Deborah Carrick, Mitchell Ashton, Joshua Bognar, Natalia Diaz, James Rogers, Daniel Serra, Daniel Schick
{"title":"Utilisation of Objective and Subjective Image Quality Metrics to Guide Optimal Contrast Volumes for Abdominal CT.","authors":"Deborah Carrick, Mitchell Ashton, Joshua Bognar, Natalia Diaz, James Rogers, Daniel Serra, Daniel Schick","doi":"10.1002/jmrs.70113","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Determining the appropriate volume of iodinated contrast media (ICM) for portal venous phase abdominal computed tomography (CT) remains challenging. Evidence is limited regarding the volume required for consistent enhancement and whether this translates into optimal subjective image quality. To address this gap, we compared fixed-volume and weight-based dosing strategies, utilising objective enhancement and subjective image quality to identify approaches that may optimise diagnostic performance.</p><p><strong>Method: </strong>The abdominal CT ICM dosing protocol was revised from fixed (100 mL) to weight-based (1 mL/kg, 10 kg increments) volume dosing. Data from 90 fixed and 90 weight-based ICM volume procedures were matched by age, gender, weight and kVp. Objective measures of ICM enhancement (Hounsfield unit, HU) were obtained in key vessels and organs. Subjective image quality scores were obtained from 24 cases per group, matched by weight and kVp, followed by visual grading characteristic (VGC) analysis.</p><p><strong>Results: </strong>Weight-based dosing reduced the dependence of key vessel and organ enhancement on patient size compared with fixed dosing. VGC analysis comparing patients < 90 kg and ≥ 90 kg suggests light patients require greater HU enhancement than heavy patients to achieve equal subjective image quality.</p><p><strong>Conclusion: </strong>Consistent HU enhancement across all patient sizes can be achieved by using weight-based ICM volume dosing in abdominal CT, although this does not necessarily translate to consistent subjective image quality. Our findings suggest that lighter patients may benefit from greater enhancement to achieve equivalent subjective image quality to larger patients, highlighting the need for further optimisation of ICM dose strategies beyond standard weight-based approaches.</p>","PeriodicalId":16382,"journal":{"name":"Journal of Medical Radiation Sciences","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13394332/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/jmrs.70113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Determining the appropriate volume of iodinated contrast media (ICM) for portal venous phase abdominal computed tomography (CT) remains challenging. Evidence is limited regarding the volume required for consistent enhancement and whether this translates into optimal subjective image quality. To address this gap, we compared fixed-volume and weight-based dosing strategies, utilising objective enhancement and subjective image quality to identify approaches that may optimise diagnostic performance.
Method: The abdominal CT ICM dosing protocol was revised from fixed (100 mL) to weight-based (1 mL/kg, 10 kg increments) volume dosing. Data from 90 fixed and 90 weight-based ICM volume procedures were matched by age, gender, weight and kVp. Objective measures of ICM enhancement (Hounsfield unit, HU) were obtained in key vessels and organs. Subjective image quality scores were obtained from 24 cases per group, matched by weight and kVp, followed by visual grading characteristic (VGC) analysis.
Results: Weight-based dosing reduced the dependence of key vessel and organ enhancement on patient size compared with fixed dosing. VGC analysis comparing patients < 90 kg and ≥ 90 kg suggests light patients require greater HU enhancement than heavy patients to achieve equal subjective image quality.
Conclusion: Consistent HU enhancement across all patient sizes can be achieved by using weight-based ICM volume dosing in abdominal CT, although this does not necessarily translate to consistent subjective image quality. Our findings suggest that lighter patients may benefit from greater enhancement to achieve equivalent subjective image quality to larger patients, highlighting the need for further optimisation of ICM dose strategies beyond standard weight-based approaches.
期刊介绍:
Journal of Medical Radiation Sciences (JMRS) is an international and multidisciplinary peer-reviewed journal that accepts manuscripts related to medical imaging / diagnostic radiography, radiation therapy, nuclear medicine, medical ultrasound / sonography, and the complementary disciplines of medical physics, radiology, radiation oncology, nursing, psychology and sociology. Manuscripts may take the form of: original articles, review articles, commentary articles, technical evaluations, case series and case studies. JMRS promotes excellence in international medical radiation science by the publication of contemporary and advanced research that encourages the adoption of the best clinical, scientific and educational practices in international communities. JMRS is the official professional journal of the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) and the New Zealand Institute of Medical Radiation Technology (NZIMRT).