Accuracy and cut-off values of different acoustic measures in the sustained vowel task of Brazilian Portuguese speakers.

IF 0.9 Q4 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY
CoDAS Pub Date : 2026-07-03 eCollection Date: 2026-01-01 DOI:10.1590/2317-1782/e20250288pt
Amanda Feliciano, Mara Behlau, Jordana Balbinot, Samuel Ribeiro de Abreu, Vanessa Veis Ribeiro, Leonardo Wanderley Lopes
{"title":"Accuracy and cut-off values of different acoustic measures in the sustained vowel task of Brazilian Portuguese speakers.","authors":"Amanda Feliciano, Mara Behlau, Jordana Balbinot, Samuel Ribeiro de Abreu, Vanessa Veis Ribeiro, Leonardo Wanderley Lopes","doi":"10.1590/2317-1782/e20250288pt","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To define cut-off values for acoustic measures extracted from the sustained vowel [a] task to discriminate between the presence and absence of vocal disorders in Brazilian Portuguese speakers.</p><p><strong>Methods: </strong>The sample consisted of 376 participants, 288 female and 88 male, with a mean age of 41.20 ± 14.04 years. All individuals underwent a laryngological evaluation and a voice recording session, during which a sustained vowel [a] sample was collected. Subsequently both auditory-perceptual and acoustic analyses of the voice were performed. Among the participants 277 were classified as having a vocal disorder and 99 as having no vocal disorder. A total of 44 acoustic measures were extracted and analyzed using ROC curves to determine the cut-off value for each measure, along with their performance metrics (sensitivity, specificity and AUC).</p><p><strong>Results: </strong>Cut-off values were established for 23 of the 44 extracted acoustic measures. Six measures showed robust and clinically relevant performance in discriminating between voices with and without vocal disorders in Brazilian Portuguese speakers. The measures with AUC values greater than 0.70 and balanced sensitivity and specificity above 70% were: Amplitude Variability Index (AVI) (≤0,91), Glottal-to-noise excitation (GNE)2000Hz (>0,92), Spectral Noise Level (SNL)100-2600Hz (≤7,71), SNL100-3000Hz (≤3,38), SNL100-8000Hz (≤10,95) and SNL5100-8000Hz (≤-1,84).</p><p><strong>Conclusion: </strong>Six acoustic measures demonstrated satisfactory performance in identifying the presence of vocal disorders in Brazilian Portuguese speakers. Ten measures showed good performance for voice screening purposes and seven for diagnostic confirmation of vocal disorders.</p>","PeriodicalId":46547,"journal":{"name":"CoDAS","volume":"38 4","pages":"e20250288"},"PeriodicalIF":0.9000,"publicationDate":"2026-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13330937/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CoDAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2317-1782/e20250288pt","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To define cut-off values for acoustic measures extracted from the sustained vowel [a] task to discriminate between the presence and absence of vocal disorders in Brazilian Portuguese speakers.

Methods: The sample consisted of 376 participants, 288 female and 88 male, with a mean age of 41.20 ± 14.04 years. All individuals underwent a laryngological evaluation and a voice recording session, during which a sustained vowel [a] sample was collected. Subsequently both auditory-perceptual and acoustic analyses of the voice were performed. Among the participants 277 were classified as having a vocal disorder and 99 as having no vocal disorder. A total of 44 acoustic measures were extracted and analyzed using ROC curves to determine the cut-off value for each measure, along with their performance metrics (sensitivity, specificity and AUC).

Results: Cut-off values were established for 23 of the 44 extracted acoustic measures. Six measures showed robust and clinically relevant performance in discriminating between voices with and without vocal disorders in Brazilian Portuguese speakers. The measures with AUC values greater than 0.70 and balanced sensitivity and specificity above 70% were: Amplitude Variability Index (AVI) (≤0,91), Glottal-to-noise excitation (GNE)2000Hz (>0,92), Spectral Noise Level (SNL)100-2600Hz (≤7,71), SNL100-3000Hz (≤3,38), SNL100-8000Hz (≤10,95) and SNL5100-8000Hz (≤-1,84).

Conclusion: Six acoustic measures demonstrated satisfactory performance in identifying the presence of vocal disorders in Brazilian Portuguese speakers. Ten measures showed good performance for voice screening purposes and seven for diagnostic confirmation of vocal disorders.

巴西葡萄牙语使用者持续元音任务中不同声学测量的准确性和临界值。
目的:定义从持续元音[a]任务中提取的声学测量的临界值,以区分巴西葡萄牙语使用者是否存在发声障碍。方法:共376人,其中女性288人,男性88人,平均年龄41.20±14.04岁。所有人都接受了喉科评估和录音,在此期间收集了一个持续的元音[a]样本。随后,对声音进行了听觉感知和声学分析。在参与者中,277人被归类为有发声障碍,99人被归类为没有发声障碍。总共提取了44个声学测量值,并使用ROC曲线进行分析,以确定每个测量值的截止值,以及它们的性能指标(灵敏度、特异性和AUC)。结果:提取的44个声学测量值中有23个建立了截止值。六项测量显示了巴西葡萄牙语使用者在区分有和没有声音障碍的声音方面的稳健和临床相关的表现。AUC值大于0.70且平衡灵敏度和特异性均大于70%的测量指标为:振幅变异性指数(AVI)(≤0,91)、声门噪声激励(GNE)2000Hz(>0,92)、频谱噪声级(SNL)100-2600Hz(≤7,71)、SNL100-3000Hz(≤3,38)、SNL100-8000Hz(≤10,95)和SNL5100-8000Hz(≤-1,84)。结论:六种声学测量方法在识别巴西葡萄牙语使用者的发声障碍方面表现出令人满意的效果。10项指标在声音筛查方面表现良好,7项指标在声音障碍诊断方面表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CoDAS
CoDAS AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-
CiteScore
0.90
自引率
12.50%
发文量
103
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书