Sensor-integrated dual-clad fiber probe for OCT-guided retinal endolaser photocoagulation.

IF 3.3 3区 医学 Q2 BIOCHEMICAL RESEARCH METHODS
Journal of Biomedical Optics Pub Date : 2026-07-01 Epub Date: 2026-07-15 DOI:10.1117/1.JBO.31.7.077001
Dongyue Wu, Florian Lux, Max Mai Tobon, Holger Muenz, Soeren Schmidt, Eleonora Tagliabue, Philipp Matten, Çağlar Ataman
{"title":"Sensor-integrated dual-clad fiber probe for OCT-guided retinal endolaser photocoagulation.","authors":"Dongyue Wu, Florian Lux, Max Mai Tobon, Holger Muenz, Soeren Schmidt, Eleonora Tagliabue, Philipp Matten, Çağlar Ataman","doi":"10.1117/1.JBO.31.7.077001","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Retinal endolaser photocoagulation is a widely performed vitreoretinal procedure but currently lacks real-time intraoperative feedback on treatment outcomes. Integrating optical coherence tomography (OCT) directly into the endolaser probe enables co-localized, intraoperative sensing of tissue response during laser delivery, offering the potential to significantly enhance surgical safety and efficacy.</p><p><strong>Aim: </strong>The aim of the study is to design, fabricate, and demonstrate a fiber-optic smart instrument with a 3D nano-printed microlens and instrument-integrated OCT sensing that enables co-localized, concurrent surgical laser delivery and tomographic sensing of tissue alterations during REPC.</p><p><strong>Approach: </strong>A dual-clad fiber was used to co-axially deliver surgical and OCT beams through the outer multi-mode and inner single-mode cores. A 3D nano-printed aspherical microlens ( <math><mrow><mn>300</mn> <mtext>  </mtext> <mi>μ</mi> <mi>m</mi></mrow> </math> diameter) at the fiber tip optimized beam shaping for both lasers in the intravitreal cavity. The optical performance of the 23G instrument-integrated OCT (iiOCT) probe was characterized, and <i>ex vivo</i> validation experiments were conducted on porcine eyes.</p><p><strong>Results: </strong>Optical performance assessments demonstrated close alignment between measured and simulated beam profiles, with an OCT spot size of <math><mrow><mn>37.9</mn> <mtext>  </mtext> <mi>μ</mi> <mi>m</mi></mrow> </math> at best focus and a surgical laser beam divergence half-angle of 6.0 deg. The probe demonstrated stable power transmission with a mean deviation of 0.35% across repeated pulses. <i>Ex vivo</i> experiments confirmed co-localized, concurrent surgical laser delivery and OCT sensing of retinal tissue alterations.</p><p><strong>Conclusions: </strong>The miniaturized iiOCT endolaser probe combines surgical laser delivery with OCT sensing, achieving adequate performance for the targeted clinical application. This sensor-integrated instrument has the potential to enable intraocular, intraoperative, and quantitative assessment of treatment outcomes. It could support feedback-driven, robotic endolaser photocoagulation, enhancing the safety and efficacy of retinal endolaser surgery.</p>","PeriodicalId":15264,"journal":{"name":"Journal of Biomedical Optics","volume":"31 7","pages":"077001"},"PeriodicalIF":3.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13371110/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomedical Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1117/1.JBO.31.7.077001","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Retinal endolaser photocoagulation is a widely performed vitreoretinal procedure but currently lacks real-time intraoperative feedback on treatment outcomes. Integrating optical coherence tomography (OCT) directly into the endolaser probe enables co-localized, intraoperative sensing of tissue response during laser delivery, offering the potential to significantly enhance surgical safety and efficacy.

Aim: The aim of the study is to design, fabricate, and demonstrate a fiber-optic smart instrument with a 3D nano-printed microlens and instrument-integrated OCT sensing that enables co-localized, concurrent surgical laser delivery and tomographic sensing of tissue alterations during REPC.

Approach: A dual-clad fiber was used to co-axially deliver surgical and OCT beams through the outer multi-mode and inner single-mode cores. A 3D nano-printed aspherical microlens ( 300    μ m diameter) at the fiber tip optimized beam shaping for both lasers in the intravitreal cavity. The optical performance of the 23G instrument-integrated OCT (iiOCT) probe was characterized, and ex vivo validation experiments were conducted on porcine eyes.

Results: Optical performance assessments demonstrated close alignment between measured and simulated beam profiles, with an OCT spot size of 37.9    μ m at best focus and a surgical laser beam divergence half-angle of 6.0 deg. The probe demonstrated stable power transmission with a mean deviation of 0.35% across repeated pulses. Ex vivo experiments confirmed co-localized, concurrent surgical laser delivery and OCT sensing of retinal tissue alterations.

Conclusions: The miniaturized iiOCT endolaser probe combines surgical laser delivery with OCT sensing, achieving adequate performance for the targeted clinical application. This sensor-integrated instrument has the potential to enable intraocular, intraoperative, and quantitative assessment of treatment outcomes. It could support feedback-driven, robotic endolaser photocoagulation, enhancing the safety and efficacy of retinal endolaser surgery.

集成传感器的双包层光纤探头用于oct引导视网膜内激光光凝。
意义:视网膜内激光光凝是一种广泛应用的玻璃体视网膜手术,但目前缺乏术中治疗结果的实时反馈。将光学相干断层扫描(OCT)直接集成到激光探针中,可以在激光传输过程中实现共定位、术中组织反应的感知,从而有可能显著提高手术的安全性和有效性。目的:该研究的目的是设计、制造和演示一种光纤智能仪器,该仪器具有3D纳米打印微透镜和仪器集成的OCT传感,可以在REPC期间实现共定位、并发手术激光传输和组织改变的层析传感。方法:采用双包层光纤通过外部多模芯和内部单模芯同轴传输手术和OCT光束。光纤尖端的3D纳米打印非球面微透镜(直径300 μ m)优化了玻璃体内腔内两种激光器的光束整形。对23G仪器集成OCT (iiOCT)探针的光学性能进行了表征,并在猪眼上进行了离体验证实验。结果:光学性能评估表明,测量和模拟光束轮廓紧密对准,最佳聚焦时OCT光斑尺寸为37.9 μ m,手术激光束发散半角为6.0°。探针具有稳定的功率传输,重复脉冲的平均偏差为0.35%。离体实验证实了视网膜组织改变的共定位、同步手术激光传递和OCT传感。结论:小型化的ioct内激光探头将手术激光输送与OCT传感相结合,具有良好的临床针对性。这种传感器集成的仪器有可能实现眼内、术中和治疗结果的定量评估。它可以支持反馈驱动的机器人激光光凝,提高视网膜激光手术的安全性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.40
自引率
5.70%
发文量
263
审稿时长
2 months
期刊介绍: The Journal of Biomedical Optics publishes peer-reviewed papers on the use of modern optical technology for improved health care and biomedical research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书