Bonding Performance of a Bisphenol A-Free Universal Adhesive to Sound and Caries-Affected Dentin.

IF 2.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
C S Garfias, M F De Goes
{"title":"Bonding Performance of a Bisphenol A-Free Universal Adhesive to Sound and Caries-Affected Dentin.","authors":"C S Garfias, M F De Goes","doi":"10.2341/24-170-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Current universal adhesives exhibit unreliable bonding to caries-affected dentin and release bisphenol A (BPA). This study compares a BPA-free universal adhesive with its predecessor (bisphenol-based) to assess bonding performance and interfacial characteristics on sound and caries-affected dentin.</p><p><strong>Methods and materials: </strong>Two hundred forty human molars were used in this study: 120 with sound dentin and 120 with caries-affected dentin (CAD). The dentin surfaces were prepared and bonded with Scotchbond Universal Plus (SBUP/BPA-free) or Scotchbond Universal (SBU/BPA-containing) using etch-and-rinse (ER) or self-etching (SE) modes. Resin-dentin bonded specimens (1 mm2) were stored in water for 24 hours and one year and tested for microtensile bond strength (μTBS). The failure images were analyzed through scanning electron microscopy (SEM). Data were submitted to three-way ANOVA and Bonferroni post hoc tests (α < 0.05). Three additional teeth were prepared for each group for evaluation of adhesive diffusion into dentin by dyeing the adhesives with a fluorochrome (Rhodamine B). After longitudinal sectioning, the generated interfaces were stored for 24 hours and one year, immersed in fluorescein dye and examined under confocal laser scanning microscopy (CLSM) and SEM (n = 3).</p><p><strong>Results: </strong>CAD showed μTBS mean values significantly lower (p < 0.0001) than those of sound dentin for all groups at 24 hours. The SE mode on sound dentin showed no signs of degradation or fluorescein infiltration. SBU in the ER mode (CAD) showed the lowest mean μTBS in both storage periods. The ER mode for both adhesives showed exposed collagen fibrils and fluorescein infiltration underneath the hybrid layer of the sound and CAD over time. Although SBUP showed deeper adhesive diffusion into the CAD, no significant difference in μTBS was found between SBUP (ER and SE) and SBUSE after a year of water storage.</p><p><strong>Conclusion: </strong>Both the BPA-free and BPA-containing adhesives produced similar short- and long-term μTBS to sound dentin. Bond strengths to CAD varied by material and conditioning mode. Qualitative appearance of SEM images suggests that interfacial diffusion in CAD at 24 hours may be enhanced for the BPA-free adhesive. However, both adhesives exhibited degradation after one year of water storage.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"51 2","pages":"135-148"},"PeriodicalIF":2.3000,"publicationDate":"2026-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/24-170-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Current universal adhesives exhibit unreliable bonding to caries-affected dentin and release bisphenol A (BPA). This study compares a BPA-free universal adhesive with its predecessor (bisphenol-based) to assess bonding performance and interfacial characteristics on sound and caries-affected dentin.

Methods and materials: Two hundred forty human molars were used in this study: 120 with sound dentin and 120 with caries-affected dentin (CAD). The dentin surfaces were prepared and bonded with Scotchbond Universal Plus (SBUP/BPA-free) or Scotchbond Universal (SBU/BPA-containing) using etch-and-rinse (ER) or self-etching (SE) modes. Resin-dentin bonded specimens (1 mm2) were stored in water for 24 hours and one year and tested for microtensile bond strength (μTBS). The failure images were analyzed through scanning electron microscopy (SEM). Data were submitted to three-way ANOVA and Bonferroni post hoc tests (α < 0.05). Three additional teeth were prepared for each group for evaluation of adhesive diffusion into dentin by dyeing the adhesives with a fluorochrome (Rhodamine B). After longitudinal sectioning, the generated interfaces were stored for 24 hours and one year, immersed in fluorescein dye and examined under confocal laser scanning microscopy (CLSM) and SEM (n = 3).

Results: CAD showed μTBS mean values significantly lower (p < 0.0001) than those of sound dentin for all groups at 24 hours. The SE mode on sound dentin showed no signs of degradation or fluorescein infiltration. SBU in the ER mode (CAD) showed the lowest mean μTBS in both storage periods. The ER mode for both adhesives showed exposed collagen fibrils and fluorescein infiltration underneath the hybrid layer of the sound and CAD over time. Although SBUP showed deeper adhesive diffusion into the CAD, no significant difference in μTBS was found between SBUP (ER and SE) and SBUSE after a year of water storage.

Conclusion: Both the BPA-free and BPA-containing adhesives produced similar short- and long-term μTBS to sound dentin. Bond strengths to CAD varied by material and conditioning mode. Qualitative appearance of SEM images suggests that interfacial diffusion in CAD at 24 hours may be enhanced for the BPA-free adhesive. However, both adhesives exhibited degradation after one year of water storage.

一种不含双酚a的万能胶粘剂对健康及龋病牙本质的粘接性能。
目的:目前的通用胶粘剂对龋病牙本质的粘接不可靠,并释放双酚A (BPA)。本研究比较了一种不含双酚a的通用胶粘剂和它的前辈(双酚基),以评估在声音和龋齿影响的牙本质上的粘合性能和界面特性。方法与材料:采用240颗人磨牙进行研究,其中牙本质健全者120颗,龋病牙本质者120颗。采用蚀刻-冲洗(ER)或自蚀刻(SE)方式制备牙本质表面并与Scotchbond Universal Plus (SBU/ BPA-free)或Scotchbond Universal (SBU/BPA-containing)结合。树脂-牙本质黏合试样(1 mm2)在水中保存24小时和1年,测试微拉伸黏合强度(μTBS)。通过扫描电子显微镜(SEM)对失效图像进行分析。数据采用三因素方差分析和Bonferroni事后检验(α < 0.05)。每组再准备3颗牙齿,用荧光染料(罗丹明B)染色,评估粘接剂向牙本质扩散的情况。纵向切片后,将生成的界面保存24小时和1年,浸泡在荧光素染料中,在共聚焦激光扫描显微镜(CLSM)和扫描电镜(SEM)下检查(n = 3)。结果:CAD显示各组牙本质24小时的μTBS平均值均显著低于正常牙本质(p < 0.0001)。正常牙本质的SE模式未见降解或荧光素浸润的迹象。在ER模式(CAD)下SBU的平均μTBS在两个贮存期均最低。两种胶粘剂的ER模式显示,随着时间的推移,胶原原纤维和荧光素浸润在声音和CAD混合层下面。虽然SBUP在CAD中的粘附扩散更深,但SBUP (ER和SE)与sbuuse在1年后的μTBS无显著差异。结论:无双酚a和含双酚a胶粘剂对牙本质的短期和长期μTBS相似。与CAD的结合强度因材料和调节模式而异。定性的SEM图像显示,不含bpa的胶粘剂可以增强24小时CAD中的界面扩散。然而,两种胶粘剂在水储存一年后都表现出降解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书