Adna Softić, Faruk Bećirović, Ilma Mujković, Renata Klasan, Lejla Mahmutović, Abas Sezer, Lejla Gurbeta Pokvić, Daria Ler, Ernesto Iadanza
{"title":"Automated comet assay analysis using YOLOv5-based deep learning.","authors":"Adna Softić, Faruk Bećirović, Ilma Mujković, Renata Klasan, Lejla Mahmutović, Abas Sezer, Lejla Gurbeta Pokvić, Daria Ler, Ernesto Iadanza","doi":"10.1177/09287329261466485","DOIUrl":null,"url":null,"abstract":"<p><p>BackgroundThe comet assay is a sensitive and widely used technique for assessing DNA damage at the single-cell level. Despite its advantages, traditional manual scoring methods remain time-consuming, subjective and limited in scalability, posing challenges for high-throughput and standardized analysis.ObjectiveThis study aims to develop and evaluate a deep learning-based system for automated comet assay image classification, addressing limitations of manual and semi-automated approaches while enhancing accuracy, reproducibility and processing efficiency.MethodA YOLOv5-based object detection model was trained on a dataset of 875 annotated comet assay images, curated through a three-step expert-reviewed process. Various hyperparameters and data augmentation techniques were optimized to improve performance. The dataset was split into training, validation and test sets, and model performance was evaluated using mAP, precision, recall and confusion matrix analysis.ResultsThe model achieved strong performance, with mAP@0.5 reaching 0.98 and recall exceeding 0.8. Detailed analyses revealed robust learning behavior and generalization capacity. Visual outputs, including precision-recall curves and class-wise confusion matrices, confirmed high classification accuracy, although overlapping comet structures and class imbalance posed challenges. The model demonstrated improved scalability and processing speed compared to traditional tools, supporting its integration into web-based applications.ConclusionThe proposed YOLOv5-based system offers a scalable and accurate solution for automating comet assay analysis. It significantly enhances throughput and reduces human error, supporting its application in genotoxicity testing, biomonitoring and molecular epidemiology. Future work will focus on handling overlapping structures, benchmarking against existing tools and optimizing deployment in real-world laboratory settings.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":"9287329261466485"},"PeriodicalIF":1.3000,"publicationDate":"2026-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09287329261466485","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
BackgroundThe comet assay is a sensitive and widely used technique for assessing DNA damage at the single-cell level. Despite its advantages, traditional manual scoring methods remain time-consuming, subjective and limited in scalability, posing challenges for high-throughput and standardized analysis.ObjectiveThis study aims to develop and evaluate a deep learning-based system for automated comet assay image classification, addressing limitations of manual and semi-automated approaches while enhancing accuracy, reproducibility and processing efficiency.MethodA YOLOv5-based object detection model was trained on a dataset of 875 annotated comet assay images, curated through a three-step expert-reviewed process. Various hyperparameters and data augmentation techniques were optimized to improve performance. The dataset was split into training, validation and test sets, and model performance was evaluated using mAP, precision, recall and confusion matrix analysis.ResultsThe model achieved strong performance, with mAP@0.5 reaching 0.98 and recall exceeding 0.8. Detailed analyses revealed robust learning behavior and generalization capacity. Visual outputs, including precision-recall curves and class-wise confusion matrices, confirmed high classification accuracy, although overlapping comet structures and class imbalance posed challenges. The model demonstrated improved scalability and processing speed compared to traditional tools, supporting its integration into web-based applications.ConclusionThe proposed YOLOv5-based system offers a scalable and accurate solution for automating comet assay analysis. It significantly enhances throughput and reduces human error, supporting its application in genotoxicity testing, biomonitoring and molecular epidemiology. Future work will focus on handling overlapping structures, benchmarking against existing tools and optimizing deployment in real-world laboratory settings.
期刊介绍:
Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered:
1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables.
2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words.
Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics.
4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors.
5.Letters to the Editors: Discussions or short statements (not indexed).