Dynamic biophysical coupling in bioelectronic interfaces for peripheral nerve modulation

IF 34.8
Weitong Pan  (, ), Jianjun Yang  (, ), Yunlong Zhao  (, ), Zhigang Gao  (, ), Haitao Liu  (, ), Daqing Ma  (, )
{"title":"Dynamic biophysical coupling in bioelectronic interfaces for peripheral nerve modulation","authors":"Weitong Pan \n (, ), Jianjun Yang \n (, ), Yunlong Zhao \n (, ), Zhigang Gao \n (, ), Haitao Liu \n (, ), Daqing Ma \n (, )","doi":"10.1038/s44287-026-00301-x","DOIUrl":null,"url":null,"abstract":"Peripheral nerve interfaces provide a bidirectional electrical link between implanted electronics and the peripheral nervous system, supporting therapies for sensory restoration, motor control and chronic disease management. Their long-term performance depends less on how well signals are transmitted at implantation and more on how the electrode–tissue relationship changes, as impedance, threshold, signal fidelity and selectivity drift over months to years. This Review describes these changes through dynamic biophysical coupling, in which mechanical, geometric, electrochemical, biochemical and biological variables co-evolve at the electrode–tissue interface and together determine how the device functions. In this view, keeping coupling within a useful operating window is not a one-time goal set at implantation but a state that must be maintained through coordinated design across materials, device structures, anatomy-specific implantation and system design. We then consider how coupling is measured, modelled and evaluated over the long term, and identify the shared metrics that would make next-generation peripheral nerve interfaces predictable and clinically scalable. Peripheral nerve interfaces typically fail not from acute signal loss but from slow drift in the electrode–tissue relationship. This Review reframes that drift through dynamic biophysical coupling, a unifying view of how materials, structures, anatomy and feedback control together keep interfaces stable, selective and predictable across years of implantation.","PeriodicalId":501701,"journal":{"name":"Nature Reviews Electrical Engineering","volume":"3 7","pages":"450-464"},"PeriodicalIF":34.8000,"publicationDate":"2026-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nature Reviews Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.nature.com/articles/s44287-026-00301-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Peripheral nerve interfaces provide a bidirectional electrical link between implanted electronics and the peripheral nervous system, supporting therapies for sensory restoration, motor control and chronic disease management. Their long-term performance depends less on how well signals are transmitted at implantation and more on how the electrode–tissue relationship changes, as impedance, threshold, signal fidelity and selectivity drift over months to years. This Review describes these changes through dynamic biophysical coupling, in which mechanical, geometric, electrochemical, biochemical and biological variables co-evolve at the electrode–tissue interface and together determine how the device functions. In this view, keeping coupling within a useful operating window is not a one-time goal set at implantation but a state that must be maintained through coordinated design across materials, device structures, anatomy-specific implantation and system design. We then consider how coupling is measured, modelled and evaluated over the long term, and identify the shared metrics that would make next-generation peripheral nerve interfaces predictable and clinically scalable. Peripheral nerve interfaces typically fail not from acute signal loss but from slow drift in the electrode–tissue relationship. This Review reframes that drift through dynamic biophysical coupling, a unifying view of how materials, structures, anatomy and feedback control together keep interfaces stable, selective and predictable across years of implantation.

Abstract Image

周围神经调节的生物电子接口动态生物物理耦合
外周神经接口提供了植入电子设备和外周神经系统之间的双向电连接,支持感觉恢复、运动控制和慢性疾病管理的治疗。由于阻抗、阈值、信号保真度和选择性在几个月到几年的时间内漂移,它们的长期性能不太取决于植入时信号传输的好坏,而更多地取决于电极与组织的关系如何变化。这篇综述通过动态生物物理耦合描述了这些变化,其中机械、几何、电化学、生化和生物学变量在电极-组织界面共同进化,共同决定了设备的功能。从这个角度来看,在一个有用的操作窗口内保持耦合并不是植入时设定的一次性目标,而是必须通过跨材料、设备结构、解剖特异性植入和系统设计的协调设计来维持的状态。然后,我们考虑如何在长期内测量、建模和评估耦合,并确定共享指标,使下一代周围神经接口可预测和临床可扩展。周围神经接口的典型失效不是由于急性信号丢失,而是由于电极-组织关系的缓慢漂移。这篇综述通过动态生物物理耦合重新构建了漂移,这是一种统一的观点,即材料、结构、解剖和反馈控制如何在多年的植入过程中共同保持界面的稳定性、选择性和可预测性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书