Effect of build orientation on marginal and internal discrepancies of zirconia crowns fabricated by using digital light processing 3D printing: A clinical study

IF 5.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Prosthetic Dentistry Pub Date : 2026-10-01 Epub Date: 2026-07-14 DOI:10.1016/j.prosdent.2026.06.028
Ji-Min Cha DDS, KeunBaDa Son PhD, Yoon-Jeong Shin DDS, Gyu Ri Kim MS, So-Yeun Kim DDS, PhD, Kyu-Bok Lee DDS, PhD
{"title":"Effect of build orientation on marginal and internal discrepancies of zirconia crowns fabricated by using digital light processing 3D printing: A clinical study","authors":"Ji-Min Cha DDS,&nbsp;KeunBaDa Son PhD,&nbsp;Yoon-Jeong Shin DDS,&nbsp;Gyu Ri Kim MS,&nbsp;So-Yeun Kim DDS, PhD,&nbsp;Kyu-Bok Lee DDS, PhD","doi":"10.1016/j.prosdent.2026.06.028","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>Digital light processing (DLP) 3-dimensional (3D) printing enables the additive fabrication of monolithic zirconia crowns; however, the effect of build orientation on their marginal and internal discrepancies in vivo, relative to conventionally milled zirconia crowns, remains insufficiently characterized.</div></div><div>Digital light processing (DLP) 3-dimensional (3D) printing enables the additive fabrication of monolithic zirconia crowns; however, the effect of build orientation on their marginal and internal discrepancies in vivo, relative to conventionally milled zirconia crowns, remains insufficiently characterized.</div><div><h3>Purpose</h3><div>The purpose of this clinical study was to compare the marginal and internal discrepancies of zirconia crowns fabricated by conventional milling and by DLP 3D printing and to evaluate the influence of build orientation (0, 45, and 90 degrees) on the fit of DLP- printed crowns.</div></div><div>The purpose of this clinical study was to compare the marginal and internal discrepancies of zirconia crowns fabricated by conventional milling and by DLP 3D printing and to evaluate the influence of build orientation (0, 45, and 90 degrees) on the fit of DLP- printed crowns.</div><div><h3>Material and methods</h3><div>Ten participants requiring a single posterior zirconia crown in the maxilla or mandible were enrolled. For each participant, 4 crowns with identical designs were fabricated: 1 milled crown (Ceramill Motion 2; Amann Girrbach AG) and 3 DLP-printed crowns (TD 6; 3D Controls Co Ltd) at build orientations of 0, 45, and 90 degrees. 4Y PSZ zirconia blocks (Ceramill Zolid FX; Amann Girrbach AG) and a 3Y TZP zirconia slurry (3DCera; 3D Controls Co Ltd) were used. The silicone replica technique (Fit Checker; GC Corp) was used to measure the absolute marginal discrepancy (AMD), marginal gap (MG), and internal discrepancies at the chamfer, axial, line angle, and occlusal regions. Replica thicknesses were quantified under a digital microscope. Data were analyzed with a 1-way repeated measures analysis of variance, with fabrication condition treated as a within-subject factor. Post hoc pairwise comparisons were adjusted with the Holm procedure, and partial η<sup>2</sup> values were calculated to quantify effect size (α=.05).</div></div><div>Ten participants requiring a single posterior zirconia crown in the maxilla or mandible were enrolled. For each participant, 4 crowns with identical designs were fabricated: 1 milled crown (Ceramill Motion 2; Amann Girrbach AG) and 3 DLP-printed crowns (TD 6; 3D Controls Co Ltd) at build orientations of 0, 45, and 90 degrees. 4Y PSZ zirconia blocks (Ceramill Zolid FX; Amann Girrbach AG) and a 3Y TZP zirconia slurry (3DCera; 3D Controls Co Ltd) were used. The silicone replica technique (Fit Checker; GC Corp) was used to measure the absolute marginal discrepancy (AMD), marginal gap (MG), and internal discrepancies at the chamfer, axial, line angle, and occlusal regions. Replica thicknesses were quantified under a digital microscope. Data were analyzed with a 1-way repeated measures analysis of variance, with fabrication condition treated as a within-subject factor. Post hoc pairwise comparisons were adjusted with the Holm procedure, and partial η<sup>2</sup> values were calculated to quantify effect size (α=.05).</div><div><h3>Results</h3><div>Fabrication condition significantly affected AMD, MG, chamfer discrepancy, angle discrepancy, and occlusal discrepancy in the omnibus repeated-measures ANOVA (all <em>P</em>&lt;.05), but not axial wall discrepancy (<em>P</em>=.073). Holm adjusted pairwise comparisons showed significant differences for AMD, angle discrepancy, and occlusal discrepancy (all <em>P</em>&lt;.05), whereas no adjusted pairwise difference remained significant for MG or chamfer discrepancy (<em>P</em>&gt;.05).</div></div><div>Fabrication condition significantly affected AMD, MG, chamfer discrepancy, angle discrepancy, and occlusal discrepancy in the omnibus repeated-measures ANOVA (all <em>P</em>&lt;.05), but not axial wall discrepancy (<em>P</em>=.073). Holm adjusted pairwise comparisons showed significant differences for AMD, angle discrepancy, and occlusal discrepancy (all <em>P</em>&lt;.05), whereas no adjusted pairwise difference remained significant for MG or chamfer discrepancy (<em>P</em>&gt;.05).</div><div><h3>Conclusions</h3><div>Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientations resulted in inferior adaptation, particularly at the occlusal surface. Build orientation is therefore a critical parameter for DLP printed zirconia crowns using this specific system and should be carefully controlled to achieve acceptable adaptation in clinical practice.</div></div><div>Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientations resulted in inferior adaptation, particularly at the occlusal surface. Build orientation is therefore a critical parameter for DLP printed zirconia crowns using this specific system and should be carefully controlled to achieve acceptable adaptation in clinical practice.</div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"136 4","pages":"Pages 1097-1104"},"PeriodicalIF":5.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S002239132600466X","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

