{"title":"Visualization of time-resolved scattered radiation distribution in a computed tomography room utilizing a semiconductor survey meter.","authors":"Masanao Kobayashi, Juria Suzuki, Yusei Nishihara, Tomonobu Haba, Shigeki Kobayashi","doi":"10.1093/rpd/ncag073","DOIUrl":null,"url":null,"abstract":"<p><p>In diagnostic computed tomography (CT), radiological technologists and assisting staff may need to remain inside the CT room during patient assistance. Understanding temporal changes in scattered radiation distribution is therefore important for reducing occupational exposure. Conventional measurements mainly provide instantaneous dose rates or accumulated doses and are less suited to intuitively capturing temporal changes during CT scanning. This study conducted a fundamental investigation of a visualization approach, defined as dynamic dose distribution (DDD), based on time-resolved air kerma measurements obtained with a semiconductor survey meter. Scattered radiation was measured during chest-to-pelvis helical CT scanning of an anthropomorphic phantom under fixed tube current and automatic exposure control conditions. DDD allowed temporal changes in scattered radiation distribution to be visually identified in relation to tube current modulation, patient table position, and measurement height. DDD may provide useful temporal information for considering staff positioning and reducing occupational exposure.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":" ","pages":"1354-1364"},"PeriodicalIF":0.8000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncag073","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
In diagnostic computed tomography (CT), radiological technologists and assisting staff may need to remain inside the CT room during patient assistance. Understanding temporal changes in scattered radiation distribution is therefore important for reducing occupational exposure. Conventional measurements mainly provide instantaneous dose rates or accumulated doses and are less suited to intuitively capturing temporal changes during CT scanning. This study conducted a fundamental investigation of a visualization approach, defined as dynamic dose distribution (DDD), based on time-resolved air kerma measurements obtained with a semiconductor survey meter. Scattered radiation was measured during chest-to-pelvis helical CT scanning of an anthropomorphic phantom under fixed tube current and automatic exposure control conditions. DDD allowed temporal changes in scattered radiation distribution to be visually identified in relation to tube current modulation, patient table position, and measurement height. DDD may provide useful temporal information for considering staff positioning and reducing occupational exposure.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.