Md Fazle Rabbi, Helal An Nahiyan, Sourav Karmaker, Fahim Islam Anik
{"title":"Design and preliminary bench-level validation of a low-cost 3D-printed hip-knee exoskeleton for lower-limb rehabilitation training.","authors":"Md Fazle Rabbi, Helal An Nahiyan, Sourav Karmaker, Fahim Islam Anik","doi":"10.1177/20556683261474539","DOIUrl":null,"url":null,"abstract":"<p><p>Lower-limb impairment caused by neurological injury, musculoskeletal disorders, or reduced mobility often requires repetitive rehabilitation exercises, but continuous therapist-assisted therapy may be difficult to access in low-resource settings. In this study, we developed and preliminarily evaluated a low-cost, lightweight, portable hip-knee exoskeleton prototype capable of generating controlled hip and knee joint motion for rehabilitation-oriented range-of-motion training. The prototype was constructed mainly of 3D-printed polylactic acid parts and powered by a pair of high-torque servo motors in the hip and knee joints. A Bluetooth-connected Android app was programmed to offer two modes: rehabilitation mode for independent joint control and a gait-inspired sinusoidal mode that generates coordinated hip and knee joint trajectories. The cost of the materials used to construct the prototype is estimated to be USD 155 with a weight of about 2.1 kg. Joint motion performance was assessed through time-angle measurements at three predefined speed settings. The hip joint (approximately 60° movement) was achieved in 2.2, 1.6, and 1.1 s and the knee joint (approximately 140° movement) was achieved in 3.0, 2.0, and 0.6 s for slow, medium and fast modes, respectively. The trial-to-trial variation in commanded servo position remained below ±1° under the tested conditions. The results demonstrate the feasibility of generating repeatable commanded hip and knee joint motion under controlled laboratory conditions. However, further investigations involving quantitative load-bearing evaluation, safety assessment, user studies, and clinical trials are required before the system can be considered for practical rehabilitation applications.</p>","PeriodicalId":43319,"journal":{"name":"Journal of Rehabilitation and Assistive Technologies Engineering","volume":"13 ","pages":"20556683261474539"},"PeriodicalIF":2.2000,"publicationDate":"2026-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13424928/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation and Assistive Technologies Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20556683261474539","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Lower-limb impairment caused by neurological injury, musculoskeletal disorders, or reduced mobility often requires repetitive rehabilitation exercises, but continuous therapist-assisted therapy may be difficult to access in low-resource settings. In this study, we developed and preliminarily evaluated a low-cost, lightweight, portable hip-knee exoskeleton prototype capable of generating controlled hip and knee joint motion for rehabilitation-oriented range-of-motion training. The prototype was constructed mainly of 3D-printed polylactic acid parts and powered by a pair of high-torque servo motors in the hip and knee joints. A Bluetooth-connected Android app was programmed to offer two modes: rehabilitation mode for independent joint control and a gait-inspired sinusoidal mode that generates coordinated hip and knee joint trajectories. The cost of the materials used to construct the prototype is estimated to be USD 155 with a weight of about 2.1 kg. Joint motion performance was assessed through time-angle measurements at three predefined speed settings. The hip joint (approximately 60° movement) was achieved in 2.2, 1.6, and 1.1 s and the knee joint (approximately 140° movement) was achieved in 3.0, 2.0, and 0.6 s for slow, medium and fast modes, respectively. The trial-to-trial variation in commanded servo position remained below ±1° under the tested conditions. The results demonstrate the feasibility of generating repeatable commanded hip and knee joint motion under controlled laboratory conditions. However, further investigations involving quantitative load-bearing evaluation, safety assessment, user studies, and clinical trials are required before the system can be considered for practical rehabilitation applications.