{"title":"Impact of introduction of bubble CPAP on neonatal mortality in Tajikistan.","authors":"Manzura Mirsaidova, Zulfiya Abdusamatzoda, Shamshod Muzaffarov, Firuza Zakirova, Farida Olimova, Isoeva Mavjuda, Matluba Kosimova, Aziza Mamatova, Manizha Makhmudova, Nasiba Solieva, Daniel Woodhead, Steve Smith, Marcia Bennett, Mark A Underwood","doi":"10.1177/19345798261471904","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundPreterm infants with respiratory distress are at high risk of mortality in low-resource settings due to limited access to advanced respiratory support. Bubble Continuous Positive Airway Pressure (bCPAP) improves outcomes in preterm infants with respiratory distress but generally requires significant infrastructure (electricity and blended oxygen). We hypothesized that introduction of a novel bCPAP device (Vayu) that does not require electricity or a pressurized air source would improve survival of moderately preterm infants.MethodsIn this pilot observational cohort study, demographic and mortality data were collected for 2 months prior to and 14 months following introduction of Vayu bCPAP in 2024 at three hospitals in Tajikistan. Similar data were collected following introduction of bCPAP in four additional hospitals and compared to historical mortality data for those same hospitals from 2023. Finally, mortality was compared for all seven hospitals following introduction of bCPAP to historical data from 2023.ResultsFollowing introduction of bCPAP, survival improved in the three initial hospitals for infants with birth weight of 1000-1499 g and 1500-2499 g. In the second group of four hospitals, improved survival was seen in infants with birth weight of 500-999 g compared to historical data. Combined data from all seven hospitals showed improvement in mortality for infants with birth weight of 500-999 g and 1000-1499 g.ConclusionsbCPAP that does not require electricity or a pressurized air source was associated with improved survival in very preterm infants. Our data suggest feasibility and benefit in a central Asian country. Further studies of bCPAP in low-middle income countries are warranted.</p>","PeriodicalId":16537,"journal":{"name":"Journal of neonatal-perinatal medicine","volume":" ","pages":"19345798261471904"},"PeriodicalIF":1.0000,"publicationDate":"2026-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neonatal-perinatal medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19345798261471904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundPreterm infants with respiratory distress are at high risk of mortality in low-resource settings due to limited access to advanced respiratory support. Bubble Continuous Positive Airway Pressure (bCPAP) improves outcomes in preterm infants with respiratory distress but generally requires significant infrastructure (electricity and blended oxygen). We hypothesized that introduction of a novel bCPAP device (Vayu) that does not require electricity or a pressurized air source would improve survival of moderately preterm infants.MethodsIn this pilot observational cohort study, demographic and mortality data were collected for 2 months prior to and 14 months following introduction of Vayu bCPAP in 2024 at three hospitals in Tajikistan. Similar data were collected following introduction of bCPAP in four additional hospitals and compared to historical mortality data for those same hospitals from 2023. Finally, mortality was compared for all seven hospitals following introduction of bCPAP to historical data from 2023.ResultsFollowing introduction of bCPAP, survival improved in the three initial hospitals for infants with birth weight of 1000-1499 g and 1500-2499 g. In the second group of four hospitals, improved survival was seen in infants with birth weight of 500-999 g compared to historical data. Combined data from all seven hospitals showed improvement in mortality for infants with birth weight of 500-999 g and 1000-1499 g.ConclusionsbCPAP that does not require electricity or a pressurized air source was associated with improved survival in very preterm infants. Our data suggest feasibility and benefit in a central Asian country. Further studies of bCPAP in low-middle income countries are warranted.

引入气泡CPAP对塔吉克斯坦新生儿死亡率的影响。
背景:在资源匮乏的环境中,由于获得高级呼吸支持的机会有限,患有呼吸窘迫的早产儿死亡率很高。气泡持续气道正压通气(bCPAP)可改善呼吸窘迫早产儿的预后,但通常需要大量基础设施(电力和混合氧气)。我们假设引入一种不需要电或加压气源的新型bCPAP设备(Vayu)将提高中度早产儿的生存率。方法在这项前瞻性观察队列研究中,收集了塔吉克斯坦三家医院在2024年引入Vayu bCPAP前2个月和后14个月的人口统计学和死亡率数据。在另外四家医院引入bCPAP后,收集了类似的数据,并与这些医院自2023年以来的历史死亡率数据进行了比较。最后,将所有7家医院在引入bCPAP后的死亡率与2023年以来的历史数据进行比较。结果采用bCPAP后,出生体重在1000 ~ 1499 g和1500 ~ 2499 g的新生儿在三家初始医院的生存率均有所提高。在第二组四家医院中,与历史数据相比,出生体重在500-999克的婴儿存活率有所提高。所有七家医院的综合数据显示,出生体重为500-999克和1000-1499克的婴儿死亡率有所改善。结论:不需要电或加压气源的bcpap可提高极早产儿的存活率。我们的数据表明了在中亚国家的可行性和效益。中低收入国家bCPAP的进一步研究是有必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of neonatal-perinatal medicine
Journal of neonatal-perinatal medicine Medicine-Pediatrics, Perinatology and Child Health
CiteScore
2.00
自引率
0.00%
发文量
124
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书