Effect of albuterol on compliance and distensibility of the trachea and lungs.

IF 3.7 3区 医学 Q1 PHYSIOLOGY
Journal of applied physiology Pub Date : 2026-09-01 Epub Date: 2026-08-01 DOI:10.1152/japplphysiol.00064.2026
Chamindu C Gunatilaka, Qiwei Xiao, Keith McConnell, Mark Sketch, Carolyn Doerning, Jasmine Hales, Angie Cummins, Ross Schierling, Ajay Kaul, Jason C Woods, Alister J Bates, Erik B Hysinger
{"title":"Effect of albuterol on compliance and distensibility of the trachea and lungs.","authors":"Chamindu C Gunatilaka, Qiwei Xiao, Keith McConnell, Mark Sketch, Carolyn Doerning, Jasmine Hales, Angie Cummins, Ross Schierling, Ajay Kaul, Jason C Woods, Alister J Bates, Erik B Hysinger","doi":"10.1152/japplphysiol.00064.2026","DOIUrl":null,"url":null,"abstract":"<p><p>Tracheomalacia (TM), the most common abnormality of the pediatric trachea, results in dynamic expiratory airway collapse due to weakened cartilage and reduced smooth muscle tone. Although bronchodilators such as albuterol are widely used in children with wheezing, their impact on TM remains unclear because prior studies have not simultaneously evaluated tracheal and lung mechanics in vivo. This study aimed to separately quantify the effects of albuterol on both tracheal distensibility and compliance, as well as lung compliance, using a controlled porcine model. Ten spontaneously breathing swine underwent high-resolution computed tomography (CT) imaging at multiple controlled tracheal lumen pressures (P<sub>LUM</sub>) ranging from +10 to -10 cmH<sub>2</sub>O, both before and after administration of 5 mg nebulized albuterol. Tracheal and pleural pressures were simultaneously recorded. Three-dimensional airways and lungs were segmented from CT images to calculate cross-sectional areas and volumes. Tracheal distensibility and compliance, as well as lung compliance, were determined by the slope of area or volume versus transmural pressure. Albuterol significantly increased tracheal distensibility (4.30 ± 1.0 to 4.78 ± 1.3 mm<sup>2</sup>/mmHg, <i>P</i> = 0.010) and tracheal compliance (327 ± 102 to 367 ± 117 mm³/mmHg, <i>P</i> = 0.018). Lung compliance also increased significantly in 9 evaluable swine [(2.9 ± 1) × 10<sup>4</sup> to (3.8 ± 1.1) × 10<sup>4</sup> mm³/mmHg, <i>P</i> = 0.010]. Albuterol increases both tracheal and lung compliance, supporting clinical concerns that bronchodilators may exacerbate airway collapse in TM. These findings demonstrate the complex and competing mechanical effects of bronchodilators in TM and stress the importance of accounting for both tracheal and lung responses in managing dynamic airway collapse.<b>NEW & NOTEWORTHY</b> This study introduces an in vivo swine model to simultaneously assess how albuterol alters tracheal and lung compliance. Albuterol increased compliance in both regions, potentially exacerbating airway collapse in tracheomalacia. These findings clarify the paradoxical effects of bronchodilators and emphasize the importance of individualized respiratory management for pediatric patients with airway abnormalities often mistaken for asthma.