{"title":"Design of Damping Coefficient in an Enhanced Droop-Based Grid Forming Control","authors":"Norbert R. Klaes;Benjamin Fellmann;Horst Schulte","doi":"10.1109/OJIA.2026.3707909","DOIUrl":null,"url":null,"abstract":"This article presents an enhanced droop-based grid-forming control method for inverter-based energy resources connected to the transmission grid. The main advantage of inverter control—its ability to control frequency and phase independently—over conventional synchronous machine behavior is emphasized. This additional degree of freedom is used to implement an intrinsically damped response to grid disturbances such as voltage steps, frequency deviations, and phase jumps. The proposed control is analyzed in the state-space for three representative operating scenarios: grid parallel operation, two weakly coupled power resources, and a two-area system with two resources per area. A design goal for the control gain is formulated and applied to the operating scenarios under consideration, using only characteristic per-unit quantities and time constants. It is shown that the damping coefficient at the boundary case of all real-valued poles mainly depends on the intrinsic parameters of the power resource, such as short-circuit impedance and filter time constants, and is fairly independent of other system parameters. Simulation results confirm the analytical design of the damping coefficient, using a two-area system as a benchmark case. In comparison to conventional power plants, the proposed grid-forming control with an optimized damping coefficient demonstrates a significantly improved damped response to grid events, such as load or generation changes or partial tie line tripping. Experimental results gained in a complex power system laboratory validate the well-damped behavior for typical grid events.","PeriodicalId":100629,"journal":{"name":"IEEE Open Journal of Industry Applications","volume":"7 ","pages":"658-673"},"PeriodicalIF":3.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11585951","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Industry Applications","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11585951/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

This article presents an enhanced droop-based grid-forming control method for inverter-based energy resources connected to the transmission grid. The main advantage of inverter control—its ability to control frequency and phase independently—over conventional synchronous machine behavior is emphasized. This additional degree of freedom is used to implement an intrinsically damped response to grid disturbances such as voltage steps, frequency deviations, and phase jumps. The proposed control is analyzed in the state-space for three representative operating scenarios: grid parallel operation, two weakly coupled power resources, and a two-area system with two resources per area. A design goal for the control gain is formulated and applied to the operating scenarios under consideration, using only characteristic per-unit quantities and time constants. It is shown that the damping coefficient at the boundary case of all real-valued poles mainly depends on the intrinsic parameters of the power resource, such as short-circuit impedance and filter time constants, and is fairly independent of other system parameters. Simulation results confirm the analytical design of the damping coefficient, using a two-area system as a benchmark case. In comparison to conventional power plants, the proposed grid-forming control with an optimized damping coefficient demonstrates a significantly improved damped response to grid events, such as load or generation changes or partial tie line tripping. Experimental results gained in a complex power system laboratory validate the well-damped behavior for typical grid events.
基于增强下垂的网格成形控制中阻尼系数的设计
本文提出了一种改进的基于下垂的并网控制方法,用于基于逆变器的能源并网。强调了逆变器控制的主要优势-其独立控制频率和相位的能力-优于传统的同步电机行为。这种额外的自由度用于实现对电网干扰(如电压阶跃、频率偏差和相位跳变)的固有阻尼响应。在状态空间中分析了三种典型运行场景:电网并行运行、两个弱耦合电力资源和每区域两个资源的两区系统。我们制定了控制增益的设计目标,并将其应用于所考虑的操作场景,仅使用单位特性量和时间常数。结果表明,在所有实值极点的边界情况下,阻尼系数主要取决于电源的固有参数,如短路阻抗和滤波器时间常数,而与系统的其他参数无关。仿真结果验证了以双区系统为基准的阻尼系数解析设计。与传统电厂相比,采用优化阻尼系数的电网形成控制对电网事件(如负荷或发电变化或部分联络线跳闸)的阻尼响应有显著改善。在一个复杂的电力系统实验室中获得的实验结果验证了典型电网事件的良好阻尼特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
13.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书