Zero-Shot Spatio–Temporal Interpolation Using Unsupervised Learning for CT Perfusion With Increased Sampling Interval

IF 3.8 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Yu-Chun Lin;Chi-Kuang Liu;Hsuan-Ming Huang
{"title":"Zero-Shot Spatio–Temporal Interpolation Using Unsupervised Learning for CT Perfusion With Increased Sampling Interval","authors":"Yu-Chun Lin;Chi-Kuang Liu;Hsuan-Ming Huang","doi":"10.1109/TRPMS.2025.3649121","DOIUrl":null,"url":null,"abstract":"Computed tomography perfusion (CTP) is recognized as a valuable tool for acute stroke diagnosis and management. Increasing the temporal sampling interval is a simple way to reduce radiation exposure, but it results in low temporal resolution that may fail to capture rapid perfusion change. To address this issue, we proposed a novel zero-shot spatio–temporal interpolation method that used unsupervised learning to restore CTP images with increased temporal sampling interval. Real brain CTP data with a 0.5-s sampling interval were quarterly subsampled to simulate a long sampling interval (i.e., 2-s) protocol. Then, the one-quarter subsampled CTP images were restored to the complete CTP images by using the proposed method. Finally, perfusion parameters were calculated from the complete and restored CTP images. Compared to the temporally subsampled and linearly interpolated (LI) CTP images, the unsupervised learning-restored CTP images produced perfusion maps more closely aligned with those derived from the completed CTP images, in terms of structural similarity index, mean absolute difference, and contrast-to-noise ratio. Moreover, the means relative differences obtained from the proposed method were lower than those obtained from the LI method in all cases. Our preliminary study shows that using unsupervised learning to restore CTP image frames from the CTP scan with an increased temporal sampling interval is feasible, indicating the possibility of reducing the radiation dose of CTP scans.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"10 6","pages":"920-929"},"PeriodicalIF":3.8000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11319326/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Computed tomography perfusion (CTP) is recognized as a valuable tool for acute stroke diagnosis and management. Increasing the temporal sampling interval is a simple way to reduce radiation exposure, but it results in low temporal resolution that may fail to capture rapid perfusion change. To address this issue, we proposed a novel zero-shot spatio–temporal interpolation method that used unsupervised learning to restore CTP images with increased temporal sampling interval. Real brain CTP data with a 0.5-s sampling interval were quarterly subsampled to simulate a long sampling interval (i.e., 2-s) protocol. Then, the one-quarter subsampled CTP images were restored to the complete CTP images by using the proposed method. Finally, perfusion parameters were calculated from the complete and restored CTP images. Compared to the temporally subsampled and linearly interpolated (LI) CTP images, the unsupervised learning-restored CTP images produced perfusion maps more closely aligned with those derived from the completed CTP images, in terms of structural similarity index, mean absolute difference, and contrast-to-noise ratio. Moreover, the means relative differences obtained from the proposed method were lower than those obtained from the LI method in all cases. Our preliminary study shows that using unsupervised learning to restore CTP image frames from the CTP scan with an increased temporal sampling interval is feasible, indicating the possibility of reducing the radiation dose of CTP scans.
基于无监督学习的CT灌注零间隔时空插值
计算机断层扫描灌注(CTP)被认为是急性脑卒中诊断和治疗的有价值的工具。增加时间采样间隔是减少辐射暴露的一种简单方法,但它会导致时间分辨率低,可能无法捕捉快速灌注变化。为了解决这个问题,我们提出了一种新的零镜头时空插值方法,该方法使用无监督学习来恢复CTP图像,并增加时间采样间隔。每季度对0.5 s采样间隔的真实脑CTP数据进行次采样,以模拟长采样间隔(即2-s)的协议。然后,利用该方法将四分之一的下采样CTP图像恢复为完整的CTP图像。最后,从完整和恢复的CTP图像中计算灌注参数。与时间下采样和线性插值(LI) CTP图像相比,无监督学习恢复的CTP图像产生的灌注图在结构相似性指数、平均绝对差和对比噪声比方面与完成的CTP图像产生的灌注图更接近。此外,在所有情况下,该方法得到的平均相对差都小于LI方法得到的平均相对差。我们的初步研究表明,使用无监督学习从CTP扫描中恢复CTP图像帧,增加时间采样间隔是可行的,这表明了降低CTP扫描辐射剂量的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书