{"title":"Assessment of Color Stability and Translucency of Five High-Translucent Resin Composites.","authors":"José Giancarlo Tozo-Burgos, Marco Sánchez-Tito","doi":"10.4317/jced.64173","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate and compare the color stability and translucency of high-translucent resin composites after exposure to distilled water and coffee.</p><p><strong>Materials and methods: </strong>Standardized disc-shaped specimens of five commercially available translucent resin composites (n = 60; 12 specimens per group) were fabricated and evaluated at three time points: baseline (T0), after 30 days in distilled water (T1), and after an additional 30 days in coffee (T2). Color was measured using a spectrophotometer and expressed as E00, while translucency was assessed using the translucency parameter (TP). Data were analyzed using non-parametric tests. The level of significance was set at 5%.</p><p><strong>Results: </strong>All materials showed a significant increase in color change after coffee exposure (p < 0.05). Beautifil II exhibited the highest discoloration at T2-T0 (17.76 [2.18]), followed by Forma Trans (14.93 [3.70]), whereas Opallis T Neutral showed the lowest values (8.31 [2.84]). At T1-T0, Opallis T Neutral also presented the lowest color change (1.42 [0.67]). Regarding translucency, Filtek Z350 XT Trans showed the highest TP values at T2 (15.38 [2.74]), while several materials, particularly Beautifil II (-4.08 [4.35]) and PALFIQUE LX5 (-4.60 [2.96]), exhibited reductions in TP after coffee immersion. Opallis T Neutral showed minimal variation in translucency (-0.19 [1.19]).</p><p><strong>Conclusions: </strong>High-translucent resin composites showed significant differences in optical stability. Coffee exposure increased discoloration and reduced translucency in most materials. Opallis T Neutral demonstrated the best overall performance.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"18 8","pages":"e974-e981"},"PeriodicalIF":0.0000,"publicationDate":"2026-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13428311/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.64173","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Background: To evaluate and compare the color stability and translucency of high-translucent resin composites after exposure to distilled water and coffee.
Materials and methods: Standardized disc-shaped specimens of five commercially available translucent resin composites (n = 60; 12 specimens per group) were fabricated and evaluated at three time points: baseline (T0), after 30 days in distilled water (T1), and after an additional 30 days in coffee (T2). Color was measured using a spectrophotometer and expressed as E00, while translucency was assessed using the translucency parameter (TP). Data were analyzed using non-parametric tests. The level of significance was set at 5%.
Results: All materials showed a significant increase in color change after coffee exposure (p < 0.05). Beautifil II exhibited the highest discoloration at T2-T0 (17.76 [2.18]), followed by Forma Trans (14.93 [3.70]), whereas Opallis T Neutral showed the lowest values (8.31 [2.84]). At T1-T0, Opallis T Neutral also presented the lowest color change (1.42 [0.67]). Regarding translucency, Filtek Z350 XT Trans showed the highest TP values at T2 (15.38 [2.74]), while several materials, particularly Beautifil II (-4.08 [4.35]) and PALFIQUE LX5 (-4.60 [2.96]), exhibited reductions in TP after coffee immersion. Opallis T Neutral showed minimal variation in translucency (-0.19 [1.19]).
Conclusions: High-translucent resin composites showed significant differences in optical stability. Coffee exposure increased discoloration and reduced translucency in most materials. Opallis T Neutral demonstrated the best overall performance.
背景:评价和比较高半透明树脂复合材料在蒸馏水和咖啡作用后的颜色稳定性和半透明性。材料和方法:制作五种市售半透明树脂复合材料的标准化圆盘状标本(n = 60,每组12个标本),并在三个时间点进行评估:基线(T0),蒸馏水30天后(T1),咖啡30天后(T2)。用分光光度计测量颜色并表示为E00,而用半透明参数(TP)评估半透明性。数据分析采用非参数检验。显著性水平设为5%。结果:咖啡暴露后,所有材料的颜色变化均显著增加(p < 0.05)。在T2-T0变色程度最高的是Beautifil II(17.76[2.18]),其次是Forma Trans(14.93[3.70]),最低的是Opallis T Neutral(8.31[2.84])。在T1-T0时,Opallis T Neutral的颜色变化也最低(1.42[0.67])。在透光性方面,Filtek Z350 XT Trans在T2时TP值最高(15.38[2.74]),而一些材料,特别是Beautifil II(-4.08[4.35])和PALFIQUE LX5(-4.60[2.96]),在咖啡浸泡后TP值降低。Opallis T Neutral的透明度变化最小(-0.19[1.19])。结论:高半透明树脂复合材料的光学稳定性有显著差异。咖啡会增加大多数材料的变色并降低其透明度。Opallis T Neutral表现出最佳的综合性能。
期刊介绍:
Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery