\n </section>\n \n <section>\n \n <h3> Design and Setting</h3>\n \n <p>Systematic review and meta-analysis of cohort studies.</p>\n </section>\n \n <section>\n \n <h3> Participants</h3>\n \n <p>Patients with LPR.</p>\n </section>\n \n <section>\n \n <h3> Main Outcome Measures</h3>\n \n <p>The primary outcomes were diagnostic odds ratio (DOR), summary receiver operating characteristic curve and area under the curve (AUC).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>In total, 11 studies comprising 928 samples were included. The diagnostic performance of salivary pepsin for LPR was analysed at cut-off values of 16, 45–50 and 100 ng/mL. The pooled DOR and AUC were 3.49 and 0.684 at 16 ng/mL, 6.08 and 0.772 at 45–50 ng/mL and 4.78 and 0.717 at 100 ng/mL, respectively. Multiple-time sampling significantly improved sensitivity compared to single-time sampling across all cut-off values (0.82 vs. 0.33–0.63 at 16 ng/mL; <i>p</i> < 0.0001), although specificity was slightly lower.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The Peptest demonstrates potential as a simple, non-invasive diagnostic alternative to 24-h-MII-pH monitoring for LPR. Among the evaluated thresholds, a cut-off of 45–50 ng/mL provided the highest diagnostic accuracy. Collecting multiple saliva samples may further enhance detection sensitivity. However, in patients with a high clinical suspicion of LPR but negative Peptest results, 24-h-MII-pH monitoring remains necessary to confirm the diagnosis due to the test's limited negative predictive value.</p>\n </section>\n </div>","PeriodicalId":10431,"journal":{"name":"Clinical Otolaryngology","volume":"51 6","pages":"819-830"},"PeriodicalIF":1.9000,"publicationDate":"2026-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Otolaryngology","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/coa.70154","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
Salivary pepsin has been proposed as a non-invasive biomarker for diagnosing laryngopharyngeal reflux (LPR); however, its diagnostic utility remains uncertain due to inconsistent findings across studies. This meta-analysis evaluated the diagnostic accuracy of a rapid lateral flow test (Peptest) compared to the reference standard of multichannel intraluminal impedance-pH (MII-pH) monitoring.
Design and Setting
Systematic review and meta-analysis of cohort studies.
Participants
Patients with LPR.
Main Outcome Measures
The primary outcomes were diagnostic odds ratio (DOR), summary receiver operating characteristic curve and area under the curve (AUC).
Results
In total, 11 studies comprising 928 samples were included. The diagnostic performance of salivary pepsin for LPR was analysed at cut-off values of 16, 45–50 and 100 ng/mL. The pooled DOR and AUC were 3.49 and 0.684 at 16 ng/mL, 6.08 and 0.772 at 45–50 ng/mL and 4.78 and 0.717 at 100 ng/mL, respectively. Multiple-time sampling significantly improved sensitivity compared to single-time sampling across all cut-off values (0.82 vs. 0.33–0.63 at 16 ng/mL; p < 0.0001), although specificity was slightly lower.
Conclusions
The Peptest demonstrates potential as a simple, non-invasive diagnostic alternative to 24-h-MII-pH monitoring for LPR. Among the evaluated thresholds, a cut-off of 45–50 ng/mL provided the highest diagnostic accuracy. Collecting multiple saliva samples may further enhance detection sensitivity. However, in patients with a high clinical suspicion of LPR but negative Peptest results, 24-h-MII-pH monitoring remains necessary to confirm the diagnosis due to the test's limited negative predictive value.
期刊介绍:
Clinical Otolaryngology is a bimonthly journal devoted to clinically-oriented research papers of the highest scientific standards dealing with:
current otorhinolaryngological practice
audiology, otology, balance, rhinology, larynx, voice and paediatric ORL
head and neck oncology
head and neck plastic and reconstructive surgery
continuing medical education and ORL training
The emphasis is on high quality new work in the clinical field and on fresh, original research.
Each issue begins with an editorial expressing the personal opinions of an individual with a particular knowledge of a chosen subject. The main body of each issue is then devoted to original papers carrying important results for those working in the field. In addition, topical review articles are published discussing a particular subject in depth, including not only the opinions of the author but also any controversies surrounding the subject.
• Negative/null results
In order for research to advance, negative results, which often make a valuable contribution to the field, should be published. However, articles containing negative or null results are frequently not considered for publication or rejected by journals. We welcome papers of this kind, where appropriate and valid power calculations are included that give confidence that a negative result can be relied upon.