{"title":"Optimising spherical periacetabular osteotomy: a strategy to minimise leg shortening.","authors":"Toru Nishiwaki, Hisatoshi Ishikura, Yuji Masuyama, Sho Fujita","doi":"10.1177/11207000261458622","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Spherical periacetabular osteotomy (SPO) preserves pelvic structures but can cause leg shortening due to the upward and outward shift of the centre of rotation. Modified preoperative planning aims to medially shift the acetabular fragment's highest point to reduce leg shortening. This study investigated the fixation state of the rotated bone fragment in SPO, its relationship with leg length, and strategies to prevent leg shortening.</p><p><strong>Methods: </strong>Between February 2019 and August 2023, 57 joints in 52 patients undergoing SPO were examined. The postoperative acetabular movement was classified as \"contact\" or \"non-contact\" based on whether the proximal osteotomy surfaces of the rotated and host bone made direct contact on postoperative computed tomography scans. Radiographic assessments included leg length, centre-edge (CE) angle, and acetabular roof obliquity (ARO), measured on standardised anteroposterior pelvic radiographs before and after surgery.</p><p><strong>Results: </strong>Average correction angles were 24° for CE and 23° for ARO, with an average leg length change of -1.3 mm (range -14.5-9.7 mm). Contact-type fixation minimised leg shortening, with an average change of 0.3 mm (range -4.7-9.7 mm), and demonstrated better ARO correction. In contrast, non-contact fixation resulted in greater leg shortening, with an average change of -6.1 mm (range -14.5-4.9 mm).</p><p><strong>Conclusions: </strong>Contact-type fixation effectively reduced leg shortening and stabilised bone fragments. Conversely, non-contact types allowed greater correction angles but led to increased leg shortening due to instability. Enhanced fixation methods are recommended for non-contact cases to maintain stability.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":" ","pages":"842-849"},"PeriodicalIF":1.3000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000261458622","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Spherical periacetabular osteotomy (SPO) preserves pelvic structures but can cause leg shortening due to the upward and outward shift of the centre of rotation. Modified preoperative planning aims to medially shift the acetabular fragment's highest point to reduce leg shortening. This study investigated the fixation state of the rotated bone fragment in SPO, its relationship with leg length, and strategies to prevent leg shortening.

Methods: Between February 2019 and August 2023, 57 joints in 52 patients undergoing SPO were examined. The postoperative acetabular movement was classified as "contact" or "non-contact" based on whether the proximal osteotomy surfaces of the rotated and host bone made direct contact on postoperative computed tomography scans. Radiographic assessments included leg length, centre-edge (CE) angle, and acetabular roof obliquity (ARO), measured on standardised anteroposterior pelvic radiographs before and after surgery.

Results: Average correction angles were 24° for CE and 23° for ARO, with an average leg length change of -1.3 mm (range -14.5-9.7 mm). Contact-type fixation minimised leg shortening, with an average change of 0.3 mm (range -4.7-9.7 mm), and demonstrated better ARO correction. In contrast, non-contact fixation resulted in greater leg shortening, with an average change of -6.1 mm (range -14.5-4.9 mm).

Conclusions: Contact-type fixation effectively reduced leg shortening and stabilised bone fragments. Conversely, non-contact types allowed greater correction angles but led to increased leg shortening due to instability. Enhanced fixation methods are recommended for non-contact cases to maintain stability.

优化球形髋臼周围截骨术:最小化腿缩短的策略。
背景:球形髋臼周围截骨术(SPO)保留了骨盆结构,但由于旋转中心向上和向外移动,可能导致腿缩短。改良的术前计划旨在向内侧移动髋臼碎片的最高点,以减少腿短。本研究探讨了SPO中旋转骨碎片的固定状态,其与腿长的关系,以及防止腿变短的策略。方法:2019年2月至2023年8月,对52例SPO患者的57个关节进行检查。术后髋臼运动分为“接触”和“非接触”,基于术后计算机断层扫描中旋转骨的近端截骨面与宿主骨是否直接接触。放射学评估包括术前和术后标准化骨盆正位x线片测量的腿长、中心边缘(CE)角和髋臼顶倾角(ARO)。结果:CE的平均矫正角度为24°,ARO为23°,平均腿长变化为-1.3 mm(范围为-14.5-9.7 mm)。接触式固定使腿缩短最小化,平均变化0.3 mm(范围-4.7-9.7 mm),并表现出更好的ARO矫正。相比之下,非接触固定导致更大的腿缩短,平均变化-6.1 mm(范围-14.5-4.9 mm)。结论:接触式固定可有效减少腿短,稳定骨碎片。相反,非接触型允许更大的矫正角度,但由于不稳定导致腿缩短。对于非接触病例,建议加强固定方法以保持稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书