Digital light processing (DLP) 3-dimensional (3D) printing enables the additive fabrication of monolithic zirconia crowns; however, the effect of build orientation on their marginal and internal discrepancies in vivo, relative to conventionally milled zirconia crowns, remains insufficiently characterized.
Digital light processing (DLP) 3-dimensional (3D) printing enables the additive fabrication of monolithic zirconia crowns; however, the effect of build orientation on their marginal and internal discrepancies in vivo, relative to conventionally milled zirconia crowns, remains insufficiently characterized.

Purpose

The purpose of this clinical study was to compare the marginal and internal discrepancies of zirconia crowns fabricated by conventional milling and by DLP 3D printing and to evaluate the influence of build orientation (0, 45, and 90 degrees) on the fit of DLP- printed crowns.
The purpose of this clinical study was to compare the marginal and internal discrepancies of zirconia crowns fabricated by conventional milling and by DLP 3D printing and to evaluate the influence of build orientation (0, 45, and 90 degrees) on the fit of DLP- printed crowns.

Material and methods

Ten participants requiring a single posterior zirconia crown in the maxilla or mandible were enrolled. For each participant, 4 crowns with identical designs were fabricated: 1 milled crown (Ceramill Motion 2; Amann Girrbach AG) and 3 DLP-printed crowns (TD 6; 3D Controls Co Ltd) at build orientations of 0, 45, and 90 degrees. 4Y PSZ zirconia blocks (Ceramill Zolid FX; Amann Girrbach AG) and a 3Y TZP zirconia slurry (3DCera; 3D Controls Co Ltd) were used. The silicone replica technique (Fit Checker; GC Corp) was used to measure the absolute marginal discrepancy (AMD), marginal gap (MG), and internal discrepancies at the chamfer, axial, line angle, and occlusal regions. Replica thicknesses were quantified under a digital microscope. Data were analyzed with a 1-way repeated measures analysis of variance, with fabrication condition treated as a within-subject factor. Post hoc pairwise comparisons were adjusted with the Holm procedure, and partial η2 values were calculated to quantify effect size (α=.05).
Ten participants requiring a single posterior zirconia crown in the maxilla or mandible were enrolled. For each participant, 4 crowns with identical designs were fabricated: 1 milled crown (Ceramill Motion 2; Amann Girrbach AG) and 3 DLP-printed crowns (TD 6; 3D Controls Co Ltd) at build orientations of 0, 45, and 90 degrees. 4Y PSZ zirconia blocks (Ceramill Zolid FX; Amann Girrbach AG) and a 3Y TZP zirconia slurry (3DCera; 3D Controls Co Ltd) were used. The silicone replica technique (Fit Checker; GC Corp) was used to measure the absolute marginal discrepancy (AMD), marginal gap (MG), and internal discrepancies at the chamfer, axial, line angle, and occlusal regions. Replica thicknesses were quantified under a digital microscope. Data were analyzed with a 1-way repeated measures analysis of variance, with fabrication condition treated as a within-subject factor. Post hoc pairwise comparisons were adjusted with the Holm procedure, and partial η2 values were calculated to quantify effect size (α=.05).