</p>","PeriodicalId":15160,"journal":{"name":"Journal of applied physiology","volume":" ","pages":"795-801"},"PeriodicalIF":3.7000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/japplphysiol.00064.2026","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/8/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Tracheomalacia (TM), the most common abnormality of the pediatric trachea, results in dynamic expiratory airway collapse due to weakened cartilage and reduced smooth muscle tone. Although bronchodilators such as albuterol are widely used in children with wheezing, their impact on TM remains unclear because prior studies have not simultaneously evaluated tracheal and lung mechanics in vivo. This study aimed to separately quantify the effects of albuterol on both tracheal distensibility and compliance, as well as lung compliance, using a controlled porcine model. Ten spontaneously breathing swine underwent high-resolution computed tomography (CT) imaging at multiple controlled tracheal lumen pressures (PLUM) ranging from +10 to -10 cmH2O, both before and after administration of 5 mg nebulized albuterol. Tracheal and pleural pressures were simultaneously recorded. Three-dimensional airways and lungs were segmented from CT images to calculate cross-sectional areas and volumes. Tracheal distensibility and compliance, as well as lung compliance, were determined by the slope of area or volume versus transmural pressure. Albuterol significantly increased tracheal distensibility (4.30 ± 1.0 to 4.78 ± 1.3 mm2/mmHg, P = 0.010) and tracheal compliance (327 ± 102 to 367 ± 117 mm³/mmHg, P = 0.018). Lung compliance also increased significantly in 9 evaluable swine [(2.9 ± 1) × 104 to (3.8 ± 1.1) × 104 mm³/mmHg, P = 0.010]. Albuterol increases both tracheal and lung compliance, supporting clinical concerns that bronchodilators may exacerbate airway collapse in TM. These findings demonstrate the complex and competing mechanical effects of bronchodilators in TM and stress the importance of accounting for both tracheal and lung responses in managing dynamic airway collapse.NEW & NOTEWORTHY This study introduces an in vivo swine model to simultaneously assess how albuterol alters tracheal and lung compliance. Albuterol increased compliance in both regions, potentially exacerbating airway collapse in tracheomalacia. These findings clarify the paradoxical effects of bronchodilators and emphasize the importance of individualized respiratory management for pediatric patients with airway abnormalities often mistaken for asthma.

沙丁胺醇对气管和肺顺应性和扩张性的影响。
气管软化症(TM)是儿童气管最常见的异常,由于软骨减弱和平滑肌张力降低导致动态呼气气道塌陷。尽管沙丁胺醇等支气管扩张剂广泛用于儿童喘息,但其对TM的影响尚不清楚,因为先前的研究并未同时评估体内气管和肺力学。本研究旨在分别量化沙丁胺醇对气管扩张性和顺应性以及肺顺应性的影响,使用受控猪模型。10只自主呼吸的猪在给予5mg雾化沙丁胺醇之前和之后,在+10到-10 cmH / O的多重控制气管腔压(PLUM)下进行了高分辨率计算机断层扫描(CT)成像。同时记录气管和胸膜压力。从CT图像中分割三维气道和肺,计算横截面积和体积。气管扩张性和顺应性,以及肺顺应性,由面积或体积与跨壁压力的斜率决定。沙丁胺醇显著增加气管扩张(4.30 ± 1.0 ~ 4.78 ± 1.3 mm²/mmHg, p=0.010)和气管顺应性(327 ± 102 ~ 367 ± 117 mm³/mmHg, p=0.018)。9头可评估猪的肺顺应性也显著增加((2.9 ± 1)×10⁴至(3.8 ± 1.1)×10⁴mm³/mmHg, p=0.010)。沙丁胺醇增加了气管和肺的顺应性,支持了临床对支气管扩张剂可能加剧TM气道塌陷的担忧。这些发现证明了支气管扩张剂在TM中的复杂和相互竞争的机械作用,并强调了在处理动态气道塌陷时兼顾气管和肺反应的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.00
自引率
9.10%
发文量
296
审稿时长
2-4 weeks
期刊介绍: The Journal of Applied Physiology publishes the highest quality original research and reviews that examine novel adaptive and integrative physiological mechanisms in humans and animals that advance the field. The journal encourages the submission of manuscripts that examine the acute and adaptive responses of various organs, tissues, cells and/or molecular pathways to environmental, physiological and/or pathophysiological stressors. As an applied physiology journal, topics of interest are not limited to a particular organ system. The journal, therefore, considers a wide array of integrative and translational research topics examining the mechanisms involved in disease processes and mitigation strategies, as well as the promotion of health and well-being throughout the lifespan. Priority is given to manuscripts that provide mechanistic insight deemed to exert an impact on the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书