{"title":"Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties","authors":"Hidekazu Yasunaga, Yoshihiko Tashiro, Shinji Ando","doi":"10.1038/s41428-026-01170-9","DOIUrl":null,"url":null,"abstract":"A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10–4 mol L–1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness. A near-infrared fluorescent surgical gauze was developed by dyeing cotton with indocyanine green (ICG) using an autoclave at 121–132 °C and 0.21–0.29 MPa. The optimal condition (1.5 × 10⁻⁴ mol L–1 ICG, 132 °C, 10–15 min) yielded the brightest fluorescence. Post-sterilization (PS) enhanced fluorescence by dissolving ICG aggregates and improving fixation. The gauze’s color remained similar to undyed samples, but fluorescence increased by post-sterilization. It emitted strong NIR signals through over 10 mm of tissue and showed minimal dye leakage in artificial body fluid, making it useful for surgical site identification and reducing gauze remnants.","PeriodicalId":20302,"journal":{"name":"Polymer Journal","volume":"58 8","pages":"963-973"},"PeriodicalIF":3.1000,"publicationDate":"2026-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.comhttps://www.nature.com/articles/s41428-026-01170-9.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymer Journal","FirstCategoryId":"92","ListUrlMain":"https://www.nature.com/articles/s41428-026-01170-9","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0
Abstract
A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10–4 mol L–1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness. A near-infrared fluorescent surgical gauze was developed by dyeing cotton with indocyanine green (ICG) using an autoclave at 121–132 °C and 0.21–0.29 MPa. The optimal condition (1.5 × 10⁻⁴ mol L–1 ICG, 132 °C, 10–15 min) yielded the brightest fluorescence. Post-sterilization (PS) enhanced fluorescence by dissolving ICG aggregates and improving fixation. The gauze’s color remained similar to undyed samples, but fluorescence increased by post-sterilization. It emitted strong NIR signals through over 10 mm of tissue and showed minimal dye leakage in artificial body fluid, making it useful for surgical site identification and reducing gauze remnants.
期刊介绍:
Polymer Journal promotes research from all aspects of polymer science from anywhere in the world and aims to provide an integrated platform for scientific communication that assists the advancement of polymer science and related fields. The journal publishes Original Articles, Notes, Short Communications and Reviews.
Subject areas and topics of particular interest within the journal''s scope include, but are not limited to, those listed below:
Polymer synthesis and reactions
Polymer structures
Physical properties of polymers
Polymer surface and interfaces
Functional polymers
Supramolecular polymers
Self-assembled materials
Biopolymers and bio-related polymer materials
Polymer engineering.