Results

Fabrication condition significantly affected AMD, MG, chamfer discrepancy, angle discrepancy, and occlusal discrepancy in the omnibus repeated-measures ANOVA (all P<.05), but not axial wall discrepancy (P=.073). Holm adjusted pairwise comparisons showed significant differences for AMD, angle discrepancy, and occlusal discrepancy (all P<.05), whereas no adjusted pairwise difference remained significant for MG or chamfer discrepancy (P>.05).
Fabrication condition significantly affected AMD, MG, chamfer discrepancy, angle discrepancy, and occlusal discrepancy in the omnibus repeated-measures ANOVA (all P<.05), but not axial wall discrepancy (P=.073). Holm adjusted pairwise comparisons showed significant differences for AMD, angle discrepancy, and occlusal discrepancy (all P<.05), whereas no adjusted pairwise difference remained significant for MG or chamfer discrepancy (P>.05).

Conclusions

Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientations resulted in inferior adaptation, particularly at the occlusal surface. Build orientation is therefore a critical parameter for DLP printed zirconia crowns using this specific system and should be carefully controlled to achieve acceptable adaptation in clinical practice.
Zirconia crowns fabricated at 0-degrees build orientation using the TD-6 DLP printer and 3DCera 3Y TZP slurry exhibited marginal and internal discrepancies comparable with those of Ceramill Zolid FX 4Y PSZ conventionally milled crowns, whereas 45- and 90-degree build orientations resulted in inferior adaptation, particularly at the occlusal surface. Build orientation is therefore a critical parameter for DLP printed zirconia crowns using this specific system and should be carefully controlled to achieve acceptable adaptation in clinical practice.
构建方位对数字光处理3D打印氧化锆冠边缘和内部差异影响的临床研究
问题说明:数字光处理(DLP)三维(3D)打印使单片氧化锆冠的增材制造成为可能;然而,相对于传统磨铣的氧化锆冠,构建取向对其体内边缘和内部差异的影响仍然没有充分的表征。目的:本临床研究的目的是比较传统铣刀和DLP 3D打印制备的氧化锆冠的边缘和内部差异,并评估构建方向(0度、45度和90度)对DLP打印冠贴合的影响。材料和方法:10名需要在上颌骨或下颌骨安装单一后氧化锆冠的参与者被纳入研究。对于每个参与者,制作了4个具有相同设计的冠:1个铣削冠(Ceramill Motion 2; Amann Girrbach AG)和3个dlp打印冠(TD 6; 3D Controls Co Ltd),构建方向为0度,45度和90度。使用4Y PSZ氧化锆块(Ceramill Zolid FX; Amann Girrbach AG)和3Y TZP氧化锆浆(3DCera; 3D Controls Co Ltd)。使用硅胶复制技术(Fit Checker; GC Corp)测量绝对边缘差异(AMD),边缘间隙(MG)以及倒角,轴向,线角和咬合区域的内部差异。在数码显微镜下定量复制厚度。数据分析采用单向重复测量方差分析,制作条件作为受试者内因素。采用Holm方法调整事后两两比较,计算偏η2值以量化效应大小(α= 0.05)。结果:在综合重复测量方差分析中,制作条件对AMD、MG、倒角差异、角度差异和咬合差异有显著影响(均p < 0.05)。结论:使用TD-6 DLP打印机和3DCera 3Y TZP泥浆在0度构建方向下制作的氧化锆冠与Ceramill Zolid FX 4Y PSZ常规铣制冠相比,具有边缘和内部差异,而45度和90度构建方向导致适应性较差,特别是在咬合表面。因此,构建方向是使用该特定系统的DLP打印氧化锆冠的关键参数,应该仔细控制以在临床实践中获得可接受的适应性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书