Lock versus merge: How software algorithms modulate the trueness of trim-rescan versus continuous digital scans in complex treatments

IF 5.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Prosthetic Dentistry Pub Date : 2026-10-01 Epub Date: 2026-07-09 DOI:10.1016/j.prosdent.2026.06.027
Aya M. Khalil BDS, Mohamed M. El Kateb BDS, MSD, PhD, Noha Morsy BDS, MSD, PhD
{"title":"Lock versus merge: How software algorithms modulate the trueness of trim-rescan versus continuous digital scans in complex treatments","authors":"Aya M. Khalil BDS,&nbsp;Mohamed M. El Kateb BDS, MSD, PhD,&nbsp;Noha Morsy BDS, MSD, PhD","doi":"10.1016/j.prosdent.2026.06.027","DOIUrl":null,"url":null,"abstract":"<div><h3>Statement of problem</h3><div>The trim-rescan function has been advocated for capturing multiple finish lines, yet its accuracy appears inconsistent across studies. This discrepancy may stem from fundamental differences in how the intraoral scanner (IOS) software program handles scan alignment and merging, a factor poorly understood in the context of multiple preparations.</div></div><div>The trim-rescan function has been advocated for capturing multiple finish lines, yet its accuracy appears inconsistent across studies. This discrepancy may stem from fundamental differences in how the intraoral scanner (IOS) software program handles scan alignment and merging, a factor poorly understood in the context of multiple preparations.</div><div><h3>Purpose</h3><div>This in vitro study aimed to investigate the influence of scanner-specific software algorithms by comparing the trueness of trim-rescan versus continuous scanning for a multi-abutment arch using 3 IOSs: the CS 3700 and Medit i700 (with \"lock\" feature) versus the CEREC Omnicam (without).</div></div><div>This in vitro study aimed to investigate the influence of scanner-specific software algorithms by comparing the trueness of trim-rescan versus continuous scanning for a multi-abutment arch using 3 IOSs: the CS 3700 and Medit i700 (with \"lock\" feature) versus the CEREC Omnicam (without).</div><div><h3>Material and methods</h3><div>A maxillary definitive cast with 8 prepared abutments was fabricated via 3-dimensional (3D) printing. A laboratory scanner (Medit T710) provided the reference cast. The cast was scanned (<em>n</em>=15 per group) using 3 IOSs (CS 3700, Medit i700, CEREC Omnicam) with both continuous and trim-rescan protocols. For trim-rescan, the protocol adhered to each scanner's unique software workflow. Trueness was assessed by computing the root mean square (RMS) error between test and reference scans after best-fit alignment. Data were analyzed using 2-way ANOVA, with complementary robust methods including Welch ANOVA and Games-Howell post hoc tests (α=.05). Effect sizes with 95% confidence intervals were calculated.</div></div><div>A maxillary definitive cast with 8 prepared abutments was fabricated via 3-dimensional (3D) printing. A laboratory scanner (Medit T710) provided the reference cast. The cast was scanned (<em>n</em>=15 per group) using 3 IOSs (CS 3700, Medit i700, CEREC Omnicam) with both continuous and trim-rescan protocols. For trim-rescan, the protocol adhered to each scanner's unique software workflow. Trueness was assessed by computing the root mean square (RMS) error between test and reference scans after best-fit alignment. Data were analyzed using 2-way ANOVA, with complementary robust methods including Welch ANOVA and Games-Howell post hoc tests (α=.05). Effect sizes with 95% confidence intervals were calculated.</div><div><h3>Results</h3><div>Scanner type significantly affected trueness (<em>P</em>&lt;.001, partial η²=0.552, 95% CI [0.412 to 0.648]), with Medit i700 demonstrating the highest trueness overall. A significant main effect was also found for Technique (<em>P</em>=.015, partial η²=0.068, 95% CI [0.008 to 0.172]). The interaction between scanner type and scanning method was not significant (<em>P</em>=.852, partial η²=0.004, 95% CI [0.000 to 0.028]), indicating that the effect of scanning method was consistent across scanners. Post hoc analysis using the Welch <em>t</em> test to account for unequal variances revealed the trim-rescan method provided significantly better trueness only for the CEREC Omnicam (44.40 ±6.17 µm) compared to its continuous scan (53.87 ±15.77 µm); mean difference 9.47 µm, 95% CI [0.287 to 18.646], <em>P</em>=.044, Cohen d=0.791, 95% CI [0.039 to 1.529]. For CS 3700 and Medit i700, trueness between methods was not statistically different with <em>P</em>=.205 for Medit and <em>P</em>=.288 for CS 3700.</div></div><div>Scanner type significantly affected trueness (<em>P</em>&lt;.001, partial η²=0.552, 95% CI [0.412 to 0.648]), with Medit i700 demonstrating the highest trueness overall. A significant main effect was also found for Technique (<em>P</em>=.015, partial η²=0.068, 95% CI [0.008 to 0.172]). The interaction between scanner type and scanning method was not significant (<em>P</em>=.852, partial η²=0.004, 95% CI [0.000 to 0.028]), indicating that the effect of scanning method was consistent across scanners. Post hoc analysis using the Welch <em>t</em> test to account for unequal variances revealed the trim-rescan method provided significantly better trueness only for the CEREC Omnicam (44.40 ±6.17 µm) compared to its continuous scan (53.87 ±15.77 µm); mean difference 9.47 µm, 95% CI [0.287 to 18.646], <em>P</em>=.044, Cohen d=0.791, 95% CI [0.039 to 1.529]. For CS 3700 and Medit i700, trueness between methods was not statistically different with <em>P</em>=.205 for Medit and <em>P</em>=.288 for CS 3700.</div><div><h3>Conclusions</h3><div>The effect of the trim-rescan function on scanning trueness was not universal but was critically dependent on the IOS and its underlying software algorithm. Scanners lacking a \"lock\" feature, such as CEREC Omnicam, may derive significant accuracy benefits from the trim-rescan technique for multiple abutments, whereas scanners with advanced registration locking may achieve equivalent accuracy with either method. Clinicians and researchers must consider software workflow design when selecting a scanning protocol.</div></div><div>The effect of the trim-rescan function on scanning trueness was not universal but was critically dependent on the IOS and its underlying software algorithm. Scanners lacking a \"lock\" feature, such as CEREC Omnicam, may derive significant accuracy benefits from the trim-rescan technique for multiple abutments, whereas scanners with advanced registration locking may achieve equivalent accuracy with either method. Clinicians and researchers must consider software workflow design when selecting a scanning protocol.</div>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":"136 4","pages":"Pages e47-e53"},"PeriodicalIF":5.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022391326004634","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/7/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem

