{"title":"Subregion-based maximum similarity search registration method for transverse chromatic aberration correction in ultra-widefield scanning laser ophthalmoscopy images.","authors":"Lin Ji, Yunshuai Mi, Dewen Xu, Shuo Wang, ShuaiWei Mu, Yun Xiao, HaoMin Yang, Wei Huang, Yunhai Zhang, Wei Xia","doi":"10.1117/1.JBO.31.8.086001","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Ultra-widefield scanning laser ophthalmoscopy (UWF SLO), a confocal scanning-based ophthalmic imaging modality widely used in clinical and research ophthalmology, offers an ultra-wide field of view, high resolution, and real-time dynamic imaging. However, multiwavelength imaging-induced transverse chromatic aberration (TCA) is markedly exacerbated in the peripheral retina, causing ghosting artifacts of retinal vessels and other critical anatomical structures. This severely limits image quality and the reliability of downstream quantitative analysis.</p><p><strong>Aim: </strong>We aim to correct TCA in multiwavelength UWF SLO images using a subregion-based maximum similarity search registration method, thereby eliminating vascular ghosting artifacts to enhance image quality for reliable clinical analysis.</p><p><strong>Approach: </strong>In this study, we address the nonuniform TCA between the red and green channels in multiwavelength UWF SLO imaging through three core steps: grid-based subregion sampling, high-precision control point extraction via local optimal matching guided by zero-mean normalized cross-correlation (ZNCC), and global perspective transformation model fitting. The effectiveness of the proposed method was validated on fundus image samples acquired by our in-house-developed UWF SLO system, through both qualitative visual assessment and quantitative evaluation metrics.</p><p><strong>Results: </strong>The proposed correction method significantly mitigated TCA in UWF SLO images and greatly improved the spatial alignment of retinal vascular contours between the red and green channels. Validation on 11 fundus images showed a significant enhancement in vascular matching performance: the mean dice similarity coefficient increased by 26.7% relatively (from <math><mrow><mn>0.595</mn> <mo>±</mo> <mn>0.060</mn></mrow> </math> to <math><mrow><mn>0.754</mn> <mo>±</mo> <mn>0.035</mn></mrow> </math> ) and the mean intersection over union increased by 42.5% relatively (from <math><mrow><mn>0.426</mn> <mo>±</mo> <mn>0.061</mn></mrow> </math> to <math><mrow><mn>0.607</mn> <mo>±</mo> <mn>0.044</mn></mrow> </math> ). Paired samples t-test verified highly statistically significant improvements in both metrics (all <math><mrow><mi>p</mi> <mo><</mo> <mn>0.001</mn></mrow> </math> ).</p><p><strong>Conclusions: </strong>The proposed subregion-based maximum similarity search registration method effectively corrects TCA in multiwavelength UWF SLO fundus images, significantly improves image quality, and provides reliable technical support for clinical ophthalmic practice and downstream quantitative fundus image analysis.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"31 8","pages":"086001"},"PeriodicalIF":3.3000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13428614/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.31.8.086001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Ultra-widefield scanning laser ophthalmoscopy (UWF SLO), a confocal scanning-based ophthalmic imaging modality widely used in clinical and research ophthalmology, offers an ultra-wide field of view, high resolution, and real-time dynamic imaging. However, multiwavelength imaging-induced transverse chromatic aberration (TCA) is markedly exacerbated in the peripheral retina, causing ghosting artifacts of retinal vessels and other critical anatomical structures. This severely limits image quality and the reliability of downstream quantitative analysis.

Aim: We aim to correct TCA in multiwavelength UWF SLO images using a subregion-based maximum similarity search registration method, thereby eliminating vascular ghosting artifacts to enhance image quality for reliable clinical analysis.

Approach: In this study, we address the nonuniform TCA between the red and green channels in multiwavelength UWF SLO imaging through three core steps: grid-based subregion sampling, high-precision control point extraction via local optimal matching guided by zero-mean normalized cross-correlation (ZNCC), and global perspective transformation model fitting. The effectiveness of the proposed method was validated on fundus image samples acquired by our in-house-developed UWF SLO system, through both qualitative visual assessment and quantitative evaluation metrics.

Results: The proposed correction method significantly mitigated TCA in UWF SLO images and greatly improved the spatial alignment of retinal vascular contours between the red and green channels. Validation on 11 fundus images showed a significant enhancement in vascular matching performance: the mean dice similarity coefficient increased by 26.7% relatively (from 0.595 ± 0.060 to 0.754 ± 0.035 ) and the mean intersection over union increased by 42.5% relatively (from 0.426 ± 0.061 to 0.607 ± 0.044 ). Paired samples t-test verified highly statistically significant improvements in both metrics (all p < 0.001 ).

Conclusions: The proposed subregion-based maximum similarity search registration method effectively corrects TCA in multiwavelength UWF SLO fundus images, significantly improves image quality, and provides reliable technical support for clinical ophthalmic practice and downstream quantitative fundus image analysis.

基于子区域的最大相似度搜索配准方法用于超宽视场扫描激光检眼镜图像横向色差校正。
意义:超宽视场扫描激光眼镜(UWF SLO)是一种基于共聚焦扫描的眼科成像方式,具有超宽视场、高分辨率、实时动态成像等特点,广泛应用于眼科临床和研究。然而,多波长成像引起的横向色差(TCA)在视网膜周围明显加剧,导致视网膜血管和其他关键解剖结构的重影伪影。这严重限制了图像质量和下游定量分析的可靠性。目的:采用基于子区域的最大相似度搜索配准方法校正多波长UWF SLO图像中的TCA,从而消除血管重影伪影,提高图像质量,为可靠的临床分析提供依据。方法:本研究通过基于网格的子区域采样、基于零均值归一化互相关(ZNCC)的局部最优匹配的高精度控制点提取和全局视角变换模型拟合三个核心步骤来解决多波长UWF SLO成像中红绿通道之间的非均匀TCA问题。通过定性视觉评价和定量评价指标,在自主开发的UWF SLO系统采集的眼底图像样本上验证了该方法的有效性。结果:所提出的校正方法显著减轻了UWF SLO图像中的TCA,并大大改善了视网膜血管轮廓在红绿通道之间的空间对齐。对11张眼底图像进行验证,血管匹配性能显著增强,骰子相似系数均值相对提高26.7%(从0.595±0.060提高到0.754±0.035),相交/结合均值相对提高42.5%(从0.426±0.061提高到0.607±0.044)。配对样本t检验证实了这两个指标在统计学上的显著改善(p均为0.001)。结论:提出的基于子区域的最大相似度搜索配准方法可有效校正多波长UWF SLO眼底图像中的TCA,显著提高图像质量,为临床眼科实践及下游眼底图像定量分析提供可靠的技术支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书