The Effect of the Gutta Condensor on Powder-Liquid and Ready-to-Use Hydraulic Sealers.

Q2 Dentistry
Journal of Clinical and Experimental Dentistry Pub Date : 2026-06-29 eCollection Date: 2026-06-01 DOI:10.4317/jced.63891
Gabriel da Siqueira Felske, Gabriel Barcelos Só, Carolina Horn Troian Michel, Ricardo Abreu da Rosa, Marco Antônio Húngaro Duarte, Jefferson Ricardo Pereira, Marcus Vinicius Reis Só
{"title":"The Effect of the Gutta Condensor on Powder-Liquid and Ready-to-Use Hydraulic Sealers.","authors":"Gabriel da Siqueira Felske, Gabriel Barcelos Só, Carolina Horn Troian Michel, Ricardo Abreu da Rosa, Marco Antônio Húngaro Duarte, Jefferson Ricardo Pereira, Marcus Vinicius Reis Só","doi":"10.4317/jced.63891","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this study was to evaluate the increase in internal and external temperature of bovine tooth roots by driving the Gutta Condensor at two different speeds, as well as whether the sealers activation can cause alterations in the chemical structure of Bio-C Sealer and Cimmo HP, through Raman spectroscopy.</p><p><strong>Materials and methods: </strong>To assess the variation in root temperature, 60 bovine teeth were used. They were sectioned to standardize the samples to a length of 12mm, and their canals were prepared using VDW R50. After preparation, the roots were distributed into 12 groups, based on sealer type, use or non-use of gutta-percha, and Gutta Condensor speed. During root canal filling, internal and external temperatures of the roots were measured in all groups. To access the chemical structure, Raman spectroscopy was performed on both thermally activated and non-activated sealer samples (n=2).</p><p><strong>Results: </strong>It was demonstrated that both the sealer and the gutta-percha influenced the increase in internal and external root temperature. In intragroup comparisons, differences were observed between the speed of the Condensor and the control samples (P &lt; 0.05). Raman spectroscopy showed that both control and activated samples have the same chemical structure.</p><p><strong>Conclusions: </strong>This study concluded that the Gutta Condensor increases both internal and external temperatures to a non-critical point but does not affect the chemical structure of the sealer.</p>","PeriodicalId":15376,"journal":{"name":"Journal of Clinical and Experimental Dentistry","volume":"18 7","pages":"e865-e871"},"PeriodicalIF":0.0000,"publicationDate":"2026-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13386450/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical and Experimental Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4317/jced.63891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The purpose of this study was to evaluate the increase in internal and external temperature of bovine tooth roots by driving the Gutta Condensor at two different speeds, as well as whether the sealers activation can cause alterations in the chemical structure of Bio-C Sealer and Cimmo HP, through Raman spectroscopy.

Materials and methods: To assess the variation in root temperature, 60 bovine teeth were used. They were sectioned to standardize the samples to a length of 12mm, and their canals were prepared using VDW R50. After preparation, the roots were distributed into 12 groups, based on sealer type, use or non-use of gutta-percha, and Gutta Condensor speed. During root canal filling, internal and external temperatures of the roots were measured in all groups. To access the chemical structure, Raman spectroscopy was performed on both thermally activated and non-activated sealer samples (n=2).

Results: It was demonstrated that both the sealer and the gutta-percha influenced the increase in internal and external root temperature. In intragroup comparisons, differences were observed between the speed of the Condensor and the control samples (P < 0.05). Raman spectroscopy showed that both control and activated samples have the same chemical structure.

Conclusions: This study concluded that the Gutta Condensor increases both internal and external temperatures to a non-critical point but does not affect the chemical structure of the sealer.

Gutta冷凝器对粉末-液体和即用型液压密封器的影响。
背景:本研究的目的是通过拉曼光谱研究两种不同速度驱动Gutta冷凝器对牛牙根内外温度的升高,以及密封剂的激活是否会导致Bio-C密封剂和Cimmo HP的化学结构改变。材料与方法:采用60颗牛牙进行牙根温度变化的研究。切片使样品标准化至12mm长,用VDW R50制备管。制备后,根据封口剂类型、使用或不使用杜仲胶、杜仲胶速度将根分成12组。在根管充填过程中,测量各组根内、外温度。为了获得化学结构,对热活化和非活化密封剂样品(n=2)进行了拉曼光谱分析。结果:封口剂和杜仲胶对根内外温度的升高均有影响。在组内比较中,观察到冷凝器的速度与对照样品之间的差异(P < 0.05)。拉曼光谱分析表明,对照样品和活化样品具有相同的化学结构。结论:本研究得出结论,Gutta冷凝器将内部和外部温度提高到非临界点,但不影响密封剂的化学结构。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.70
自引率
0.00%
发文量
118
期刊介绍: Indexed in PUBMED, PubMed Central® (PMC) since 2012 and SCOPUSJournal of Clinical and Experimental Dentistry is an Open Access (free access on-line) - http://www.medicinaoral.com/odo/indice.htm. The aim of the Journal of Clinical and Experimental Dentistry is: - Periodontology - Community and Preventive Dentistry - Esthetic Dentistry - Biomaterials and Bioengineering in Dentistry - Operative Dentistry and Endodontics - Prosthetic Dentistry - Orthodontics - Oral Medicine and Pathology - Odontostomatology for the disabled or special patients - Oral Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书