{"title":"Subjective-Device-Estimated Sleep Discrepancies in Late-Life Depression: Agreement and Associated Factors.","authors":"Qianlong Wang, Yuandong Gong, Jiacui Ji, Yan Zhang, Meixu Lu, Meiyu Song, Xia Zhang, Yuping Zhao, Qi Miao","doi":"10.31083/AP50350","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study examined the agreement between subjective sleep assessments and device-estimated sleep parameters in patients with late-life depression, and explored potential factors associated with the discrepancies between the two measures.</p><p><strong>Methods: </strong>This cross-sectional study enrolled 94 patients with late-life depression. Device-estimated sleep parameters were obtained via portable sleep respiratory monitoring. Participants also reported the previous night's total sleep time (TST), sleeponset latency (SOL), and sleep efficiency (SE) using a self-designed form. Agreement between subjective and device-estimated measures was evaluated with Bland-Altman analysis. Multivariate regression was conducted to identify factors associated with subjective-device-estimated sleep discrepancies.</p><p><strong>Results: </strong>Compared with device-estimated measures, subjective reports differed significantly across all three sleep parameters (Wilcoxon signed-rank test: TST, <i>Z</i> = -6.94, <i>p</i> < 0.001; SOL, <i>Z</i> = -2.98, <i>p</i> = 0.003; SE, <i>Z</i> = -5.02, <i>p</i> < 0.001). These results indicate a pronounced subjective-device-estimated sleep discrepancy in late-life depression, with subjective underestimation of TST and SE and overestimation of SOL. Greater depressive symptom severity was associated with greater subjective underestimation of TST (<i>p</i> = 0.037), whereas later age at first onset was associated with greater subjective underestimation of SE (<i>p</i> = 0.013). The association between age at first onset and subjective overestimation of SOL observed in the main analysis (<i>p</i> = 0.047) was no longer significant after additional inclusion of sex in the model (<i>p</i> = 0.054).</p><p><strong>Conclusions: </strong>Patients with late-life depression exhibited subjective-device-estimated discrepancies in sleep parameters. Heavier depressive symptom burden was linked to greater underestimation of total sleep time, while later age at first onset was more closely related to underestimation of sleep efficiency. A later age at first onset showed a trend toward an association with overestimation of sleep onset latency, but this finding still requires further validation. In clinical practice, combining device-estimated sleep monitoring with subjective sleep assessment should be considered in order to obtain a more comprehensive understanding of patients' sleep status.</p>","PeriodicalId":72151,"journal":{"name":"Alpha psychiatry","volume":"27 3","pages":"50350"},"PeriodicalIF":2.9000,"publicationDate":"2026-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13339800/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Alpha psychiatry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31083/AP50350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PSYCHIATRY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study examined the agreement between subjective sleep assessments and device-estimated sleep parameters in patients with late-life depression, and explored potential factors associated with the discrepancies between the two measures.
Methods: This cross-sectional study enrolled 94 patients with late-life depression. Device-estimated sleep parameters were obtained via portable sleep respiratory monitoring. Participants also reported the previous night's total sleep time (TST), sleeponset latency (SOL), and sleep efficiency (SE) using a self-designed form. Agreement between subjective and device-estimated measures was evaluated with Bland-Altman analysis. Multivariate regression was conducted to identify factors associated with subjective-device-estimated sleep discrepancies.
Results: Compared with device-estimated measures, subjective reports differed significantly across all three sleep parameters (Wilcoxon signed-rank test: TST, Z = -6.94, p < 0.001; SOL, Z = -2.98, p = 0.003; SE, Z = -5.02, p < 0.001). These results indicate a pronounced subjective-device-estimated sleep discrepancy in late-life depression, with subjective underestimation of TST and SE and overestimation of SOL. Greater depressive symptom severity was associated with greater subjective underestimation of TST (p = 0.037), whereas later age at first onset was associated with greater subjective underestimation of SE (p = 0.013). The association between age at first onset and subjective overestimation of SOL observed in the main analysis (p = 0.047) was no longer significant after additional inclusion of sex in the model (p = 0.054).
Conclusions: Patients with late-life depression exhibited subjective-device-estimated discrepancies in sleep parameters. Heavier depressive symptom burden was linked to greater underestimation of total sleep time, while later age at first onset was more closely related to underestimation of sleep efficiency. A later age at first onset showed a trend toward an association with overestimation of sleep onset latency, but this finding still requires further validation. In clinical practice, combining device-estimated sleep monitoring with subjective sleep assessment should be considered in order to obtain a more comprehensive understanding of patients' sleep status.
背景:本研究考察了老年抑郁症患者主观睡眠评估和设备估计睡眠参数之间的一致性,并探讨了两者之间差异的潜在因素。方法:本横断面研究纳入94例晚期抑郁症患者。通过便携式睡眠呼吸监测获得设备估计的睡眠参数。参与者还使用自行设计的表格报告了前一晚的总睡眠时间(TST)、睡眠发作潜伏期(SOL)和睡眠效率(SE)。用Bland-Altman分析评估主观测量和设备估计测量之间的一致性。进行多变量回归以确定与主观设备估计的睡眠差异相关的因素。结果:与设备估计测量相比,主观报告在所有三个睡眠参数上都有显著差异(Wilcoxon符号秩检验:TST, Z = -6.94, p < 0.001; SOL, Z = -2.98, p = 0.003; SE, Z = -5.02, p < 0.001)。这些结果表明,在晚年抑郁症中,主观设备估计的睡眠差异明显,主观低估TST和SE,高估SOL。更严重的抑郁症状与更严重的主观低估TST相关(p = 0.037),而更晚的首次发病年龄与更大的主观低估SE相关(p = 0.013)。在主要分析中观察到的首次发病年龄与主观高估SOL之间的关联(p = 0.047)在模型中额外纳入性别后不再显著(p = 0.054)。结论:老年抑郁症患者表现出主观装置估计的睡眠参数差异。较重的抑郁症状负担与对总睡眠时间的严重低估有关,而首次发病年龄较晚与对睡眠效率的低估更密切相关。较晚的首次发病年龄显示出与高估睡眠开始潜伏期相关的趋势,但这一发现仍需要进一步验证。在临床实践中,应考虑将设备估计睡眠监测与主观睡眠评估相结合,以便更全面地了解患者的睡眠状态。