[Surgical approaches to different foreign bodies in the urinary bladder: A report of 2 cases].

Q3 Medicine
北京大学学报(医学版) Pub Date : 2026-08-18
Shen Wang, Xinyi Song, Xiaona Sun, Jilu Zheng, Ji Lv
{"title":"[Surgical approaches to different foreign bodies in the urinary bladder: A report of 2 cases].","authors":"Shen Wang, Xinyi Song, Xiaona Sun, Jilu Zheng, Ji Lv","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We reported the clinical records of 2 patients each with a foreign body in the urinary bladder admitted to Qingdao Central Hospital, University of Health and Rehabilitation Sciences. The size and shape of each foreign body in the urinary bladder were different, thus we chose different surgical approaches to remove them. Case 1 was a 21-year-old male patient. He presented to the outpatient service with urodynia. The patient currently complained of urodynia, and narrated that a foreign body was self-inserted <i>via</i> the urethra 2 days before. Physical examination revealed suprapubic pain. Ultimately he was admitted to the Department of Urology with a diagnosis of \"bladder foreign body\". A computed tomography (CT) scan of the pelvis was performed and the results demonstrated a linear metallic structure, mea-suring 4.2 cm in length, within the urinary bladder. Under general anesthesia, the patient was placed in lithotomy position and a rigid cystoscope was inserted into the bladder <i>via</i> urethra. The foreign body was a metal tubular structure and was located within the urinary bladder. Removal by foreign body forceps was attempted and long axis of the foreign body should be parallel to cystoscope. Removal was carefully performed after several attempts due to the smooth surface of the metal foreign body. Case 2 was a 42-year-old male patient. He presented to the outpatient service with dysuria and urodynia and was admitted to the Department of Urology. The patient narrated that a foreign body was self-inserted <i>via</i> the urethra 1 day before, and currently complained of dysuria, urodynia, and slight hematuria. A CT scan of the urologic system was performed and the results demonstrated a metal tubular structure, measuring 21.5 cm in length. The length of the foreign body was long (from top of iliac crest to perineum) and both ends were sharp, thus bladder perforation could not be excluded. Besides, with smooth metal surface, it was difficult to remove <i>via</i> cystoscopy and the risk of iatrogenic bladder perforation would increase simultaneously. Therefore, laparoscopic surgery was chosen to detect whether there would be a bladder perforation and could remove the foreign body. Under general anesthesia, the patient was placed in supine position and supraumbilical incision of 1 cm was performed. Pneumoperitoneum needle was used to establish a pneumoperitoneum and insufflation CO<sub>2</sub> pressure was maintained at 12 mmHg. The peritoneum was accessed and a 10-mm trocar and laparoscopic camera were inserted. A 5-mm trocar was inserted at 2 cm below the umbilical level of lateral margin of left rectus abdominis muscle. While a 12-mm trocar was inserted at symmetrical site of his right rectus abdominis muscle. Under laparoscope, dome of the bladder was lifted into the abdominal cavity by the foreign body, then the bladder wall was incised to expose the foreign body. We pushed the bottom of the foreign body from the perineum extracorporally and removed the foreign body from the supraumbilicus trocar.</p>","PeriodicalId":8790,"journal":{"name":"北京大学学报(医学版)","volume":"58 4","pages":"877-880"},"PeriodicalIF":0.0000,"publicationDate":"2026-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13402077/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"北京大学学报(医学版)","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

We reported the clinical records of 2 patients each with a foreign body in the urinary bladder admitted to Qingdao Central Hospital, University of Health and Rehabilitation Sciences. The size and shape of each foreign body in the urinary bladder were different, thus we chose different surgical approaches to remove them. Case 1 was a 21-year-old male patient. He presented to the outpatient service with urodynia. The patient currently complained of urodynia, and narrated that a foreign body was self-inserted via the urethra 2 days before. Physical examination revealed suprapubic pain. Ultimately he was admitted to the Department of Urology with a diagnosis of "bladder foreign body". A computed tomography (CT) scan of the pelvis was performed and the results demonstrated a linear metallic structure, mea-suring 4.2 cm in length, within the urinary bladder. Under general anesthesia, the patient was placed in lithotomy position and a rigid cystoscope was inserted into the bladder via urethra. The foreign body was a metal tubular structure and was located within the urinary bladder. Removal by foreign body forceps was attempted and long axis of the foreign body should be parallel to cystoscope. Removal was carefully performed after several attempts due to the smooth surface of the metal foreign body. Case 2 was a 42-year-old male patient. He presented to the outpatient service with dysuria and urodynia and was admitted to the Department of Urology. The patient narrated that a foreign body was self-inserted via the urethra 1 day before, and currently complained of dysuria, urodynia, and slight hematuria. A CT scan of the urologic system was performed and the results demonstrated a metal tubular structure, measuring 21.5 cm in length. The length of the foreign body was long (from top of iliac crest to perineum) and both ends were sharp, thus bladder perforation could not be excluded. Besides, with smooth metal surface, it was difficult to remove via cystoscopy and the risk of iatrogenic bladder perforation would increase simultaneously. Therefore, laparoscopic surgery was chosen to detect whether there would be a bladder perforation and could remove the foreign body. Under general anesthesia, the patient was placed in supine position and supraumbilical incision of 1 cm was performed. Pneumoperitoneum needle was used to establish a pneumoperitoneum and insufflation CO2 pressure was maintained at 12 mmHg. The peritoneum was accessed and a 10-mm trocar and laparoscopic camera were inserted. A 5-mm trocar was inserted at 2 cm below the umbilical level of lateral margin of left rectus abdominis muscle. While a 12-mm trocar was inserted at symmetrical site of his right rectus abdominis muscle. Under laparoscope, dome of the bladder was lifted into the abdominal cavity by the foreign body, then the bladder wall was incised to expose the foreign body. We pushed the bottom of the foreign body from the perineum extracorporally and removed the foreign body from the supraumbilicus trocar.

