Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study.
IF 1.6 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Wellington Gianoti Lustre, Libnah Leal, Vinicius Cardoso, Mateus Aves Borges Cristino, Carolina Dutra Queiroz Flumignan, Ronald Luiz Gomes Flumignan, Jorge Eduardo de Amorim, Luis Carlos Uta Nakano
{"title":"Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study.","authors":"Wellington Gianoti Lustre, Libnah Leal, Vinicius Cardoso, Mateus Aves Borges Cristino, Carolina Dutra Queiroz Flumignan, Ronald Luiz Gomes Flumignan, Jorge Eduardo de Amorim, Luis Carlos Uta Nakano","doi":"10.1007/s40477-026-01182-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Lifelong imaging surveillance after endovascular aneurysm repair (EVAR) is essential for endoleak detection but is limited by cumulative radiation and nephrotoxicity from computed tomography angiography (CTA). Contrast-enhanced ultrasound (CEUS) has emerged as a promising alternative, although prospective comparative data remain limited.</p><p><strong>Methods: </strong>In this prospective, single-centre diagnostic accuracy study, 30 consecutive patients (mean age 78.5 ± 7.1 years; 70% male) undergoing EVAR follow-up were evaluated with duplex ultrasound (DUS), CEUS (SonoVue®), and CTA within a 30-day interval. CTA served as the reference standard. Diagnostic performance metrics were calculated with 95% confidence intervals (CIs) according to STARD recommendations.</p><p><strong>Results: </strong>Endoleaks were identified in 11 patients (36.7%). CTA detected 8 cases (26.7%), CEUS 9 (30.0%), and DUS 4 (13.3%). CEUS demonstrated high sensitivity (87.5%; 95% CI 47.3-99.7%) and specificity (90.9%; 70.8-98.9%), with overall accuracy of 90.0% (73.5-97.9%). In contrast, DUS showed limited sensitivity (33.3%; 9.9-65.1%) despite perfect specificity (100%), yielding lower accuracy (73.3%). Inter-modality agreement was 83.3%.</p><p><strong>Conclusions: </strong>CEUS demonstrates high diagnostic accuracy for endoleak detection after EVAR and represents a robust, radiation-free alternative to CTA for longitudinal surveillance. Given its favourable safety profile and diagnostic performance, CEUS should be considered a first-line imaging modality in routine follow-up, with CTA reserved for equivocal findings or pre-interventional planning. These results support a paradigm shift toward CEUS-based surveillance strategies.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":" ","pages":"639-646"},"PeriodicalIF":1.6000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13588977/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-026-01182-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Lifelong imaging surveillance after endovascular aneurysm repair (EVAR) is essential for endoleak detection but is limited by cumulative radiation and nephrotoxicity from computed tomography angiography (CTA). Contrast-enhanced ultrasound (CEUS) has emerged as a promising alternative, although prospective comparative data remain limited.
Methods: In this prospective, single-centre diagnostic accuracy study, 30 consecutive patients (mean age 78.5 ± 7.1 years; 70% male) undergoing EVAR follow-up were evaluated with duplex ultrasound (DUS), CEUS (SonoVue®), and CTA within a 30-day interval. CTA served as the reference standard. Diagnostic performance metrics were calculated with 95% confidence intervals (CIs) according to STARD recommendations.
Results: Endoleaks were identified in 11 patients (36.7%). CTA detected 8 cases (26.7%), CEUS 9 (30.0%), and DUS 4 (13.3%). CEUS demonstrated high sensitivity (87.5%; 95% CI 47.3-99.7%) and specificity (90.9%; 70.8-98.9%), with overall accuracy of 90.0% (73.5-97.9%). In contrast, DUS showed limited sensitivity (33.3%; 9.9-65.1%) despite perfect specificity (100%), yielding lower accuracy (73.3%). Inter-modality agreement was 83.3%.
Conclusions: CEUS demonstrates high diagnostic accuracy for endoleak detection after EVAR and represents a robust, radiation-free alternative to CTA for longitudinal surveillance. Given its favourable safety profile and diagnostic performance, CEUS should be considered a first-line imaging modality in routine follow-up, with CTA reserved for equivocal findings or pre-interventional planning. These results support a paradigm shift toward CEUS-based surveillance strategies.
背景:血管内动脉瘤修复(EVAR)后的终身影像学监测是检测血管内漏的必要条件,但受到计算机断层血管造影(CTA)的累积辐射和肾毒性的限制。对比增强超声(CEUS)已成为一种有希望的替代方法,尽管前瞻性比较数据仍然有限。方法:在这项前瞻性、单中心诊断准确性研究中,30例连续接受EVAR随访的患者(平均年龄78.5±7.1岁,70%为男性)在30天内通过双工超声(DUS)、超声造影(SonoVue®)和CTA进行评估。CTA作为参考标准。根据STARD建议,以95%置信区间(ci)计算诊断性能指标。结果:11例患者(36.7%)出现内漏。CTA检出8例(26.7%),CEUS 9例(30.0%),DUS 4例(13.3%)。超声造影具有较高的灵敏度(87.5%;95% CI 47.3-99.7%)和特异性(90.9%;70.8-98.9%),总体准确率为90.0%(73.5-97.9%)。相比之下,DUS尽管具有完美的特异性(100%),但灵敏度有限(33.3%;9.9-65.1%),准确性较低(73.3%)。多式联运协议占83.3%。结论:超声造影对EVAR后的内漏检测具有较高的诊断准确性,是一种可靠的、无辐射的纵向监测替代CTA的方法。鉴于其良好的安全性和诊断性能,超声造影应被视为常规随访的一线成像方式,CTA保留用于模棱两可的发现或介入前计划。这些结果支持向以ceus为基础的监测战略的范式转变。
期刊介绍:
The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.