Characterization Study of a Helium Cold Atmospheric-Pressure Plasma Jet and Its Application in Plasma-Mediated Root Canal Irrigation

IF 3.8 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Abhijit Mishra;Sushma Jangra;Ritesh Mishra;Shikha Pandey;P. Soundharrajan;Sarika Prabhakar Kombade;Pravin Kumar;Ram Prakash
{"title":"Characterization Study of a Helium Cold Atmospheric-Pressure Plasma Jet and Its Application in Plasma-Mediated Root Canal Irrigation","authors":"Abhijit Mishra;Sushma Jangra;Ritesh Mishra;Shikha Pandey;P. Soundharrajan;Sarika Prabhakar Kombade;Pravin Kumar;Ram Prakash","doi":"10.1109/TRPMS.2025.3628120","DOIUrl":null,"url":null,"abstract":"This study focuses on the design and optimization of a cold atmospheric-pressure plasma (CAP) jet, particularly targeting plasma-mediated root canal irrigation for smear layer removal and Enterococcus faecalis disinfection. The dielectric barrier discharge (DBD)-based CAP jet, powered by a bipolar pulsed power supply, was systematically optimized by varying applied voltage, frequency, and helium gas flow rate to achieve optimal plasma parameters. The CAP jet, operating in a buoyant axisymmetric jet configuration, exhibited a transition from laminar to turbulent flow at helium flow rates exceeding 4 slpm corresponding Reynolds number of ~400. optical emission spectroscopy (OES) was utilized to identify species generated and determine plasma parameters, with the collisional–radiative (CR) model revealing a nonequilibrium nature characterized by electron density (<inline-formula> <tex-math>${n} {_{e} }~\\sim ~10{^{{1}}} {^{{3}}}$ </tex-math></inline-formula> cm<inline-formula> <tex-math>${}^{\\text {-3}}$ </tex-math></inline-formula>), electron temperature (<inline-formula> <tex-math>${T} {_{\\text {re}}}~\\sim ~0.35$ </tex-math></inline-formula> eV), and plasma gas temperature (<inline-formula> <tex-math>${T} {_{g} }~\\sim $ </tex-math></inline-formula> 305 K) under optimized conditions (4.5 kV, 20 kHz, 4 slpm). Fifty-Six mandibular premolars divided into four groups equally were irrigated with Normal saline solution (control) and CAP jet for 2, 5, and 10 min, respectively. Scanning electron microscope (SEM) imaging and disinfection analysis demonstrated significant improvements in smear layer removal and a ~5 log reduction in E. faecalis count, respectively. Smear layer removal was evaluated using the Kruskal–Wallis test, followed by Dunn’s post hoc analysis, whereas differences in bacterial load reduction across various CAP treatment times were analyzed using one-way ANOVA with Tukey’s honest significant difference (HSD) test for multiple comparisons. Safety considerations for medical applications, including gas temperature, leakage currents, and ozone emissions, were also evaluated according to DIN-specification 91315 (General requirements for plasma sources in medicine). These results underscore the promising application of plasma-mediated root canal irrigation, offering minimally invasive dental procedures, providing a foundation for further development and clinical translation in endodontics.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"10 6","pages":"995-1009"},"PeriodicalIF":3.8000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11224948/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/11/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

This study focuses on the design and optimization of a cold atmospheric-pressure plasma (CAP) jet, particularly targeting plasma-mediated root canal irrigation for smear layer removal and Enterococcus faecalis disinfection. The dielectric barrier discharge (DBD)-based CAP jet, powered by a bipolar pulsed power supply, was systematically optimized by varying applied voltage, frequency, and helium gas flow rate to achieve optimal plasma parameters. The CAP jet, operating in a buoyant axisymmetric jet configuration, exhibited a transition from laminar to turbulent flow at helium flow rates exceeding 4 slpm corresponding Reynolds number of ~400. optical emission spectroscopy (OES) was utilized to identify species generated and determine plasma parameters, with the collisional–radiative (CR) model revealing a nonequilibrium nature characterized by electron density ( ${n} {_{e} }~\sim ~10{^{{1}}} {^{{3}}}$ cm ${}^{\text {-3}}$ ), electron temperature ( ${T} {_{\text {re}}}~\sim ~0.35$ eV), and plasma gas temperature ( ${T} {_{g} }~\sim $ 305 K) under optimized conditions (4.5 kV, 20 kHz, 4 slpm). Fifty-Six mandibular premolars divided into four groups equally were irrigated with Normal saline solution (control) and CAP jet for 2, 5, and 10 min, respectively. Scanning electron microscope (SEM) imaging and disinfection analysis demonstrated significant improvements in smear layer removal and a ~5 log reduction in E. faecalis count, respectively. Smear layer removal was evaluated using the Kruskal–Wallis test, followed by Dunn’s post hoc analysis, whereas differences in bacterial load reduction across various CAP treatment times were analyzed using one-way ANOVA with Tukey’s honest significant difference (HSD) test for multiple comparisons. Safety considerations for medical applications, including gas temperature, leakage currents, and ozone emissions, were also evaluated according to DIN-specification 91315 (General requirements for plasma sources in medicine). These results underscore the promising application of plasma-mediated root canal irrigation, offering minimally invasive dental procedures, providing a foundation for further development and clinical translation in endodontics.
氦冷常压等离子体射流的表征及其在等离子体介导根管冲洗中的应用研究
本研究的重点是设计和优化冷常压等离子体(CAP)射流,特别是针对等离子体介导的根管冲洗去除涂抹层和粪肠球菌消毒。基于介质阻挡放电(DBD)的CAP射流由双极脉冲电源供电,通过改变施加电压、频率和氦气流量来系统优化,以获得最佳等离子体参数。CAP射流以浮力轴对称射流形式运行,当氦流速率超过4 slpm时,相应的雷诺数为~400,CAP射流由层流向湍流过渡。利用光学发射光谱(OES)识别产生的物质并确定等离子体参数,碰撞辐射(CR)模型揭示了在优化条件(4.5 kV, 20 kHz, 4 slpm)下电子密度(${n} {_{e}}~\sim ~10{^{{1}}} {^{{3}}}$ cm ${}} {\text{-3}}$)、电子温度(${T} {_ \text {re}}}~\sim ~0.35$ eV)和等离子体气体温度(${T} {_{g}}~\sim $ 305 K)的非平衡性质。56颗下颌前磨牙随机分为4组,分别用生理盐水(对照)和CAP喷射液冲洗2、5、10 min。扫描电镜(SEM)成像和消毒分析显示,涂片层的去除和粪肠球菌计数分别减少了约5倍。涂片层去除采用Kruskal-Wallis检验进行评估,随后采用Dunn事后分析,而不同CAP治疗时间细菌负荷减少的差异采用单因素方差分析和Tukey的诚实显著差异(HSD)检验进行多重比较。医疗应用的安全考虑因素,包括气体温度、泄漏电流和臭氧排放,也根据din规范91315(医学中等离子体源的一般要求)进行了评估。这些结果强调了等离子体介导的根管灌洗的应用前景,提供了微创牙科手术,为牙髓学的进一步发展和临床应用奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书