膀胱内不同异物的手术入路(附2例报告)
我们报告了青岛卫生与康复大学附属中心医院收治的2例膀胱异物患者的临床资料。每个膀胱异物的大小和形状都不同,因此我们选择了不同的手术方式来清除它们。病例1为21岁男性患者。他以尿痛就诊于门诊。患者目前主诉尿痛,并叙述2天前自己通过尿道插入异物。体检发现耻骨上疼痛。最终,他被诊断为“膀胱异物”,住进了泌尿科。骨盆的计算机断层扫描(CT)结果显示膀胱内有一个线性金属结构,长度为4.2厘米。全麻下取取取石位,经尿道将刚性膀胱镜插入膀胱。异物为金属管状结构,位于膀胱内。尝试用异物钳取出异物,异物长轴应与膀胱镜平行。由于金属异物表面光滑,多次尝试后小心地取出。病例2为一名42岁男性患者。他以排尿困难和尿痛就诊于门诊,并被泌尿外科收治。患者自述1天前自己经尿道插入异物,现主诉排尿困难、尿痛及轻微血尿。对泌尿系统进行了CT扫描,结果显示一个金属管状结构,长度为21.5厘米。异物长度较长(自髂骨顶部至会阴),两端锋利,不排除膀胱穿孔。此外,金属表面光滑,难以通过膀胱镜切除,医源性膀胱穿孔的风险也会增加。因此,选择腹腔镜手术,以检测是否会有膀胱穿孔,并能取出异物。全麻下,患者取仰卧位,脐上切口1cm。使用气腹针建立气腹,维持CO2气压在12 mmHg。进入腹膜,插入10毫米套管针和腹腔镜相机。在左腹直肌外侧缘脐下2 cm处置入5 mm套管针。同时在右腹直肌对称部位插入12mm套管针。腹腔镜下,异物将膀胱穹窿提入腹腔,切开膀胱壁暴露异物。我们从会阴部外推异物底部并从脐上套管针取出异物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
北京大学学报(医学版)
北京大学学报(医学版) Medicine-Medicine (all)
CiteScore
0.80
自引率
0.00%
发文量
9815
期刊介绍: Beijing Da Xue Xue Bao Yi Xue Ban / Journal of Peking University (Health Sciences), established in 1959, is a national academic journal sponsored by Peking University, and its former name is Journal of Beijing Medical University. The coverage of the Journal includes basic medical sciences, clinical medicine, oral medicine, surgery, public health and epidemiology, pharmacology and pharmacy. Over the last few years, the Journal has published articles and reports covering major topics in the different special issues (e.g. research on disease genome, theory of drug withdrawal, mechanism and prevention of cardiovascular and cerebrovascular diseases, stomatology, orthopaedic, public health, urology and reproductive medicine). All the topics involve latest advances in medical sciences, hot topics in specific specialties, and prevention and treatment of major diseases. The Journal has been indexed and abstracted by PubMed Central (PMC), MEDLINE/PubMed, EBSCO, Embase, Scopus, Chemical Abstracts (CA), Western Pacific Region Index Medicus (WPR), JSTChina, and almost all the Chinese sciences and technical index systems, including Chinese Science and Technology Paper Citation Database (CSTPCD), Chinese Science Citation Database (CSCD), China BioMedical Bibliographic Database (CBM), CMCI, Chinese Biological Abstracts, China National Academic Magazine Data-Base (CNKI), Wanfang Data (ChinaInfo), etc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书