Effect of Rinsing Water Temperature on Microleakage of Dental Composite Restorations: An In-Vitro Study.

Q3 Dentistry
Frontiers in Dentistry Pub Date : 2026-02-01 eCollection Date: 2026-01-01 DOI:10.18502/fid.v23i6.21235
Farzaneh Shirani, Niloufar Jafari, Zahra Alipouriani, Maryam Adhami
{"title":"Effect of Rinsing Water Temperature on Microleakage of Dental Composite Restorations: An In-Vitro Study.","authors":"Farzaneh Shirani, Niloufar Jafari, Zahra Alipouriani, Maryam Adhami","doi":"10.18502/fid.v23i6.21235","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives:</b> This study assessed the impact of rinsing water temperature on microleakage of dental composite restorations. <b>Materials and Methods:</b> This in vitro study was conducted on 72 extracted premolars. Buccal and lingual Class V cavities were prepared with gingival margins 1mm beneath the cementoenamel junction (CEJ) and occlusal margins 2mm above the CEJ. The specimens were classified into three groups (n=24) for rinsing with water at 23°C, 4°C, and 45°C before the bonding procedure. Lingual cavities were bonded with a self-etch adhesive, and buccal cavities were bonded with a total-etch adhesive. After composite restoration, the specimens underwent 1000 thermal cycles between 5-55°C. They were then divided into two groups for storage for either 24 hours or 2 months. Optical and electron microscopic assessments were performed to score microleakage at the occlusal and gingival margins of the specimens. The Kruskal-Wallis, Mann-Whitney, and Wilcoxon tests were run to analyze the data (alpha=0.05). <b>Results:</b> Regardless of the bonding system and storage time, microleakage was significantly higher in the 4°C rinsing water group (P<0.05). Gingival margins bonded with the total-etch adhesive had a significantly higher microleakage than the occlusal margins in both 23°C and 45°C groups (P<0.05), but the self-etch adhesive showed no significant difference (P>0.05). <b>Conclusion:</b> According to the results of this in vitro study, rinsing the cavity with warm water (23°C and 45°C) appears to be an effective method to reduce the rate of microleakage.</p>","PeriodicalId":12445,"journal":{"name":"Frontiers in Dentistry","volume":"23 ","pages":"6"},"PeriodicalIF":0.0000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13428505/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/fid.v23i6.21235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This study assessed the impact of rinsing water temperature on microleakage of dental composite restorations. Materials and Methods: This in vitro study was conducted on 72 extracted premolars. Buccal and lingual Class V cavities were prepared with gingival margins 1mm beneath the cementoenamel junction (CEJ) and occlusal margins 2mm above the CEJ. The specimens were classified into three groups (n=24) for rinsing with water at 23°C, 4°C, and 45°C before the bonding procedure. Lingual cavities were bonded with a self-etch adhesive, and buccal cavities were bonded with a total-etch adhesive. After composite restoration, the specimens underwent 1000 thermal cycles between 5-55°C. They were then divided into two groups for storage for either 24 hours or 2 months. Optical and electron microscopic assessments were performed to score microleakage at the occlusal and gingival margins of the specimens. The Kruskal-Wallis, Mann-Whitney, and Wilcoxon tests were run to analyze the data (alpha=0.05). Results: Regardless of the bonding system and storage time, microleakage was significantly higher in the 4°C rinsing water group (P<0.05). Gingival margins bonded with the total-etch adhesive had a significantly higher microleakage than the occlusal margins in both 23°C and 45°C groups (P<0.05), but the self-etch adhesive showed no significant difference (P>0.05). Conclusion: According to the results of this in vitro study, rinsing the cavity with warm water (23°C and 45°C) appears to be an effective method to reduce the rate of microleakage.

冲洗水温对牙体复合修复体微渗漏影响的体外研究
目的:研究冲洗水温对复合材料修复体微渗漏的影响。材料与方法:对72颗拔除的前磨牙进行体外实验。在牙髓-牙釉质接合处(CEJ)下方1mm的牙龈边缘和CEJ上方2mm的咬合边缘上制备颊部和舌部的V类腔。将样品分为三组(n=24),分别在23°C、4°C和45°C用水冲洗,然后进行粘合操作。舌腔用自蚀刻胶粘接,颊腔用全蚀刻胶粘接。复合修复后,试件经历了1000次5 ~ 55℃的热循环。然后将它们分成两组,分别保存24小时和2个月。进行光学和电子显微镜评估,对标本的咬合和牙龈边缘的微渗漏进行评分。采用Kruskal-Wallis、Mann-Whitney和Wilcoxon检验对数据进行分析(alpha=0.05)。结果:无论粘接系统和保存时间如何,4°C冲洗水组的微渗漏率均显著高于对照组(P0.05)。结论:根据体外实验结果,用温水(23°C和45°C)冲洗腔体是降低微渗漏率的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Frontiers in Dentistry
Frontiers in Dentistry Dentistry-General Dentistry
CiteScore
1.00
自引率
0.00%
发文量
34
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书