Mohammed K Saeed, Yousif Abdallah, Ibrahim Yahya A Hakeem
{"title":"Fabrication and evaluation of high-density concrete shields using lead and polypropylene fibres for head computed tomography.","authors":"Mohammed K Saeed, Yousif Abdallah, Ibrahim Yahya A Hakeem","doi":"10.1093/rpd/ncag072","DOIUrl":null,"url":null,"abstract":"<p><p>This study developed and evaluated novel high-density concrete shields (HDCS) to protect the radiosensitive ocular lens during head computed tomography (CT). Five formulations with varying polypropylene and lead fibres were tested using anthropomorphic phantoms and clinical patients (n = 35). The lead-free M1 formulation (9.2 kg/m3 polypropylene) was optimal, achieving ~35% reduction in patient ocular lens dose across both CT acquisition protocols. Quantitative American College of Radiology phantom tests confirmed maintained CT number accuracy, uniformity, and spatial resolution. Qualitative radiologist assessment found minimal anterior artefacts that did not affect diagnostic interpretation of central or posterior brain structures. The M1 HDCS is a viable, potentially cost-effective shielding alternative, ideal for routine head CT where orbital detail is not the primary focus.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":"1365-1376"},"PeriodicalIF":0.8000,"publicationDate":"2026-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncag072","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
This study developed and evaluated novel high-density concrete shields (HDCS) to protect the radiosensitive ocular lens during head computed tomography (CT). Five formulations with varying polypropylene and lead fibres were tested using anthropomorphic phantoms and clinical patients (n = 35). The lead-free M1 formulation (9.2 kg/m3 polypropylene) was optimal, achieving ~35% reduction in patient ocular lens dose across both CT acquisition protocols. Quantitative American College of Radiology phantom tests confirmed maintained CT number accuracy, uniformity, and spatial resolution. Qualitative radiologist assessment found minimal anterior artefacts that did not affect diagnostic interpretation of central or posterior brain structures. The M1 HDCS is a viable, potentially cost-effective shielding alternative, ideal for routine head CT where orbital detail is not the primary focus.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.