Toward a Chronic VNS Strategy for Obesity Treatment: Pilot Study on a PFA-Based Neural Interface in Diet-Induced Obese Rabbits

IF 3.9 3区 医学 Q2 ENGINEERING, BIOMEDICAL
Jisung Kim;Jane Chungyoon Kim;Kyoungyun Jeong;Jiseon Lee;Jiyeon Shin;Yie-Ri Yoo;Jaeun Yoo;Taekyung Lee;Joowon Lee;Gregg J. Suaning;Jong-Mo Seo;Changhoon Baek;Hyuk-Joon Lee
{"title":"Toward a Chronic VNS Strategy for Obesity Treatment: Pilot Study on a PFA-Based Neural Interface in Diet-Induced Obese Rabbits","authors":"Jisung Kim;Jane Chungyoon Kim;Kyoungyun Jeong;Jiseon Lee;Jiyeon Shin;Yie-Ri Yoo;Jaeun Yoo;Taekyung Lee;Joowon Lee;Gregg J. Suaning;Jong-Mo Seo;Changhoon Baek;Hyuk-Joon Lee","doi":"10.1109/JTEHM.2026.3708112","DOIUrl":null,"url":null,"abstract":"Subdiaphragmatic vagus nerve stimulation (VNS) is being explored as a device-based option for obesity, but translation is limited by the lack of standardized implantation workflows and cuff electrodes that remain stable at the cuff–nerve interface in a moist in vivo environment. Here, we aimed to establish a bench-to–in vivo feasibility platform that integrates a microfabrication-compatible perfluoroalkoxy alkane (PFA) film cuff with a reproducible rabbit surgical procedure and sham-controlled evaluation. The cuff electrode was fabricated using MEMS-based processes and characterized on the bench (impedance/charge metrics), then implanted on the subdiaphragmatic vagus nerve in diet-induced obese rabbits assigned to sham or intermittent VNS at graded current levels (total n = 8; n = 2/group). Body weight was tracked as an exploratory outcome under variable delivered exposure. During the stimulation window, weight trajectories showed heterogeneous, non-monotonic patterns across current levels, with partial rebound after stimulation cessation. Gross inspection and hematoxylin and eosin (H&E) histology indicated preserved fascicular organization with a thin peri-neural fibrotic capsule, assessed qualitatively in this pilot cohort. Overall, these results support feasibility of reproducible subdiaphragmatic implantation and cuff–nerve interface operation and motivate powered studies with exposure-matched delivery logging and expanded metabolic and longitudinal endpoints. Clinical and Impact: This work de-risks translation of subdiaphragmatic VNS by combining a scalable PFA-based cuff electrode with a reproducible intermediate-sized animal implantation workflow and conservative charge-density operation. The platform enables the next step: powered, controlled studies that optimize dosing and add metabolic and longitudinal interface endpoints relevant to implantable obesity neuromodulation.","PeriodicalId":54255,"journal":{"name":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","volume":"14 ","pages":"309-319"},"PeriodicalIF":3.9000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11586062","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Translational Engineering in Health and Medicine-Jtehm","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11586062/","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Subdiaphragmatic vagus nerve stimulation (VNS) is being explored as a device-based option for obesity, but translation is limited by the lack of standardized implantation workflows and cuff electrodes that remain stable at the cuff–nerve interface in a moist in vivo environment. Here, we aimed to establish a bench-to–in vivo feasibility platform that integrates a microfabrication-compatible perfluoroalkoxy alkane (PFA) film cuff with a reproducible rabbit surgical procedure and sham-controlled evaluation. The cuff electrode was fabricated using MEMS-based processes and characterized on the bench (impedance/charge metrics), then implanted on the subdiaphragmatic vagus nerve in diet-induced obese rabbits assigned to sham or intermittent VNS at graded current levels (total n = 8; n = 2/group). Body weight was tracked as an exploratory outcome under variable delivered exposure. During the stimulation window, weight trajectories showed heterogeneous, non-monotonic patterns across current levels, with partial rebound after stimulation cessation. Gross inspection and hematoxylin and eosin (H&E) histology indicated preserved fascicular organization with a thin peri-neural fibrotic capsule, assessed qualitatively in this pilot cohort. Overall, these results support feasibility of reproducible subdiaphragmatic implantation and cuff–nerve interface operation and motivate powered studies with exposure-matched delivery logging and expanded metabolic and longitudinal endpoints. Clinical and Impact: This work de-risks translation of subdiaphragmatic VNS by combining a scalable PFA-based cuff electrode with a reproducible intermediate-sized animal implantation workflow and conservative charge-density operation. The platform enables the next step: powered, controlled studies that optimize dosing and add metabolic and longitudinal interface endpoints relevant to implantable obesity neuromodulation.
慢性VNS治疗肥胖的策略:饮食诱导肥胖家兔pfa神经界面的初步研究
膈下迷走神经刺激(VNS)作为一种基于设备的肥胖治疗选择正在被探索,但由于缺乏标准化的植入工作流程和在潮湿的体内环境中在袖带-神经界面保持稳定的袖带电极,其转化受到限制。在这里,我们的目标是建立一个从实验台到体内的可行性平台,该平台将微加工兼容的全氟烷氧基烷烃(PFA)膜袖带与可重复的兔子手术过程和假对照评估相结合。采用基于mems的工艺制作cuff电极,并在实验台上进行表征(阻抗/电荷指标),然后以分级电流水平将其植入饮食诱导的肥胖兔子的膈下迷走神经上(n = 8; n = 2/组)。体重被跟踪作为一个探索性结果在可变传递暴露。在刺激窗口期间,体重轨迹在当前水平上表现出异质性,非单调模式,在刺激停止后出现部分反弹。大体检查和苏木精和伊红(H&E)组织学显示保存的束状组织和薄的神经周围纤维化胶囊,在这个试点队列中进行了定性评估。总的来说,这些结果支持可重复的膈下植入和袖神经界面手术的可行性,并激发了与暴露匹配的输送记录和扩展的代谢和纵向终点的有力研究。临床和影响:本研究通过结合可扩展的pfa基袖带电极、可重复的中等大小动物植入工作流程和保守的电荷密度操作,降低了膈下VNS转译的风险。该平台支持下一步:优化剂量并添加与植入式肥胖神经调节相关的代谢和纵向接口端点的动力控制研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.40
自引率
2.90%
发文量
65
审稿时长
27 weeks
期刊介绍: The IEEE Journal of Translational Engineering in Health and Medicine is an open access product that bridges the engineering and clinical worlds, focusing on detailed descriptions of advanced technical solutions to a clinical need along with clinical results and healthcare relevance. The journal provides a platform for state-of-the-art technology directions in the interdisciplinary field of biomedical engineering, embracing engineering, life sciences and medicine. A unique aspect of the journal is its ability to foster a collaboration between physicians and engineers for presenting broad and compelling real world technological and engineering solutions that can be implemented in the interest of improving quality of patient care and treatment outcomes, thereby reducing costs and improving efficiency. The journal provides an active forum for clinical research and relevant state-of the-art technology for members of all the IEEE societies that have an interest in biomedical engineering as well as reaching out directly to physicians and the medical community through the American Medical Association (AMA) and other clinical societies. The scope of the journal includes, but is not limited, to topics on: Medical devices, healthcare delivery systems, global healthcare initiatives, and ICT based services; Technological relevance to healthcare cost reduction; Technology affecting healthcare management, decision-making, and policy; Advanced technical work that is applied to solving specific clinical needs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书