CE-MRA-FLOWnet: Fast and Accurate Generative AI-Based Aortic Hemodynamic Mapping from Contrast-Enhanced MRA.

IF 5 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
David Dushfunian, Haben Berhane, Ethan Johnson, Aniket Dehaidrai, Michael Markl, Bradley D Allen
{"title":"CE-MRA-FLOWnet: Fast and Accurate Generative AI-Based Aortic Hemodynamic Mapping from Contrast-Enhanced MRA.","authors":"David Dushfunian, Haben Berhane, Ethan Johnson, Aniket Dehaidrai, Michael Markl, Bradley D Allen","doi":"10.1016/j.jocmr.2026.102773","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>4D flow MRI hemodynamic biomarkers (e.g. peak velocity and wall shear stress [WSS]) have shown promise for improved risk-stratification in patients with thoracic aortic disease (TAD). However, lengthy 4D flow scan times, complex data analysis and need for dedicated expertise limit clinical translation. In this study, we developed a fluid-physics informed deep generative adversarial neural network, CE-MRA-FLOWnet, to predict aortic hemodynamics directly from standard-of-care contrast-enhanced magnetic resonance angiography (CE-MRA) images.</p><p><strong>Methods: </strong>We retrospectively identified 1392 patients (age: 52±12years, 1011 male, 954 with bicuspid aortic valve, BAV; 438 with tricuspid aortic valve, TAV) who underwent paired clinical 4D flow MRI and CE-MRA between 2011 and 2020 for suspected TAD. The CE-MRA-FLOWnet used CE-MRA data (1127 for network training, 265 for testing) to generate a prediction of aortic hemodynamics. 4D flow-measured aortic systolic 3D blood flow velocity vector fields served as ground truth. Analysis included comparison of AI-derived and ground truth aortic systolic peak velocity (PV) and WSS, the relative area of the AAo (%) exposed to elevated WSS, and aortic valve stenosis severity grading. The predictive value of CE-MRA-FLOWnet hemodynamics metrics was assessed in a subgroup of 133 BAV patients with known multi-year adverse outcomes.</p><p><strong>Results: </strong>CE-MRA-FLOWnet training time was 8100mins; inference time per CE-MRA was 0.88±0.05seconds. AI-derived PV showed strong regional agreement and low biases with ground truth 4D flow (0.00-0.04m/s), and relative differences within 10.6%-12.7%. Aortic WSS also demonstrated minimal bias (-0.01-0.04Pa) and close alignment of the area of elevate WSS between AI and 4D flow (19.6±15.1% vs. 19.3±16.2%, p=0.84). AS severity was accurately classified in 88% of cases, with all grading errors limited to a one-grade difference (Kappa 0.84). ROC analysis showed that CE-MRA-FLOWnet derived hemodynamic metrics outperformed diameter alone for predicting adverse outcomes (PV AUC = 0.73-0.76; WSS = 0.83-0.88; diameter = 0.52-0.62).</p><p><strong>Conclusions: </strong>CE-MRA-FLOWnet accurately predicts aortic hemodynamics in TAD patients using standard-of-care CE-MRA images. Our results demonstrate potential for clinical integration by providing physicians with near real-time hemodynamic data from widely available clinical CE-MRA images.</p><p><strong>Clinical perspective: </strong>Approximately 3% of the population has or is at risk for thoracic aortic disease (TAD) which can result in significant complications including progressive aortic dilation and dissection. Historically, aortic diameter measured on CT angiography or MR angiography (MRA) has been the primary marker of risk and TAD patients undergo frequent surveillance imaging to evaluate aortic size and growth. However, it is well established that aortic diameter is an imperfect risk assessment tool and a large percentage of patients who are outside of guideline-endorsed diameter surgical thresholds can have aortic dissection. Recently, aortic hemodynamics measured with 4D flow MRI have shown promise for detecting patients who have higher aortic growth rates and 4D flow derived wall shear stress (WSS) has been linked to histopathologic damage to the aortic wall. Thus, aortic hemodynamic assessment could supplement aortic diameter to improve TAD risk-stratification. Unfortunately, 4D flow MRI is not widely available and can be difficult acquire, analyze, and interpret which has led to low utilization. In this study, we have developed CE-MRA-FLOWnet, a fluid-physics informed generative neural network that quantifies peak systolic aorta hemodynamics using only standard anatomic contrast-enhanced (CE) MRA as input. We found that CE-MRA-FLOWnet peak systolic velocity and WSS quantification is highly accurate compared to 4D flow MRI. We also found that these outputs can accurately grade aortic stenosis severity and are superior to aortic diameter for predicting adverse aortic outcomes. CE-MRA-FLOWnet could significantly expand access these important risk metrics to many more TAD patients.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"102773"},"PeriodicalIF":5.0000,"publicationDate":"2026-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2026.102773","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: 4D flow MRI hemodynamic biomarkers (e.g. peak velocity and wall shear stress [WSS]) have shown promise for improved risk-stratification in patients with thoracic aortic disease (TAD). However, lengthy 4D flow scan times, complex data analysis and need for dedicated expertise limit clinical translation. In this study, we developed a fluid-physics informed deep generative adversarial neural network, CE-MRA-FLOWnet, to predict aortic hemodynamics directly from standard-of-care contrast-enhanced magnetic resonance angiography (CE-MRA) images.

