Dynamic response of buried pipeline under the sliding instability of slopes in cold regions

IF 5 Q2 ENERGY & FUELS
Qiaozhen Li, Chao Wang, Chao Sun, Min Luo, Hao Wang, Haoming Liu
{"title":"Dynamic response of buried pipeline under the sliding instability of slopes in cold regions","authors":"Qiaozhen Li,&nbsp;Chao Wang,&nbsp;Chao Sun,&nbsp;Min Luo,&nbsp;Hao Wang,&nbsp;Haoming Liu","doi":"10.1016/j.jpse.2025.100344","DOIUrl":null,"url":null,"abstract":"<div><div>In order to study the dynamic response behavior of buried pipelines under the instability and sliding of slopes in cold regions, the buried pipelines in cold regions are taken as the research object. Considering the characteristics of large deformation and collapse of unstable soil, the material nonlinear characteristics of pipeline and foundation soil, and the contact nonlinear characteristics among pipeline, unstable slope and foundation soil, the nonlinear dynamic model of buried pipeline under slope instability is established by SPH-FEM (smoothed particle hydrodynamics-finite element method) method. Compared with the literature results, the maximum error is 0.67%, which verifies the rationality of the model and algorithm. Then, pipeline’s dynamic response with different influencing factors are studied. The results show that: The residual stress of pipeline decreases with the increase of pipeline position, with the decrease of diameter-to-thickness ratio of pipeline, and increases first and then decreases with the increase of freezing depth of foundation soil, with the variation amplitude of residual stress of 12.72%, 23.1% and 14.56% respectively. The pipeline displacement varies with different influencing factors, the maximum variation in the freezing depth of foundation soil can reach 22.6 mm, while in the diameter-to-thickness ratio and pipeline position can reach 6.9 mm and 5.4 mm respectively. The degree of local dent of the pipeline is most pronounced at the peak time,when the freezing depth of the foundation soil is 0 m, the local dent depth can reach 4.92% of the pipeline’s outer diameter. Relevant research methods are expected to provide guidance for the integrity management of slope pipeline engineering in cold regions.</div></div>","PeriodicalId":100824,"journal":{"name":"Journal of Pipeline Science and Engineering","volume":"6 4","pages":"Article 100344"},"PeriodicalIF":5.0000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pipeline Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667143325000915","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

In order to study the dynamic response behavior of buried pipelines under the instability and sliding of slopes in cold regions, the buried pipelines in cold regions are taken as the research object. Considering the characteristics of large deformation and collapse of unstable soil, the material nonlinear characteristics of pipeline and foundation soil, and the contact nonlinear characteristics among pipeline, unstable slope and foundation soil, the nonlinear dynamic model of buried pipeline under slope instability is established by SPH-FEM (smoothed particle hydrodynamics-finite element method) method. Compared with the literature results, the maximum error is 0.67%, which verifies the rationality of the model and algorithm. Then, pipeline’s dynamic response with different influencing factors are studied. The results show that: The residual stress of pipeline decreases with the increase of pipeline position, with the decrease of diameter-to-thickness ratio of pipeline, and increases first and then decreases with the increase of freezing depth of foundation soil, with the variation amplitude of residual stress of 12.72%, 23.1% and 14.56% respectively. The pipeline displacement varies with different influencing factors, the maximum variation in the freezing depth of foundation soil can reach 22.6 mm, while in the diameter-to-thickness ratio and pipeline position can reach 6.9 mm and 5.4 mm respectively. The degree of local dent of the pipeline is most pronounced at the peak time,when the freezing depth of the foundation soil is 0 m, the local dent depth can reach 4.92% of the pipeline’s outer diameter. Relevant research methods are expected to provide guidance for the integrity management of slope pipeline engineering in cold regions.
寒区边坡滑动失稳条件下埋地管线的动力响应
为了研究寒区埋地管道在边坡失稳和滑动作用下的动力响应行为,以寒区埋地管道为研究对象。考虑失稳土的大变形和崩塌特性、管道与地基土的材料非线性特性以及管道与失稳边坡和地基土之间的接触非线性特性,采用SPH-FEM(光滑颗粒水动力-有限元法)方法建立了边坡失稳下埋地管道的非线性动力模型。与文献结果比较,最大误差为0.67%,验证了模型和算法的合理性。然后,研究了不同影响因素下管道的动力响应。结果表明:管道残余应力随管道位置的增加、管道径厚比的减小而减小,随地基土冻结深度的增加先增大后减小,残余应力变化幅度分别为12.72%、23.1%和14.56%;管道位移随影响因素的不同而变化,地基土冻结深度变化最大可达22.6 mm,径厚比和管道位置变化最大可达6.9 mm和5.4 mm。管道局部凹陷程度在峰值时最为明显,当地基土冻结深度为0 m时,局部凹陷深度可达管道外径的4.92%。相关研究方法有望为寒区边坡管道工程完整性管理提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书