Robotic Aortic Valve Replacement in Severe Scoliosis with Markedly Narrow Chest.

IF 0.7 Q4 SURGERY
Surgical Case Reports Pub Date : 2026-01-01 Epub Date: 2026-07-22 DOI:10.70352/scrj.cr.26-0336
Sayaka Honda, Naonori Kawamoto, Yuki Tadokoro, Rieko Kutsuzawa, Ayumi Ikuta, Takashi Kakuta, Kota Suzuki, Kizuku Yamashita, Satsuki Fukushima
{"title":"Robotic Aortic Valve Replacement in Severe Scoliosis with Markedly Narrow Chest.","authors":"Sayaka Honda, Naonori Kawamoto, Yuki Tadokoro, Rieko Kutsuzawa, Ayumi Ikuta, Takashi Kakuta, Kota Suzuki, Kizuku Yamashita, Satsuki Fukushima","doi":"10.70352/scrj.cr.26-0336","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Robotic-assisted aortic valve replacement (AVR) has emerged as an extension of minimally invasive cardiac surgery, offering enhanced visualization and articulated instrument control. However, patients with severe thoracic deformities and markedly narrow chest anatomy are generally considered challenging candidates because restricted operative space may compromise annular exposure, instrument maneuverability, and aortotomy closure. Reports describing robotic-assisted AVR in such patients remain limited. We describe a successful robotic-assisted AVR in a patient with severe scoliosis and a markedly narrow thoracic cavity, highlighting technical modifications that enabled safe valve implantation.</p><p><strong>Case presentation: </strong>A 61-year-old man presented with progressive exertional dyspnea and fatigue caused by severe aortic regurgitation. CT demonstrated severe scoliosis with marked narrowing of the thoracic cavity, resulting in a sternovertebral distance of 6.5 cm. The patient also had a stable chronic type B aortic dissection extending from the descending thoracic aorta to the level of the superior mesenteric artery without involvement of the ascending aorta or aortic arch. After multidisciplinary discussion and informed consent, robotic-assisted AVR was performed using the da Vinci Xi system (Intuitive Surgical, Sunnyvale, CA, USA). Technical modifications included the placement of the service-port robotic arm in the fifth intercostal space to improve the working angle and avoid arm interference, and the creation of a longitudinal aortotomy to facilitate valve exposure in the restricted operative field. Exposure of the noncoronary and left coronary annulus was achieved through robotic retraction and bedside suction assistance. A 23-mm bioprosthetic valve was successfully implanted without intraoperative complications. The patient was extubated within 5 h and discharged on POD 20. Postoperative echocardiography demonstrated normal prosthetic valve function without paravalvular leakage.</p><p><strong>Conclusions: </strong>Robotic-assisted AVR may be feasible in carefully selected patients with scoliosis-associated narrow chest anatomy. Detailed preoperative assessment and tailored technical strategies, including longitudinal aortotomy and modified port placement, may facilitate adequate exposure and safe valve implantation in anatomically challenging cases.</p>","PeriodicalId":22096,"journal":{"name":"Surgical Case Reports","volume":"12 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13395559/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70352/scrj.cr.26-0336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/22 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Robotic-assisted aortic valve replacement (AVR) has emerged as an extension of minimally invasive cardiac surgery, offering enhanced visualization and articulated instrument control. However, patients with severe thoracic deformities and markedly narrow chest anatomy are generally considered challenging candidates because restricted operative space may compromise annular exposure, instrument maneuverability, and aortotomy closure. Reports describing robotic-assisted AVR in such patients remain limited. We describe a successful robotic-assisted AVR in a patient with severe scoliosis and a markedly narrow thoracic cavity, highlighting technical modifications that enabled safe valve implantation.

Case presentation: A 61-year-old man presented with progressive exertional dyspnea and fatigue caused by severe aortic regurgitation. CT demonstrated severe scoliosis with marked narrowing of the thoracic cavity, resulting in a sternovertebral distance of 6.5 cm. The patient also had a stable chronic type B aortic dissection extending from the descending thoracic aorta to the level of the superior mesenteric artery without involvement of the ascending aorta or aortic arch. After multidisciplinary discussion and informed consent, robotic-assisted AVR was performed using the da Vinci Xi system (Intuitive Surgical, Sunnyvale, CA, USA). Technical modifications included the placement of the service-port robotic arm in the fifth intercostal space to improve the working angle and avoid arm interference, and the creation of a longitudinal aortotomy to facilitate valve exposure in the restricted operative field. Exposure of the noncoronary and left coronary annulus was achieved through robotic retraction and bedside suction assistance. A 23-mm bioprosthetic valve was successfully implanted without intraoperative complications. The patient was extubated within 5 h and discharged on POD 20. Postoperative echocardiography demonstrated normal prosthetic valve function without paravalvular leakage.

Conclusions: Robotic-assisted AVR may be feasible in carefully selected patients with scoliosis-associated narrow chest anatomy. Detailed preoperative assessment and tailored technical strategies, including longitudinal aortotomy and modified port placement, may facilitate adequate exposure and safe valve implantation in anatomically challenging cases.

机器人主动脉瓣置换术治疗重度脊柱侧凸伴明显胸窄。
机器人辅助主动脉瓣置换术(AVR)已成为微创心脏手术的延伸,提供增强的可视化和铰接式仪器控制。然而,严重的胸部畸形和明显狭窄的胸部解剖结构的患者通常被认为是具有挑战性的候选人,因为受限的手术空间可能会影响环暴露,器械的可操作性和主动脉切开术的关闭。关于机器人辅助AVR在这类患者中的应用的报道仍然有限。我们描述了一个成功的机器人辅助AVR患者严重脊柱侧凸和明显狭窄的胸腔,强调技术改进,使安全的瓣膜植入。病例介绍:一名61岁男性,因严重主动脉反流导致进行性用力呼吸困难和疲劳。CT显示严重的脊柱侧凸伴明显的胸腔狭窄,导致胸椎距离为6.5 cm。患者也有稳定的慢性B型主动脉夹层,从胸降主动脉延伸至肠系膜上动脉水平,未累及升主动脉或主动脉弓。在多学科讨论和知情同意后,使用达芬奇Xi系统(Intuitive Surgical, Sunnyvale, CA, USA)进行机器人辅助AVR。技术改进包括将服务端口机械臂放置在第五肋间隙,以改善工作角度并避免手臂干扰,并创建纵向主动脉切开术,以方便在受限的手术视野中暴露瓣膜。非冠状动脉和左冠状动脉环的暴露是通过机器人牵拉和床边吸引辅助实现的。成功植入23mm生物假体瓣膜,无术中并发症。患者于5小时内拔管出院。术后超声心动图显示人工瓣膜功能正常,无瓣旁渗漏。结论:机器人辅助AVR在精心挑选的脊柱侧凸相关窄胸解剖患者中是可行的。详细的术前评估和量身定制的技术策略,包括纵向主动脉切开术和改良的端口放置,可能有助于在解剖困难的病例中进行充分的暴露和安全的瓣膜植入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
218
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书