Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties

IF 3.1 4区 化学 Q3 POLYMER SCIENCE
Hidekazu Yasunaga, Yoshihiko Tashiro, Shinji Ando
{"title":"Preparation of surgical indocyanine green-dyed gauze using an autoclave and its near-infrared fluorescence properties","authors":"Hidekazu Yasunaga, Yoshihiko Tashiro, Shinji Ando","doi":"10.1038/s41428-026-01170-9","DOIUrl":null,"url":null,"abstract":"A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10–4 mol L–1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness. A near-infrared fluorescent surgical gauze was developed by dyeing cotton with indocyanine green (ICG) using an autoclave at 121–132 °C and 0.21–0.29 MPa. The optimal condition (1.5 × 10⁻⁴ mol L–1 ICG, 132 °C, 10–15 min) yielded the brightest fluorescence. Post-sterilization (PS) enhanced fluorescence by dissolving ICG aggregates and improving fixation. The gauze’s color remained similar to undyed samples, but fluorescence increased by post-sterilization. It emitted strong NIR signals through over 10 mm of tissue and showed minimal dye leakage in artificial body fluid, making it useful for surgical site identification and reducing gauze remnants.","PeriodicalId":20302,"journal":{"name":"Polymer Journal","volume":"58 8","pages":"963-973"},"PeriodicalIF":3.1000,"publicationDate":"2026-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.nature.comhttps://www.nature.com/articles/s41428-026-01170-9.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polymer Journal","FirstCategoryId":"92","ListUrlMain":"https://www.nature.com/articles/s41428-026-01170-9","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0

Abstract

A near-infrared (NIR)-fluorescent gauze dyed with indocyanine green (ICG) was newly developed using an autoclave to prevent gauze remnants and serve as a landmark for rapid identification of the target area during surgery. The gauze samples were dyed with an aqueous ICG solution at variable concentrations at high temperatures of 121 − 132 °C and high water vapor pressures of 0.21 − 0.29 MPa to enhance NIR fluorescence (FL) and increase dyeability and fastness. The gauze dyed with an ICG concentration of 1.5 × 10–4 mol L–1 at 132 °C for 10–15 min exhibited the brightest FL, with a quantum yield of 3.9%. Although the color of the dyed gauze was nearly identical to that of undyed gauze, as estimated by optical density and K/S value, the FL intensity further increased after post-sterilization (PS) at 132 °C for 8 min. This enhancement was attributed to the dissolution of ICG aggregates and improved fixation on the cotton fibers. Furthermore, the high-temperature dyeing technique followed by PS effectively suppressed ICG leakage from the gauze when soaked in artificial body fluid. The NIR-FL emitted from the gauze was clearly observed through human tissue, approximately 10 mm or more in thickness. A near-infrared fluorescent surgical gauze was developed by dyeing cotton with indocyanine green (ICG) using an autoclave at 121–132 °C and 0.21–0.29 MPa. The optimal condition (1.5 × 10⁻⁴ mol L–1 ICG, 132 °C, 10–15 min) yielded the brightest fluorescence. Post-sterilization (PS) enhanced fluorescence by dissolving ICG aggregates and improving fixation. The gauze’s color remained similar to undyed samples, but fluorescence increased by post-sterilization. It emitted strong NIR signals through over 10 mm of tissue and showed minimal dye leakage in artificial body fluid, making it useful for surgical site identification and reducing gauze remnants.
高压灭菌法制备手术用吲哚菁绿染纱布及其近红外荧光特性
一种用吲哚菁绿(ICG)染色的近红外(NIR)荧光纱布,使用高压灭菌器防止纱布残留,并作为手术过程中快速识别目标区域的标志。用不同浓度的ICG水溶液在121 ~ 132℃的高温和0.21 ~ 0.29 MPa的高压下对纱布样品进行染色,增强近红外荧光(FL),提高可染性和牢度。在ICG浓度为1.5 × 10-4 mol / L-1、132℃下染色10-15 min的纱网中,FL最亮,量子产率为3.9%。虽然染色纱布的颜色与未染色纱布的颜色几乎相同,但通过光密度和K/S值估计,在132°C下消毒8 min后,FL强度进一步增加。这种增强归因于ICG团聚体的溶解和棉纤维上的固定增强。此外,高温染色后PS技术有效抑制了纱布在人工体液浸泡过程中ICG的泄漏。从纱布中发射的NIR-FL通过人体组织清晰地观察到,厚度约为10毫米或更多。用吲哚菁绿(ICG)在121 ~ 132℃、0.21 ~ 0.29 MPa的高压灭菌器下对棉花进行染色,制备了近红外荧光手术纱布。最佳条件(1.5 × 10⁻⁴摩尔- 1微克,132°C, 10 - 15分钟)产生最亮的荧光。灭菌后(PS)通过溶解ICG聚集体和改善固定来增强荧光。纱布的颜色与未染色的样品相似,但消毒后荧光增强。它能透过超过10毫米的组织发出强烈的近红外信号,在人工体液中显示出最小的染料泄漏,这有助于识别手术部位和减少纱布残留物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Polymer Journal
Polymer Journal 化学-高分子科学
CiteScore
5.60
自引率
7.10%
发文量
131
审稿时长
2.5 months
期刊介绍: Polymer Journal promotes research from all aspects of polymer science from anywhere in the world and aims to provide an integrated platform for scientific communication that assists the advancement of polymer science and related fields. The journal publishes Original Articles, Notes, Short Communications and Reviews. Subject areas and topics of particular interest within the journal''s scope include, but are not limited to, those listed below: Polymer synthesis and reactions Polymer structures Physical properties of polymers Polymer surface and interfaces Functional polymers Supramolecular polymers Self-assembled materials Biopolymers and bio-related polymer materials Polymer engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书