Saritha Lalitha Ravindran, Dipti Jadhav, Sandeep Sangle, Pankaj Kumar Jain, Andrew Nicolaides, Luca Saba, Ajith Abraham, Jasjit S Suri
{"title":"PatchGAN-guided semi-supervised U-Net for carotid plaque segmentation in ultrasound under limited annotation conditions.","authors":"Saritha Lalitha Ravindran, Dipti Jadhav, Sandeep Sangle, Pankaj Kumar Jain, Andrew Nicolaides, Luca Saba, Ajith Abraham, Jasjit S Suri","doi":"10.1186/s12880-026-02574-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Artificial intelligence models are increasingly used for stroke risk evaluation and clinical decision-making. However, the scarcity of expert masks, low contrast, and noise in ultrasound images affect segmentation performance.</p><p><strong>Methods: </strong>Our study innovatively integrated an adversarial PatchGAN discriminator into a batch-normalized semi-supervised U-Net generator to enhance carotid plaque segmentation in ultrasound images with limited expert annotation. The discriminator provides patch-level localized feedback to enhance boundary delineation and structural consistency of the predicted masks. The model was trained using a hybrid loss function and self-training strategy. The performance of our framework was compared with a fine-tuned semi-supervised U-Net model. Both frameworks were trained under identical experimental settings using 30% of the labeled data; the remaining unlabeled images were utilized to generate pseudo-labels for data augmentation. A confidence threshold of 0.7 was applied to filter unreliable predictions.</p><p><strong>Results: </strong>We conducted experiments on a dataset of 970 internal carotid artery ultrasound images from the Imperial College of London, UK. The experimental results showed that the proposed framework achieved a Dice coefficient of 86.12 and a Jaccard index of 75.66, outperforming the baseline U-Net (84.22 and 73.12, respectively).</p><p><strong>Conclusions: </strong>The integration of patch-level adversarial feedback into a semi-supervised framework enhanced the segmentation accuracy and improved the reliability of pseudo-labels under limited supervision. The results were comparable to those of state-of-the-art deep learning models, which require a large pool of labeled data.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":" ","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2026-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13656442/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-026-02574-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Artificial intelligence models are increasingly used for stroke risk evaluation and clinical decision-making. However, the scarcity of expert masks, low contrast, and noise in ultrasound images affect segmentation performance.
Methods: Our study innovatively integrated an adversarial PatchGAN discriminator into a batch-normalized semi-supervised U-Net generator to enhance carotid plaque segmentation in ultrasound images with limited expert annotation. The discriminator provides patch-level localized feedback to enhance boundary delineation and structural consistency of the predicted masks. The model was trained using a hybrid loss function and self-training strategy. The performance of our framework was compared with a fine-tuned semi-supervised U-Net model. Both frameworks were trained under identical experimental settings using 30% of the labeled data; the remaining unlabeled images were utilized to generate pseudo-labels for data augmentation. A confidence threshold of 0.7 was applied to filter unreliable predictions.
Results: We conducted experiments on a dataset of 970 internal carotid artery ultrasound images from the Imperial College of London, UK. The experimental results showed that the proposed framework achieved a Dice coefficient of 86.12 and a Jaccard index of 75.66, outperforming the baseline U-Net (84.22 and 73.12, respectively).
Conclusions: The integration of patch-level adversarial feedback into a semi-supervised framework enhanced the segmentation accuracy and improved the reliability of pseudo-labels under limited supervision. The results were comparable to those of state-of-the-art deep learning models, which require a large pool of labeled data.
期刊介绍:
BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.