{"title":"Comments on “Experimental Evaluation of Relationship Between Radiofrequency Heating Near Implanted Conductive Devices, Scanner-Reported B1+rms, and Transmit Power”","authors":"Michael Steckner;Mark Conroy;Jonathan Edmonson;Tolga Goren","doi":"10.1109/JMW.2026.3666625","DOIUrl":null,"url":null,"abstract":"In the above article [1] regarding heating near implanted conductive medical devices during MRI, key experimental conditions regarding “RF shimming” parameters are not identified. Therefore, the exact mechanism causing the spread in heating cannot be reliably identified. The likely mechanism is suggested here, and it is noted that the spread in heating results is expected nor relevant, given standard implant testing procedures.","PeriodicalId":93296,"journal":{"name":"IEEE journal of microwaves","volume":"6 2","pages":"489-490"},"PeriodicalIF":4.5000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11437562","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE journal of microwaves","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11437562/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/17 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

In the above article [1] regarding heating near implanted conductive medical devices during MRI, key experimental conditions regarding “RF shimming” parameters are not identified. Therefore, the exact mechanism causing the spread in heating cannot be reliably identified. The likely mechanism is suggested here, and it is noted that the spread in heating results is expected nor relevant, given standard implant testing procedures.
对“植入导电装置附近射频加热与扫描仪报告B1+rms和发射功率关系的实验评估”的评论
在上述关于MRI期间植入的导电医疗设备附近加热的文章[1]中,没有确定有关“射频振荡”参数的关键实验条件。因此,导致加热扩散的确切机制不能可靠地确定。本文提出了可能的机制,并指出,考虑到标准的植入物测试程序,加热结果的传播是不相关的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.70
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书