Effect of graphene-based intracanal medicament on push-out bond strength of different endodontic sealers in root canal dentin - an in vitro study.

Biomaterial investigations in dentistry Pub Date : 2026-07-22 eCollection Date: 2026-01-01 DOI:10.2340/biid.v13.46558
Rathna Piriyanga, Manish Ranjan, Anand Sherwood
{"title":"Effect of graphene-based intracanal medicament on push-out bond strength of different endodontic sealers in root canal dentin - an in vitro study.","authors":"Rathna Piriyanga, Manish Ranjan, Anand Sherwood","doi":"10.2340/biid.v13.46558","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Graphene-based hydrogels incorporating antimicrobial agents, such as allicin and silver nanoparticles, offer potential therapeutic benefits. This study aimed to evaluate the effect of an allicin-incorporated graphene oxide-silver nanoparticle hydrogel on the push-out bond strength of endodontic sealers and the influence of different removal protocols.</p><p><strong>Materials and methods: </strong>A total of 60 extracted human single-rooted teeth were prepared to F3 size protaper and irrigated with 3% sodium hypochlorite and 17% Ethylenediaminetetraacetic Acid (EDTA) The experimental hydrogel (allicin + graphene oxide + silver nanoparticles in 2% sodium alginate base) was placed in all canals and incubated for 7 days. Specimens were randomised by sealer type (AH Plus, Mineral Trioxide Aggregate (MTA) Fillapex, Sealapex) and removal protocol: syringe irrigation, passive ultrasonic irrigation (PUI), or XP-Endo Finisher activation. Push-out bond strength was measured using a universal testing machine. A subset of specimens (<i>n</i> = 3 per protocol) underwent Scanning Electron Microscopy (SEM)/Energy Dispersive X-ray Spectroscopy (EDX) analysis to evaluate residual medicament. Data were statistically analysed.</p><p><strong>Results: </strong>Push-out bond strength was significantly influenced by both sealer type and removal protocol (<i>p</i> < 0.05). AH Plus exhibited the highest bond strength (mean ± standard deviation [SD]: 5.2 ± 1.4 MPa), followed by Sealapex (1.9 ± 0.3 MPa) and MTA Fillapex (1.5 ± 0.4 MPa). Activation-assisted protocols (PUI: 4.8 ± 1.2 MPa; XP-Endo Finisher: 5.0 ± 1.3 MPa) significantly increased bond strength compared to syringe irrigation alone (3.1 ± 1.0 MPa; <i>p</i> < 0.05). SEM/EDX analysis revealed minimal residual hydrogel after activation, without adversely affecting sealer adhesion. Bond strength was highest in the cervical third and lowest in the apical third (<i>p</i> < 0.05).</p><p><strong>Conclusion: </strong>The allicin-incorporated graphene oxide-silver nanoparticle hydrogel did not compromise the push-out bond strength of the evaluated endodontic sealers when appropriate medicament removal protocols were employed. PUI and XP-Endo Finisher activation effectively facilitated hydrogel removal and maintained sealer adhesion, supporting the potential use of this material as an intracanal medicament.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":"13 ","pages":"46558"},"PeriodicalIF":0.0000,"publicationDate":"2026-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13401214/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2340/biid.v13.46558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Graphene-based hydrogels incorporating antimicrobial agents, such as allicin and silver nanoparticles, offer potential therapeutic benefits. This study aimed to evaluate the effect of an allicin-incorporated graphene oxide-silver nanoparticle hydrogel on the push-out bond strength of endodontic sealers and the influence of different removal protocols.