The trim-rescan function has been advocated for capturing multiple finish lines, yet its accuracy appears inconsistent across studies. This discrepancy may stem from fundamental differences in how the intraoral scanner (IOS) software program handles scan alignment and merging, a factor poorly understood in the context of multiple preparations.
The trim-rescan function has been advocated for capturing multiple finish lines, yet its accuracy appears inconsistent across studies. This discrepancy may stem from fundamental differences in how the intraoral scanner (IOS) software program handles scan alignment and merging, a factor poorly understood in the context of multiple preparations.

Purpose

This in vitro study aimed to investigate the influence of scanner-specific software algorithms by comparing the trueness of trim-rescan versus continuous scanning for a multi-abutment arch using 3 IOSs: the CS 3700 and Medit i700 (with "lock" feature) versus the CEREC Omnicam (without).
This in vitro study aimed to investigate the influence of scanner-specific software algorithms by comparing the trueness of trim-rescan versus continuous scanning for a multi-abutment arch using 3 IOSs: the CS 3700 and Medit i700 (with "lock" feature) versus the CEREC Omnicam (without).

Material and methods

A maxillary definitive cast with 8 prepared abutments was fabricated via 3-dimensional (3D) printing. A laboratory scanner (Medit T710) provided the reference cast. The cast was scanned (n=15 per group) using 3 IOSs (CS 3700, Medit i700, CEREC Omnicam) with both continuous and trim-rescan protocols. For trim-rescan, the protocol adhered to each scanner's unique software workflow. Trueness was assessed by computing the root mean square (RMS) error between test and reference scans after best-fit alignment. Data were analyzed using 2-way ANOVA, with complementary robust methods including Welch ANOVA and Games-Howell post hoc tests (α=.05). Effect sizes with 95% confidence intervals were calculated.
A maxillary definitive cast with 8 prepared abutments was fabricated via 3-dimensional (3D) printing. A laboratory scanner (Medit T710) provided the reference cast. The cast was scanned (n=15 per group) using 3 IOSs (CS 3700, Medit i700, CEREC Omnicam) with both continuous and trim-rescan protocols. For trim-rescan, the protocol adhered to each scanner's unique software workflow. Trueness was assessed by computing the root mean square (RMS) error between test and reference scans after best-fit alignment. Data were analyzed using 2-way ANOVA, with complementary robust methods including Welch ANOVA and Games-Howell post hoc tests (α=.05). Effect sizes with 95% confidence intervals were calculated.