Methods: We retrospectively identified 1392 patients (age: 52±12years, 1011 male, 954 with bicuspid aortic valve, BAV; 438 with tricuspid aortic valve, TAV) who underwent paired clinical 4D flow MRI and CE-MRA between 2011 and 2020 for suspected TAD. The CE-MRA-FLOWnet used CE-MRA data (1127 for network training, 265 for testing) to generate a prediction of aortic hemodynamics. 4D flow-measured aortic systolic 3D blood flow velocity vector fields served as ground truth. Analysis included comparison of AI-derived and ground truth aortic systolic peak velocity (PV) and WSS, the relative area of the AAo (%) exposed to elevated WSS, and aortic valve stenosis severity grading. The predictive value of CE-MRA-FLOWnet hemodynamics metrics was assessed in a subgroup of 133 BAV patients with known multi-year adverse outcomes.

Results: CE-MRA-FLOWnet training time was 8100mins; inference time per CE-MRA was 0.88±0.05seconds. AI-derived PV showed strong regional agreement and low biases with ground truth 4D flow (0.00-0.04m/s), and relative differences within 10.6%-12.7%. Aortic WSS also demonstrated minimal bias (-0.01-0.04Pa) and close alignment of the area of elevate WSS between AI and 4D flow (19.6±15.1% vs. 19.3±16.2%, p=0.84). AS severity was accurately classified in 88% of cases, with all grading errors limited to a one-grade difference (Kappa 0.84). ROC analysis showed that CE-MRA-FLOWnet derived hemodynamic metrics outperformed diameter alone for predicting adverse outcomes (PV AUC = 0.73-0.76; WSS = 0.83-0.88; diameter = 0.52-0.62).

Conclusions: CE-MRA-FLOWnet accurately predicts aortic hemodynamics in TAD patients using standard-of-care CE-MRA images. Our results demonstrate potential for clinical integration by providing physicians with near real-time hemodynamic data from widely available clinical CE-MRA images.

Clinical perspective: Approximately 3% of the population has or is at risk for thoracic aortic disease (TAD) which can result in significant complications including progressive aortic dilation and dissection. Historically, aortic diameter measured on CT angiography or MR angiography (MRA) has been the primary marker of risk and TAD patients undergo frequent surveillance imaging to evaluate aortic size and growth. However, it is well established that aortic diameter is an imperfect risk assessment tool and a large percentage of patients who are outside of guideline-endorsed diameter surgical thresholds can have aortic dissection. Recently, aortic hemodynamics measured with 4D flow MRI have shown promise for detecting patients who have higher aortic growth rates and 4D flow derived wall shear stress (WSS) has been linked to histopathologic damage to the aortic wall. Thus, aortic hemodynamic assessment could supplement aortic diameter to improve TAD risk-stratification. Unfortunately, 4D flow MRI is not widely available and can be difficult acquire, analyze, and interpret which has led to low utilization. In this study, we have developed CE-MRA-FLOWnet, a fluid-physics informed generative neural network that quantifies peak systolic aorta hemodynamics using only standard anatomic contrast-enhanced (CE) MRA as input. We found that CE-MRA-FLOWnet peak systolic velocity and WSS quantification is highly accurate compared to 4D flow MRI. We also found that these outputs can accurately grade aortic stenosis severity and are superior to aortic diameter for predicting adverse aortic outcomes. CE-MRA-FLOWnet could significantly expand access these important risk metrics to many more TAD patients.

