Ardawan A Youssif, Dindar S Bari, Haval Y Yacoob Aldosky
{"title":"Evaluating the Impact of hydration on electrodermal activity: A Comparison between AC bioimpedance and DC skin potential metrics.","authors":"Ardawan A Youssif, Dindar S Bari, Haval Y Yacoob Aldosky","doi":"10.2478/joeb-2026-0008","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluates the comparative sensitivity and stability of tonic and phasic electrodermal activity (EDA) parameters, specifically skin conductance (SC), susceptance (SS), and potential (SP), following a localized moisturizer intervention. Utilizing a single-group pretest-posttest design (N = 55), the research demonstrates that AC bioimpedance-based metrics (SC and SS) exhibit distinct response dynamics compared to conventional DC-based measures. Tonic-level analysis revealed that SCL and SSL produced nearly identical relative percentage increases (52.6%) compared to SPL (34.46%). While SCL provided the largest absolute change, SSL emerged as the most statistically stable indicator across the cohort, characterized by a highly uniform signal-to-noise ratio (d = 1.23). Phasic analysis revealed that Skin Susceptance Responses (ΔSSRs) demonstrated a highly pronounced downward shift following the intervention, characterized by a -70.2% change from baseline. This negative shift was significantly divergent from the potential response (p < 0.001, d = -0.55), highlighting a distinct directional sensitivity for ΔSSRs under these experimental conditions. These findings suggest that AC-based EDA parameters are highly responsive to the resistive and capacitive shifts within the stratum corneum interface. The results suggest that for applications evaluating localized skin surface changes, a multimodal approach incorporating AC bioimpedance-based metrics may provide a highly responsive framework for detecting acute alterations at the electrode-skin interface compared with traditional potential-based measurements.</p>","PeriodicalId":38125,"journal":{"name":"Journal of Electrical Bioimpedance","volume":"17 1","pages":"52-58"},"PeriodicalIF":0.0000,"publicationDate":"2026-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13428627/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Bioimpedance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/joeb-2026-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
Abstract
This study evaluates the comparative sensitivity and stability of tonic and phasic electrodermal activity (EDA) parameters, specifically skin conductance (SC), susceptance (SS), and potential (SP), following a localized moisturizer intervention. Utilizing a single-group pretest-posttest design (N = 55), the research demonstrates that AC bioimpedance-based metrics (SC and SS) exhibit distinct response dynamics compared to conventional DC-based measures. Tonic-level analysis revealed that SCL and SSL produced nearly identical relative percentage increases (52.6%) compared to SPL (34.46%). While SCL provided the largest absolute change, SSL emerged as the most statistically stable indicator across the cohort, characterized by a highly uniform signal-to-noise ratio (d = 1.23). Phasic analysis revealed that Skin Susceptance Responses (ΔSSRs) demonstrated a highly pronounced downward shift following the intervention, characterized by a -70.2% change from baseline. This negative shift was significantly divergent from the potential response (p < 0.001, d = -0.55), highlighting a distinct directional sensitivity for ΔSSRs under these experimental conditions. These findings suggest that AC-based EDA parameters are highly responsive to the resistive and capacitive shifts within the stratum corneum interface. The results suggest that for applications evaluating localized skin surface changes, a multimodal approach incorporating AC bioimpedance-based metrics may provide a highly responsive framework for detecting acute alterations at the electrode-skin interface compared with traditional potential-based measurements.