In vitro evaluation of the microhardness of conventional and bulk-fill resins based on the depth of light-curing and the curing unit.

Q2 Dentistry
Journal of Clinical and Experimental Dentistry Pub Date : 2026-07-29 eCollection Date: 2026-07-01 DOI:10.4317/jced.64256
Vanessa Verónica Sara García-Mendoza, Rosa Josefina Roncal-Espinoza
{"title":"In vitro evaluation of the microhardness of conventional and bulk-fill resins based on the depth of light-curing and the curing unit.","authors":"Vanessa Verónica Sara García-Mendoza, Rosa Josefina Roncal-Espinoza","doi":"10.4317/jced.64256","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To evaluate the microhardness of conventional and bulk-fill composite resins based on the depth of light-curing (2 mm and 4 mm) and the curing unit used (VALO Grand and BluePhase N G4 lamp).</p><p><strong>Material and methods: </strong>Discs were fabricated using two bulk-fill resins: Beautifil Bulk (BB) and Filtek Bulk Fill (ZB); and two conventional resins: Beautiful II (BC) and Filtek Z350 XT (ZC). For the preparation, the light-curing depth was set at 2 and 4 mm, and the curing units used were VALO Grand and BluePhase N G4. Microhardness was measured using the Vickers test on light-cured samples under standardized conditions. Statistical analysis was performed using ANOVA and the Tukey test (p < 0.05).</p><p><strong>Results: </strong>Significant differences were found between the groups, with the BB 4mm Valo group exhibiting the lowest microhardness values and significant differences compared to the others. Meanwhile, the 4 mm Bluephase ZC resin exhibited the highest microhardness values compared to the bulk-fill resin. At a thickness of 2 mm, the conventional resins showed similar values regardless of the polymerization source, except for BB, which performed better with the Valo unit. In addition, Valo demonstrated good performance with ZC at both thicknesses and results comparable to Beautifil II at 2 mm. Bluephase showed consistent values across all groups and depths, with superior performance when applied over ZC.</p><p><strong>Conclusions: </strong>The results showed that the final microhardness of the restorative material is influenced by a combination of resin type, depth, and light-curing unit; the conventional composite resin that exhibited the highest microhardness values was ZC, light-cured using a Bluephase light source at a thickness of 4 mm, compared to the bulk-fill resin.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"18 8","pages":"e1015-e1020"},"PeriodicalIF":0.0000,"publicationDate":"2026-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13428315/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.64256","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To evaluate the microhardness of conventional and bulk-fill composite resins based on the depth of light-curing (2 mm and 4 mm) and the curing unit used (VALO Grand and BluePhase N G4 lamp).

Material and methods: Discs were fabricated using two bulk-fill resins: Beautifil Bulk (BB) and Filtek Bulk Fill (ZB); and two conventional resins: Beautiful II (BC) and Filtek Z350 XT (ZC). For the preparation, the light-curing depth was set at 2 and 4 mm, and the curing units used were VALO Grand and BluePhase N G4. Microhardness was measured using the Vickers test on light-cured samples under standardized conditions. Statistical analysis was performed using ANOVA and the Tukey test (p < 0.05).

Results: Significant differences were found between the groups, with the BB 4mm Valo group exhibiting the lowest microhardness values and significant differences compared to the others. Meanwhile, the 4 mm Bluephase ZC resin exhibited the highest microhardness values compared to the bulk-fill resin. At a thickness of 2 mm, the conventional resins showed similar values regardless of the polymerization source, except for BB, which performed better with the Valo unit. In addition, Valo demonstrated good performance with ZC at both thicknesses and results comparable to Beautifil II at 2 mm. Bluephase showed consistent values across all groups and depths, with superior performance when applied over ZC.

Conclusions: The results showed that the final microhardness of the restorative material is influenced by a combination of resin type, depth, and light-curing unit; the conventional composite resin that exhibited the highest microhardness values was ZC, light-cured using a Bluephase light source at a thickness of 4 mm, compared to the bulk-fill resin.

基于光固化深度和固化单元的常规树脂和填充树脂显微硬度体外评价。
背景:基于光固化深度(2mm和4mm)和固化单元(VALO Grand和BluePhase N G4灯)来评价常规和填充型复合树脂的显微硬度。材料和方法:使用两种散装填充树脂:Beautifil散装(BB)和Filtek散装填充(ZB)制造光盘;以及两种传统树脂:Beautiful II (BC)和Filtek Z350 XT (ZC)。制备时,光固化深度分别为2和4 mm,固化单元为VALO Grand和BluePhase N G4。在标准化条件下,用维氏试验测量光固化样品的显微硬度。统计学分析采用方差分析和Tukey检验(p < 0.05)。结果:组间存在显著性差异,BB 4mm Valo组的显微硬度值最低,与其他组相比差异显著。同时,4 mm Bluephase ZC树脂的显微硬度值最高。在厚度为2mm时,无论聚合源是什么,常规树脂都显示出相似的值,除了BB,它在Valo装置上表现更好。此外,Valo在两种厚度下都表现出良好的ZC性能,其结果与2毫米的Beautifil II相当。Bluephase在所有组和深度上显示一致的值,在ZC上应用时具有优越的性能。结论:树脂类型、深度、光固化单元等因素共同影响修复材料的最终显微硬度;常规复合树脂的显微硬度值最高的是ZC,使用蓝相光源光固化,厚度为4 mm,与填充树脂相比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书