ce - mri - flownet:快速准确的基于生成人工智能的对比增强MRA主动脉血流动力学制图
背景:4D血流MRI血流动力学生物标志物(如峰值速度和壁剪切应力[WSS])已显示出改善胸主动脉疾病(TAD)患者风险分层的希望。然而,冗长的4D流扫描时间、复杂的数据分析以及对专业知识的需求限制了临床翻译。在这项研究中,我们开发了一种流体物理深度生成对抗神经网络,ce - mri - flownet,直接从标准护理对比增强磁共振血管造影(CE-MRA)图像预测主动脉血流动力学。方法:我们回顾性分析了1392例(年龄:52±12岁,男性1011例,双尖瓣主动脉瓣(BAV) 954例,三尖瓣主动脉瓣(TAV) 438例)在2011年至2020年期间因疑似TAD接受了配对的临床4D血流MRI和CE-MRA。ce - mri - flownet使用CE-MRA数据(1127用于网络训练,265用于测试)来预测主动脉血流动力学。4D血流测量主动脉收缩期3D血流速度矢量场作为地面真实值。分析包括人工智能得出的和真实的主动脉收缩峰值速度(PV)和WSS的比较,暴露于WSS升高的AAo的相对面积(%),以及主动脉瓣狭窄严重程度分级。在133例已知多年不良结局的BAV患者亚组中评估ce - mri - flownet血流动力学指标的预测价值。结果:ce - mri - flownet训练时间为8100min;每次CE-MRA推断时间为0.88±0.05秒。人工智能反演的PV与地面真值4D流(0.004 ~ 0.04m/s)具有较强的区域一致性和较低的偏差,相对差异在10.6% ~ 12.7%之间。主动脉WSS也表现出最小的偏差(-0.01-0.04Pa),并且在AI和4D血流之间的上升WSS区域紧密对齐(19.6±15.1% vs. 19.3±16.2%,p=0.84)。在88%的病例中,AS的严重程度被准确地分类,所有的评分误差限制在1级以内(Kappa 0.84)。ROC分析显示ce - mri - flownet衍生的血流动力学指标在预测不良结局方面优于单独的内径指标(PV AUC = 0.73-0.76; WSS = 0.83-0.88;内径= 0.52-0.62)。结论:ce - mri - flownet使用标准CE-MRA图像准确预测TAD患者的主动脉血流动力学。我们的研究结果通过为医生提供广泛可用的临床CE-MRA图像的近实时血流动力学数据,展示了临床整合的潜力。临床观点:大约3%的人群有或有患胸主动脉疾病(TAD)的风险,这可能导致严重的并发症,包括进行性主动脉扩张和夹层。从历史上看,通过CT血管造影或MR血管造影(MRA)测量的主动脉直径一直是危险的主要标志,TAD患者经常接受监测成像来评估主动脉大小和生长情况。然而,主动脉直径是一种不完善的风险评估工具,很大一部分超过指南认可的直径手术阈值的患者可能发生主动脉夹层。最近,用4D血流MRI测量的主动脉血流动力学显示出检测主动脉生长速度较高的患者的希望,4D血流衍生的壁剪切应力(WSS)与主动脉壁的组织病理学损伤有关。因此,主动脉血流动力学评估可以补充主动脉直径,以改善TAD风险分层。不幸的是,四维流MRI并没有被广泛使用,并且难以获取、分析和解释,这导致了低利用率。在这项研究中,我们开发了CE- mri - flownet,这是一种流体物理信息生成神经网络,仅使用标准的解剖对比增强(CE) MRA作为输入,就可以量化收缩主动脉血流动力学峰值。我们发现ce - MRI - flownet峰值收缩速度和WSS量化与4D血流MRI相比具有很高的准确性。我们还发现,这些输出可以准确地对主动脉狭窄的严重程度进行分级,并且在预测主动脉不良结局方面优于主动脉直径。ce - mri - flownet可以使更多TAD患者获得这些重要的风险指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书