Utilisation of Objective and Subjective Image Quality Metrics to Guide Optimal Contrast Volumes for Abdominal CT.

IF 2.1 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Deborah Carrick, Mitchell Ashton, Joshua Bognar, Natalia Diaz, James Rogers, Daniel Serra, Daniel Schick
{"title":"Utilisation of Objective and Subjective Image Quality Metrics to Guide Optimal Contrast Volumes for Abdominal CT.","authors":"Deborah Carrick, Mitchell Ashton, Joshua Bognar, Natalia Diaz, James Rogers, Daniel Serra, Daniel Schick","doi":"10.1002/jmrs.70113","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Determining the appropriate volume of iodinated contrast media (ICM) for portal venous phase abdominal computed tomography (CT) remains challenging. Evidence is limited regarding the volume required for consistent enhancement and whether this translates into optimal subjective image quality. To address this gap, we compared fixed-volume and weight-based dosing strategies, utilising objective enhancement and subjective image quality to identify approaches that may optimise diagnostic performance.</p><p><strong>Method: </strong>The abdominal CT ICM dosing protocol was revised from fixed (100 mL) to weight-based (1 mL/kg, 10 kg increments) volume dosing. Data from 90 fixed and 90 weight-based ICM volume procedures were matched by age, gender, weight and kVp. Objective measures of ICM enhancement (Hounsfield unit, HU) were obtained in key vessels and organs. Subjective image quality scores were obtained from 24 cases per group, matched by weight and kVp, followed by visual grading characteristic (VGC) analysis.</p><p><strong>Results: </strong>Weight-based dosing reduced the dependence of key vessel and organ enhancement on patient size compared with fixed dosing. VGC analysis comparing patients < 90 kg and ≥ 90 kg suggests light patients require greater HU enhancement than heavy patients to achieve equal subjective image quality.</p><p><strong>Conclusion: </strong>Consistent HU enhancement across all patient sizes can be achieved by using weight-based ICM volume dosing in abdominal CT, although this does not necessarily translate to consistent subjective image quality. Our findings suggest that lighter patients may benefit from greater enhancement to achieve equivalent subjective image quality to larger patients, highlighting the need for further optimisation of ICM dose strategies beyond standard weight-based approaches.</p>","PeriodicalId":16382,"journal":{"name":"Journal of Medical Radiation Sciences","volume":" ","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2026-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13394332/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/jmrs.70113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Determining the appropriate volume of iodinated contrast media (ICM) for portal venous phase abdominal computed tomography (CT) remains challenging. Evidence is limited regarding the volume required for consistent enhancement and whether this translates into optimal subjective image quality. To address this gap, we compared fixed-volume and weight-based dosing strategies, utilising objective enhancement and subjective image quality to identify approaches that may optimise diagnostic performance.

Method: The abdominal CT ICM dosing protocol was revised from fixed (100 mL) to weight-based (1 mL/kg, 10 kg increments) volume dosing. Data from 90 fixed and 90 weight-based ICM volume procedures were matched by age, gender, weight and kVp. Objective measures of ICM enhancement (Hounsfield unit, HU) were obtained in key vessels and organs. Subjective image quality scores were obtained from 24 cases per group, matched by weight and kVp, followed by visual grading characteristic (VGC) analysis.

Results: Weight-based dosing reduced the dependence of key vessel and organ enhancement on patient size compared with fixed dosing. VGC analysis comparing patients < 90 kg and ≥ 90 kg suggests light patients require greater HU enhancement than heavy patients to achieve equal subjective image quality.

Conclusion: Consistent HU enhancement across all patient sizes can be achieved by using weight-based ICM volume dosing in abdominal CT, although this does not necessarily translate to consistent subjective image quality. Our findings suggest that lighter patients may benefit from greater enhancement to achieve equivalent subjective image quality to larger patients, highlighting the need for further optimisation of ICM dose strategies beyond standard weight-based approaches.

利用客观和主观图像质量指标指导腹部CT的最佳造影剂体积。
导论:确定门静脉期腹部计算机断层扫描(CT)中碘化造影剂(ICM)的适当体积仍然具有挑战性。关于一致性增强所需的体积以及这是否转化为最佳主观图像质量的证据有限。为了解决这一差距,我们比较了固定体积和基于重量的给药策略,利用客观增强和主观图像质量来确定可能优化诊断性能的方法。方法:将腹部CT ICM给药方案由固定给药(100ml)改为体重给药(1ml /kg,增量10kg)。来自90个固定和90个基于体重的ICM体积手术的数据根据年龄、性别、体重和kVp进行匹配。在关键血管和器官中获得ICM增强的客观测量(Hounsfield单位,HU)。每组24例获得主观图像质量评分,以体重和kVp进行匹配,然后进行视觉分级特征(VGC)分析。结果:与固定剂量相比,基于体重的剂量降低了关键血管和器官增强对患者大小的依赖性。结论:通过在腹部CT中使用基于体重的ICM体积剂量,可以实现所有患者尺寸的一致的HU增强,尽管这并不一定转化为一致的主观图像质量。我们的研究结果表明,体重较轻的患者可能受益于更大的增强,以达到与体重较大的患者相同的主观图像质量,强调需要进一步优化ICM剂量策略,而不是标准的基于体重的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Medical Radiation Sciences
Journal of Medical Radiation Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.20
自引率
4.80%
发文量
69
审稿时长
8 weeks
期刊介绍: Journal of Medical Radiation Sciences (JMRS) is an international and multidisciplinary peer-reviewed journal that accepts manuscripts related to medical imaging / diagnostic radiography, radiation therapy, nuclear medicine, medical ultrasound / sonography, and the complementary disciplines of medical physics, radiology, radiation oncology, nursing, psychology and sociology. Manuscripts may take the form of: original articles, review articles, commentary articles, technical evaluations, case series and case studies. JMRS promotes excellence in international medical radiation science by the publication of contemporary and advanced research that encourages the adoption of the best clinical, scientific and educational practices in international communities. JMRS is the official professional journal of the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) and the New Zealand Institute of Medical Radiation Technology (NZIMRT).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书