Rose D Nolen-Walston, Caitrin R Lowndes, Jeaneen C Kulp, Daniela Luethy, Darko Stefanovski, Andrew W Van Eps
{"title":"Evaluation of an Immunoturbidometric Assay for Measurement of Total Adiponectin Concentration in Equine Serum Samples.","authors":"Rose D Nolen-Walston, Caitrin R Lowndes, Jeaneen C Kulp, Daniela Luethy, Darko Stefanovski, Andrew W Van Eps","doi":"10.1111/vcp.70118","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Total adiponectin (TA) is a marker of metabolic health in equids, with values below a critical decision point of < 7.9 μg/mL conferring increased risk of laminitis.</p><p><strong>Objectives: </strong>To evaluate an IT assay to measure serum [TA] in equids and to assess its correlation with [high molecular weight adiponectin] (HMWA) measured by ELISA.</p><p><strong>Methods: </strong>Total serum adiponectin concentrations from 207 adult horses were measured using both an IT assay for TA and HMWA using a previously validated ELISA assay. Data were analyzed using Spearman correlation and Passing-Bablok regression. Intra- and inter-assay precision, linearity, lower limit of quantification (LLoQ), and freeze-thaw stability were assessed for the [TA] assay.</p><p><strong>Results: </strong>Mean (range) intra-assay coefficient of variation (CV%) was 2.3% (1.8%-2.8%); inter-assay, across-day CV% was 3.3% (3.25%-3.4%), and across reagent lot CV was 11.7% (9.0%-17.9%). Mean recovery upon dilution was 133.7% (122.6%-140.6%), and LLoQ 1.3 μg/mL. The median CV for 5 freeze-thaw cycles was 3.0% (range 1.0%-3.0%) with a median change in concentration of -11% (range -[9.9-17.1]%). A strong correlation between [TA] and [HMWA] is observed (ρ = 0.90 [95% confidence interval 0.86-0.92], p < 0.001), although in 18% of samples, [HMWA] > [TA].</p><p><strong>Conclusions: </strong>The turbidimetric immunoassay is sufficiently precise and reliable for measurement of [TA] in equids, especially around the critical decision point, and LLoQ was below the lowest clinical cut-off value. [TA] overall correlated well with [HMWA] in this population, although instances of higher [HMWA] than [TA] were noted at high [HMWA].</p>","PeriodicalId":23593,"journal":{"name":"Veterinary clinical pathology","volume":" ","pages":"239-245"},"PeriodicalIF":1.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13686539/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary clinical pathology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vcp.70118","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Total adiponectin (TA) is a marker of metabolic health in equids, with values below a critical decision point of < 7.9 μg/mL conferring increased risk of laminitis.
Objectives: To evaluate an IT assay to measure serum [TA] in equids and to assess its correlation with [high molecular weight adiponectin] (HMWA) measured by ELISA.
Methods: Total serum adiponectin concentrations from 207 adult horses were measured using both an IT assay for TA and HMWA using a previously validated ELISA assay. Data were analyzed using Spearman correlation and Passing-Bablok regression. Intra- and inter-assay precision, linearity, lower limit of quantification (LLoQ), and freeze-thaw stability were assessed for the [TA] assay.
Results: Mean (range) intra-assay coefficient of variation (CV%) was 2.3% (1.8%-2.8%); inter-assay, across-day CV% was 3.3% (3.25%-3.4%), and across reagent lot CV was 11.7% (9.0%-17.9%). Mean recovery upon dilution was 133.7% (122.6%-140.6%), and LLoQ 1.3 μg/mL. The median CV for 5 freeze-thaw cycles was 3.0% (range 1.0%-3.0%) with a median change in concentration of -11% (range -[9.9-17.1]%). A strong correlation between [TA] and [HMWA] is observed (ρ = 0.90 [95% confidence interval 0.86-0.92], p < 0.001), although in 18% of samples, [HMWA] > [TA].
Conclusions: The turbidimetric immunoassay is sufficiently precise and reliable for measurement of [TA] in equids, especially around the critical decision point, and LLoQ was below the lowest clinical cut-off value. [TA] overall correlated well with [HMWA] in this population, although instances of higher [HMWA] than [TA] were noted at high [HMWA].
期刊介绍:
Veterinary Clinical Pathology is the official journal of the American Society for Veterinary Clinical Pathology (ASVCP) and the European Society of Veterinary Clinical Pathology (ESVCP). The journal''s mission is to provide an international forum for communication and discussion of scientific investigations and new developments that advance the art and science of laboratory diagnosis in animals. Veterinary Clinical Pathology welcomes original experimental research and clinical contributions involving domestic, laboratory, avian, and wildlife species in the areas of hematology, hemostasis, immunopathology, clinical chemistry, cytopathology, surgical pathology, toxicology, endocrinology, laboratory and analytical techniques, instrumentation, quality assurance, and clinical pathology education.