Results

Scanner type significantly affected trueness (P<.001, partial η²=0.552, 95% CI [0.412 to 0.648]), with Medit i700 demonstrating the highest trueness overall. A significant main effect was also found for Technique (P=.015, partial η²=0.068, 95% CI [0.008 to 0.172]). The interaction between scanner type and scanning method was not significant (P=.852, partial η²=0.004, 95% CI [0.000 to 0.028]), indicating that the effect of scanning method was consistent across scanners. Post hoc analysis using the Welch t test to account for unequal variances revealed the trim-rescan method provided significantly better trueness only for the CEREC Omnicam (44.40 ±6.17 µm) compared to its continuous scan (53.87 ±15.77 µm); mean difference 9.47 µm, 95% CI [0.287 to 18.646], P=.044, Cohen d=0.791, 95% CI [0.039 to 1.529]. For CS 3700 and Medit i700, trueness between methods was not statistically different with P=.205 for Medit and P=.288 for CS 3700.
Scanner type significantly affected trueness (P<.001, partial η²=0.552, 95% CI [0.412 to 0.648]), with Medit i700 demonstrating the highest trueness overall. A significant main effect was also found for Technique (P=.015, partial η²=0.068, 95% CI [0.008 to 0.172]). The interaction between scanner type and scanning method was not significant (P=.852, partial η²=0.004, 95% CI [0.000 to 0.028]), indicating that the effect of scanning method was consistent across scanners. Post hoc analysis using the Welch t test to account for unequal variances revealed the trim-rescan method provided significantly better trueness only for the CEREC Omnicam (44.40 ±6.17 µm) compared to its continuous scan (53.87 ±15.77 µm); mean difference 9.47 µm, 95% CI [0.287 to 18.646], P=.044, Cohen d=0.791, 95% CI [0.039 to 1.529]. For CS 3700 and Medit i700, trueness between methods was not statistically different with P=.205 for Medit and P=.288 for CS 3700.

Conclusions

The effect of the trim-rescan function on scanning trueness was not universal but was critically dependent on the IOS and its underlying software algorithm. Scanners lacking a "lock" feature, such as CEREC Omnicam, may derive significant accuracy benefits from the trim-rescan technique for multiple abutments, whereas scanners with advanced registration locking may achieve equivalent accuracy with either method. Clinicians and researchers must consider software workflow design when selecting a scanning protocol.
The effect of the trim-rescan function on scanning trueness was not universal but was critically dependent on the IOS and its underlying software algorithm. Scanners lacking a "lock" feature, such as CEREC Omnicam, may derive significant accuracy benefits from the trim-rescan technique for multiple abutments, whereas scanners with advanced registration locking may achieve equivalent accuracy with either method. Clinicians and researchers must consider software workflow design when selecting a scanning protocol.
锁定与合并:在复杂的治疗中,软件算法如何调节微调扫描与连续数字扫描的准确性。
问题陈述:trim-rescan功能一直被提倡用于捕获多个终点线,但其准确性在研究中似乎不一致。这种差异可能源于口腔内扫描仪(IOS)软件程序处理扫描对齐和合并的基本差异,这是在多种制剂背景下人们知之甚少的一个因素。目的:本体外研究旨在通过比较使用3种iiss (CS 3700和Medit i700(具有“锁定”特征)与CEREC Omnicam(不具有“锁定”特征)对多基牙弓进行trim-rescan和连续扫描的准确性,来研究扫描仪特定软件算法的影响。材料和方法:采用3D打印技术制作上颌终模,共8个预备基台。实验室扫描仪(Medit T710)提供了参考铸型。使用3台ios (CS 3700, Medit i700, CEREC Omnicam)对铸型进行连续扫描和trim扫描(每组15例)。对于trim-rescan,该协议遵循每个扫描仪独特的软件工作流程。通过计算最佳拟合对齐后测试和参考扫描之间的均方根(RMS)误差来评估准确性。数据分析采用双因素方差分析,并辅以Welch方差分析和Games-Howell事后检验(α= 0.05)。计算了95%置信区间的效应量。结论:trim-rescan功能对扫描正确率的影响不是普遍的,而是严重依赖于IOS及其底层软件算法。缺乏“锁定”功能的扫描仪,如CEREC Omnicam,可以从多基台的trim-rescan技术中获得显著的精度优势,而具有高级注册锁定功能的扫描仪可以通过任何一种方法获得相同的精度。临床医生和研究人员在选择扫描方案时必须考虑软件工作流程设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书