Fabrication and evaluation of high-density concrete shields using lead and polypropylene fibres for head computed tomography.

IF 0.8 4区 环境科学与生态学 Q4 ENVIRONMENTAL SCIENCES
Mohammed K Saeed, Yousif Abdallah, Ibrahim Yahya A Hakeem
{"title":"Fabrication and evaluation of high-density concrete shields using lead and polypropylene fibres for head computed tomography.","authors":"Mohammed K Saeed, Yousif Abdallah, Ibrahim Yahya A Hakeem","doi":"10.1093/rpd/ncag072","DOIUrl":null,"url":null,"abstract":"<p><p>This study developed and evaluated novel high-density concrete shields (HDCS) to protect the radiosensitive ocular lens during head computed tomography (CT). Five formulations with varying polypropylene and lead fibres were tested using anthropomorphic phantoms and clinical patients (n = 35). The lead-free M1 formulation (9.2 kg/m3 polypropylene) was optimal, achieving ~35% reduction in patient ocular lens dose across both CT acquisition protocols. Quantitative American College of Radiology phantom tests confirmed maintained CT number accuracy, uniformity, and spatial resolution. Qualitative radiologist assessment found minimal anterior artefacts that did not affect diagnostic interpretation of central or posterior brain structures. The M1 HDCS is a viable, potentially cost-effective shielding alternative, ideal for routine head CT where orbital detail is not the primary focus.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":"1365-1376"},"PeriodicalIF":0.8000,"publicationDate":"2026-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncag072","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This study developed and evaluated novel high-density concrete shields (HDCS) to protect the radiosensitive ocular lens during head computed tomography (CT). Five formulations with varying polypropylene and lead fibres were tested using anthropomorphic phantoms and clinical patients (n = 35). The lead-free M1 formulation (9.2 kg/m3 polypropylene) was optimal, achieving ~35% reduction in patient ocular lens dose across both CT acquisition protocols. Quantitative American College of Radiology phantom tests confirmed maintained CT number accuracy, uniformity, and spatial resolution. Qualitative radiologist assessment found minimal anterior artefacts that did not affect diagnostic interpretation of central or posterior brain structures. The M1 HDCS is a viable, potentially cost-effective shielding alternative, ideal for routine head CT where orbital detail is not the primary focus.

头部计算机断层扫描用铅和聚丙烯纤维高密度混凝土屏蔽的制造和评价。
本研究开发并评估了新型高密度混凝土护罩(HDCS)在头部计算机断层扫描(CT)中保护放射敏感晶状体的效果。采用拟人模型和临床患者(n = 35)对五种不同聚丙烯和铅纤维的配方进行了测试。无铅M1配方(9.2 kg/m3聚丙烯)是最佳的,在两种CT采集方案中,患者的晶体剂量减少了约35%。定量美国放射学院幻象测试证实保持了CT数字的准确性、均匀性和空间分辨率。定性放射科医生的评估发现,少量的前假影不影响对中央或后脑结构的诊断解释。M1 HDCS是一种可行的、具有潜在成本效益的屏蔽替代方案,是常规头部CT的理想选择,因为轨道细节不是主要关注的焦点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation protection dosimetry
Radiation protection dosimetry 环境科学-公共卫生、环境卫生与职业卫生
CiteScore
1.40
自引率
10.00%
发文量
223
审稿时长
6-12 weeks
期刊介绍: Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书