Clinical Evaluation of Two-Stage Revision Total Knee Arthroplasty Using Silicone Mold-Based and Metal Mold-Based Antibiotic-Loaded Knee Spacers: A Comparative Study.
{"title":"Clinical Evaluation of Two-Stage Revision Total Knee Arthroplasty Using Silicone Mold-Based and Metal Mold-Based Antibiotic-Loaded Knee Spacers: A Comparative Study.","authors":"Mohamad Amin Younessi Heravi, Reza Ganji, Ismaeil Garivani, Negin Armide","doi":"10.47176/mjiri.40.51","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The gold standard for managing infection following total knee arthroplasty (TKA) is two-stage revision surgery, which entails the placement of a spacer in the knee during the initial stage. This study aimed to compare metal mold-based and silicone mold-based spacers regarding clinical evaluation and infection control in patients with infected TKAs.</p><p><strong>Methods: </strong>In this study, we assigned fourteen individuals with infected knees following arthroplasty to either the metal mold-based spacer group (control) or the silicon mold-based spacer group. The WOMAC Score, Knee Society Score (KSS), and range of motion (ROM) were utilized for clinical evaluation prior to spacer implantation and during the post-first stage of surgery follow-up. Gain score analysis (post-pre difference) was conducted to assess functional improvement over time. The Wilcoxon signed-rank test and the Mann-Whitney U test were applied for statistical analysis using SPSS software.</p><p><strong>Results: </strong>Knee infection was eliminated in all participants across both groups. Post-surgery, ROM improved from 59.28 ± 20.29° to 99.00 ± 5.65° in the control group, while the intervention group demonstrated an increase in ROM from 66.42 ± 24.78° to 101.42 ± 8.01°. Additionally, the KSS improved from 38.28 ± 23.78 to 123.71 ± 20.53 in the control group and from 35.71 ± 30.99 to 124.85 ± 27.49 in the intervention group. The WOMAC score increased from 48.71 ± 9.23 to 70.57 ± 5.28 in the control group and from 47.71 ± 12.03 to 72.57 ± 6.32 in the intervention group. There were no statistically significant differences between the two groups in terms of ROM (<i>P</i> = 0.751), WOMAC (<i>P</i> = 0.678), or KSS (<i>P</i> = 0.806) in the gain scores analysis.</p><p><strong>Conclusion: </strong>Metal mold-based spacers and silicone mold-based spacers demonstrate no significant differences in functional assessment (ROM, KSS, and WOMAC) or infection control. These findings indicate that silicone mold-based spacers may serve as a reliable alternative to conventional metal mold-based spacers, particularly in low-income countries.</p>","PeriodicalId":18361,"journal":{"name":"Medical Journal of the Islamic Republic of Iran","volume":"40 ","pages":"51"},"PeriodicalIF":0.0000,"publicationDate":"2026-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13403875/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of the Islamic Republic of Iran","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47176/mjiri.40.51","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The gold standard for managing infection following total knee arthroplasty (TKA) is two-stage revision surgery, which entails the placement of a spacer in the knee during the initial stage. This study aimed to compare metal mold-based and silicone mold-based spacers regarding clinical evaluation and infection control in patients with infected TKAs.
Methods: In this study, we assigned fourteen individuals with infected knees following arthroplasty to either the metal mold-based spacer group (control) or the silicon mold-based spacer group. The WOMAC Score, Knee Society Score (KSS), and range of motion (ROM) were utilized for clinical evaluation prior to spacer implantation and during the post-first stage of surgery follow-up. Gain score analysis (post-pre difference) was conducted to assess functional improvement over time. The Wilcoxon signed-rank test and the Mann-Whitney U test were applied for statistical analysis using SPSS software.
Results: Knee infection was eliminated in all participants across both groups. Post-surgery, ROM improved from 59.28 ± 20.29° to 99.00 ± 5.65° in the control group, while the intervention group demonstrated an increase in ROM from 66.42 ± 24.78° to 101.42 ± 8.01°. Additionally, the KSS improved from 38.28 ± 23.78 to 123.71 ± 20.53 in the control group and from 35.71 ± 30.99 to 124.85 ± 27.49 in the intervention group. The WOMAC score increased from 48.71 ± 9.23 to 70.57 ± 5.28 in the control group and from 47.71 ± 12.03 to 72.57 ± 6.32 in the intervention group. There were no statistically significant differences between the two groups in terms of ROM (P = 0.751), WOMAC (P = 0.678), or KSS (P = 0.806) in the gain scores analysis.
Conclusion: Metal mold-based spacers and silicone mold-based spacers demonstrate no significant differences in functional assessment (ROM, KSS, and WOMAC) or infection control. These findings indicate that silicone mold-based spacers may serve as a reliable alternative to conventional metal mold-based spacers, particularly in low-income countries.