Clinical Evaluation of Two-Stage Revision Total Knee Arthroplasty Using Silicone Mold-Based and Metal Mold-Based Antibiotic-Loaded Knee Spacers: A Comparative Study.

Q2 Medicine
Medical Journal of the Islamic Republic of Iran Pub Date : 2026-05-23 eCollection Date: 2026-01-01 DOI:10.47176/mjiri.40.51
Mohamad Amin Younessi Heravi, Reza Ganji, Ismaeil Garivani, Negin Armide
{"title":"Clinical Evaluation of Two-Stage Revision Total Knee Arthroplasty Using Silicone Mold-Based and Metal Mold-Based Antibiotic-Loaded Knee Spacers: A Comparative Study.","authors":"Mohamad Amin Younessi Heravi, Reza Ganji, Ismaeil Garivani, Negin Armide","doi":"10.47176/mjiri.40.51","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The gold standard for managing infection following total knee arthroplasty (TKA) is two-stage revision surgery, which entails the placement of a spacer in the knee during the initial stage. This study aimed to compare metal mold-based and silicone mold-based spacers regarding clinical evaluation and infection control in patients with infected TKAs.</p><p><strong>Methods: </strong>In this study, we assigned fourteen individuals with infected knees following arthroplasty to either the metal mold-based spacer group (control) or the silicon mold-based spacer group. The WOMAC Score, Knee Society Score (KSS), and range of motion (ROM) were utilized for clinical evaluation prior to spacer implantation and during the post-first stage of surgery follow-up. Gain score analysis (post-pre difference) was conducted to assess functional improvement over time. The Wilcoxon signed-rank test and the Mann-Whitney U test were applied for statistical analysis using SPSS software.</p><p><strong>Results: </strong>Knee infection was eliminated in all participants across both groups. Post-surgery, ROM improved from 59.28 ± 20.29° to 99.00 ± 5.65° in the control group, while the intervention group demonstrated an increase in ROM from 66.42 ± 24.78° to 101.42 ± 8.01°. Additionally, the KSS improved from 38.28 ± 23.78 to 123.71 ± 20.53 in the control group and from 35.71 ± 30.99 to 124.85 ± 27.49 in the intervention group. The WOMAC score increased from 48.71 ± 9.23 to 70.57 ± 5.28 in the control group and from 47.71 ± 12.03 to 72.57 ± 6.32 in the intervention group. There were no statistically significant differences between the two groups in terms of ROM (<i>P</i> = 0.751), WOMAC (<i>P</i> = 0.678), or KSS (<i>P</i> = 0.806) in the gain scores analysis.</p><p><strong>Conclusion: </strong>Metal mold-based spacers and silicone mold-based spacers demonstrate no significant differences in functional assessment (ROM, KSS, and WOMAC) or infection control. These findings indicate that silicone mold-based spacers may serve as a reliable alternative to conventional metal mold-based spacers, particularly in low-income countries.</p>","PeriodicalId":18361,"journal":{"name":"Medical Journal of the Islamic Republic of Iran","volume":"40 ","pages":"51"},"PeriodicalIF":0.0000,"publicationDate":"2026-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13403875/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Journal of the Islamic Republic of Iran","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47176/mjiri.40.51","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The gold standard for managing infection following total knee arthroplasty (TKA) is two-stage revision surgery, which entails the placement of a spacer in the knee during the initial stage. This study aimed to compare metal mold-based and silicone mold-based spacers regarding clinical evaluation and infection control in patients with infected TKAs.

Methods: In this study, we assigned fourteen individuals with infected knees following arthroplasty to either the metal mold-based spacer group (control) or the silicon mold-based spacer group. The WOMAC Score, Knee Society Score (KSS), and range of motion (ROM) were utilized for clinical evaluation prior to spacer implantation and during the post-first stage of surgery follow-up. Gain score analysis (post-pre difference) was conducted to assess functional improvement over time. The Wilcoxon signed-rank test and the Mann-Whitney U test were applied for statistical analysis using SPSS software.

Results: Knee infection was eliminated in all participants across both groups. Post-surgery, ROM improved from 59.28 ± 20.29° to 99.00 ± 5.65° in the control group, while the intervention group demonstrated an increase in ROM from 66.42 ± 24.78° to 101.42 ± 8.01°. Additionally, the KSS improved from 38.28 ± 23.78 to 123.71 ± 20.53 in the control group and from 35.71 ± 30.99 to 124.85 ± 27.49 in the intervention group. The WOMAC score increased from 48.71 ± 9.23 to 70.57 ± 5.28 in the control group and from 47.71 ± 12.03 to 72.57 ± 6.32 in the intervention group. There were no statistically significant differences between the two groups in terms of ROM (P = 0.751), WOMAC (P = 0.678), or KSS (P = 0.806) in the gain scores analysis.

Conclusion: Metal mold-based spacers and silicone mold-based spacers demonstrate no significant differences in functional assessment (ROM, KSS, and WOMAC) or infection control. These findings indicate that silicone mold-based spacers may serve as a reliable alternative to conventional metal mold-based spacers, particularly in low-income countries.

硅胶模基和金属模基含抗生素膝关节垫片两期翻修全膝关节置换术的临床评价:比较研究。
背景:处理全膝关节置换术(TKA)后感染的金标准是两阶段翻修手术,这需要在初始阶段在膝关节内放置垫片。本研究旨在比较金属模具和硅胶模具在tka感染患者的临床评价和感染控制方面的差异。方法:在本研究中,我们将14例膝关节置换术后感染的患者分为金属模基垫片组(对照组)和硅模基垫片组。WOMAC评分、膝关节社会评分(KSS)和活动范围(ROM)用于垫片植入前和手术后第一阶段随访期间的临床评估。进行增益评分分析(前后差异)以评估功能随时间的改善。采用SPSS软件,采用Wilcoxon sign -rank检验和Mann-Whitney U检验进行统计分析。结果:两组所有参与者均消除了膝关节感染。术后,对照组ROM由59.28±20.29°改善至99.00±5.65°,干预组ROM由66.42±24.78°改善至101.42±8.01°。干预组KSS由35.71±30.99提高到124.85±27.49,对照组由38.28±23.78提高到123.71±20.53。对照组的WOMAC评分从48.71±9.23提高到70.57±5.28,干预组的WOMAC评分从47.71±12.03提高到72.57±6.32。两组在增益评分分析中ROM (P = 0.751)、WOMAC (P = 0.678)、KSS (P = 0.806)差异均无统计学意义。结论:金属基垫片和硅胶基垫片在功能评估(ROM、KSS和WOMAC)和感染控制方面无显著差异。这些发现表明,硅树脂基垫片可以作为传统金属基垫片的可靠替代品,特别是在低收入国家。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.40
自引率
0.00%
发文量
90
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书