Ryan S. Donnelly, Theodore J. Gerard, Sebastian M. Krajewski, Brandon Q. Mercado, Xiaoping Wang* and Patrick L. Holland*,
{"title":"Hydride and Seek: Comparing Crystallographic Hydride Placement Techniques with an Open-Shell Cobalt Complex","authors":"Ryan S. Donnelly, Theodore J. Gerard, Sebastian M. Krajewski, Brandon Q. Mercado, Xiaoping Wang* and Patrick L. Holland*, ","doi":"10.1021/acscentsci.6c00632","DOIUrl":null,"url":null,"abstract":"<p>Locating hydrides\r\nis crucial in organometallic chemistry\r\nbut difficult\r\nto do accurately using X-ray diffraction. Electron diffraction has\r\nbeen proposed as a way to overcome this problem but has not been systematically\r\ncompared to neutron diffraction and to quantum crystallography (Hirshfeld\r\natom refinement, HAR) to test this hypothesis. Here, we present a\r\ncomparative analysis of methods for a terminal cobalt hydride complex\r\nby comparing a single-crystal neutron diffraction reference structure\r\nto results from single-crystal X-ray diffraction with and without\r\nHirshfeld atom refinement (HAR, NoSpherA2), density functional theory\r\n(DFT), and electron diffraction (3D-ED/MicroED) refined under kinematical\r\nand dynamical formalisms. Conventional X-ray diffraction gives lower\r\nprecision than neutron diffraction as expected. Despite expected improvements,\r\nHAR gives systematic deviation from the neutron benchmark. Interestingly,\r\noptimized DFT equilibrium geometries are closer to the neutron value\r\nthan the value from HAR. On the other hand, electron diffraction with\r\na high-quality data set coupled with dynamical refinement localizes\r\nthe hydride in difference maps and gives excellent agreement with\r\nthe neutron data. Dynamical refinement is crucial, as kinematical\r\nrefinement does not allow assignment of a hydride peak. This cross-modal\r\ncomparison defines the conditions under which 3D-ED/MicroED delivers\r\nhigh-precision metal–hydride distances for this open-shell\r\ncobalt hydride.</p>","PeriodicalId":10,"journal":{"name":"ACS Central Science","volume":"12 7","pages":"972–980"},"PeriodicalIF":11.1000,"publicationDate":"2026-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Central Science","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acscentsci.6c00632","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Locating hydrides
is crucial in organometallic chemistry
but difficult
to do accurately using X-ray diffraction. Electron diffraction has
been proposed as a way to overcome this problem but has not been systematically
compared to neutron diffraction and to quantum crystallography (Hirshfeld
atom refinement, HAR) to test this hypothesis. Here, we present a
comparative analysis of methods for a terminal cobalt hydride complex
by comparing a single-crystal neutron diffraction reference structure
to results from single-crystal X-ray diffraction with and without
Hirshfeld atom refinement (HAR, NoSpherA2), density functional theory
(DFT), and electron diffraction (3D-ED/MicroED) refined under kinematical
and dynamical formalisms. Conventional X-ray diffraction gives lower
precision than neutron diffraction as expected. Despite expected improvements,
HAR gives systematic deviation from the neutron benchmark. Interestingly,
optimized DFT equilibrium geometries are closer to the neutron value
than the value from HAR. On the other hand, electron diffraction with
a high-quality data set coupled with dynamical refinement localizes
the hydride in difference maps and gives excellent agreement with
the neutron data. Dynamical refinement is crucial, as kinematical
refinement does not allow assignment of a hydride peak. This cross-modal
comparison defines the conditions under which 3D-ED/MicroED delivers
high-precision metal–hydride distances for this open-shell
cobalt hydride.
期刊介绍:
ACS Central Science publishes significant primary reports on research in chemistry and allied fields where chemical approaches are pivotal. As the first fully open-access journal by the American Chemical Society, it covers compelling and important contributions to the broad chemistry and scientific community. "Central science," a term popularized nearly 40 years ago, emphasizes chemistry's central role in connecting physical and life sciences, and fundamental sciences with applied disciplines like medicine and engineering. The journal focuses on exceptional quality articles, addressing advances in fundamental chemistry and interdisciplinary research.