Materials and methods: A total of 60 extracted human single-rooted teeth were prepared to F3 size protaper and irrigated with 3% sodium hypochlorite and 17% Ethylenediaminetetraacetic Acid (EDTA) The experimental hydrogel (allicin + graphene oxide + silver nanoparticles in 2% sodium alginate base) was placed in all canals and incubated for 7 days. Specimens were randomised by sealer type (AH Plus, Mineral Trioxide Aggregate (MTA) Fillapex, Sealapex) and removal protocol: syringe irrigation, passive ultrasonic irrigation (PUI), or XP-Endo Finisher activation. Push-out bond strength was measured using a universal testing machine. A subset of specimens (n = 3 per protocol) underwent Scanning Electron Microscopy (SEM)/Energy Dispersive X-ray Spectroscopy (EDX) analysis to evaluate residual medicament. Data were statistically analysed.

Results: Push-out bond strength was significantly influenced by both sealer type and removal protocol (p < 0.05). AH Plus exhibited the highest bond strength (mean ± standard deviation [SD]: 5.2 ± 1.4 MPa), followed by Sealapex (1.9 ± 0.3 MPa) and MTA Fillapex (1.5 ± 0.4 MPa). Activation-assisted protocols (PUI: 4.8 ± 1.2 MPa; XP-Endo Finisher: 5.0 ± 1.3 MPa) significantly increased bond strength compared to syringe irrigation alone (3.1 ± 1.0 MPa; p < 0.05). SEM/EDX analysis revealed minimal residual hydrogel after activation, without adversely affecting sealer adhesion. Bond strength was highest in the cervical third and lowest in the apical third (p < 0.05).

Conclusion: The allicin-incorporated graphene oxide-silver nanoparticle hydrogel did not compromise the push-out bond strength of the evaluated endodontic sealers when appropriate medicament removal protocols were employed. PUI and XP-Endo Finisher activation effectively facilitated hydrogel removal and maintained sealer adhesion, supporting the potential use of this material as an intracanal medicament.

石墨烯基管内药物对不同根管封闭剂牙本质推出结合强度的影响——体外研究。
介绍:石墨烯基水凝胶结合抗菌剂,如大蒜素和纳米银,提供潜在的治疗效益。本研究旨在评估大蒜素氧化石墨烯-银纳米颗粒水凝胶对牙髓密封剂推出结合强度的影响以及不同去除方案的影响。材料与方法:将60颗拔除的人单根牙齿制备成F3大小的protaper,用3%次氯酸钠和17%乙二胺四乙酸(EDTA)冲洗。实验水凝胶(蒜素+氧化石墨烯+银纳米颗粒,2%海藻酸钠碱)放置于所有管中,孵育7 d。标本按密封剂类型(AH Plus、Mineral Trioxide Aggregate (MTA) Fillapex、Sealapex)和去除方案(注射器冲洗、被动超声冲洗(PUI)或XP-Endo Finisher激活)随机分组。推出粘结强度采用万能试验机测量。一个样本子集(每个方案n = 3)进行扫描电子显微镜(SEM)/能量色散x射线光谱(EDX)分析以评估残留药物。对资料进行统计学分析。结果:封口剂类型和拔除方式对推出粘结强度均有显著影响(p < 0.05)。AH Plus的结合强度最高(平均±标准差[SD]: 5.2±1.4 MPa),其次是Sealapex(1.9±0.3 MPa)和MTA Fillapex(1.5±0.4 MPa)。激活辅助方案(PUI: 4.8±1.2 MPa; XP-Endo Finisher: 5.0±1.3 MPa)与单独注射器冲洗(3.1±1.0 MPa; p < 0.05)相比,显著提高了粘结强度。SEM/EDX分析显示,活化后的水凝胶残留量极小,不会对密封剂的附着力产生不利影响。粘结强度在颈三分之一处最高,在根尖三分之一处最低(p < 0.05)。结论:当采用适当的药物去除方案时,大蒜素掺入的氧化石墨烯-银纳米颗粒水凝胶不会影响所评估的根管密封剂的推出结合强度。PUI和XP-Endo Finisher的活化有效地促进了水凝胶的去除,并保持了密封剂的粘附性,支持了该材料作为肛管内药物的潜在用途。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书