Effects of Light Curing on the Mechanical Properties and Shade Stability of a Dual-Cure Bulk-Fill Resin Composite.

IF 2.3 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
H Alzraikat, G A Maghaireh, A Alomari, R B Price
{"title":"Effects of Light Curing on the Mechanical Properties and Shade Stability of a Dual-Cure Bulk-Fill Resin Composite.","authors":"H Alzraikat, G A Maghaireh, A Alomari, R B Price","doi":"10.2341/25-131-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Rationale: </strong>Despite the growing use of dual-cure bulk-fill resin composites (RCs), the influence of light-curing protocols on their polymerization and material behavior remains unclear. Understanding these effects is critical for optimizing clinical outcomes.</p><p><strong>Objective: </strong>This study investigated degree of conversion, flexural strength, flexural modulus, water sorption and solubility, and shade stability of a dual-cure bulk-fill RC, Bulk-EZ Plus (BZ), compared to a light-cured bulk-fill RC, Filtek-One Bulk-Fill (FB).</p><p><strong>Methods: </strong>Specimens were randomized into five groups: BZ self-cured (BZ-SC), BZ light-cured for 10-seconds (BZ-10), BZ light-cured for 20-seconds (BZ-20), FB light-cured for 20-seconds (FB-20), and FB light-cured for 40 seconds (FB-40). Degree of conversion was evaluated using FTIR spectroscopy, flexural strength and modulus, and water sorption and solubility were determined following ISO 4049:2019. Shade stability in coffee and distilled water was measured using a spectrophotometer after 24 hours, seven days, and 21 days. Two-way ANOVA assessed the effects of RC type and curing protocol. Shade stability was analyzed using repeated measures and three-way ANOVA (α = 0.05).</p><p><strong>Results: </strong>Light activation increased the flexural modulus of BZ (p = 0.012 and p = 0.001 for BZ-SC vs. BZ-10 and BZ-20, respectively) and flexural strength (p = 0.018 for BZ-SC vs BZ-20), and reduced water sorption (both p < 0.001) and solubility (p = 0.028 for BZ-SC vs. BZ-10 and p = 0.001 for BZ-SC vs BZ-20). Extending light exposure from 20 seconds to 40 seconds did not change the flexural strength and modulus, or water sorption and solubility of FB (all p > 0.05).</p><p><strong>Conclusion: </strong>Light activation improved the physical and mechanical properties of the dual-cure bulk-fill resin composite (Bulk-EZ Plus), but increasing the light exposure time did not improve the properties of the light-cured bulk-fill material (Filtek-One Bulk-Fill).</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"51 2","pages":"167-179"},"PeriodicalIF":2.3000,"publicationDate":"2026-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/25-131-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Rationale: Despite the growing use of dual-cure bulk-fill resin composites (RCs), the influence of light-curing protocols on their polymerization and material behavior remains unclear. Understanding these effects is critical for optimizing clinical outcomes.

Objective: This study investigated degree of conversion, flexural strength, flexural modulus, water sorption and solubility, and shade stability of a dual-cure bulk-fill RC, Bulk-EZ Plus (BZ), compared to a light-cured bulk-fill RC, Filtek-One Bulk-Fill (FB).

Methods: Specimens were randomized into five groups: BZ self-cured (BZ-SC), BZ light-cured for 10-seconds (BZ-10), BZ light-cured for 20-seconds (BZ-20), FB light-cured for 20-seconds (FB-20), and FB light-cured for 40 seconds (FB-40). Degree of conversion was evaluated using FTIR spectroscopy, flexural strength and modulus, and water sorption and solubility were determined following ISO 4049:2019. Shade stability in coffee and distilled water was measured using a spectrophotometer after 24 hours, seven days, and 21 days. Two-way ANOVA assessed the effects of RC type and curing protocol. Shade stability was analyzed using repeated measures and three-way ANOVA (α = 0.05).

Results: Light activation increased the flexural modulus of BZ (p = 0.012 and p = 0.001 for BZ-SC vs. BZ-10 and BZ-20, respectively) and flexural strength (p = 0.018 for BZ-SC vs BZ-20), and reduced water sorption (both p < 0.001) and solubility (p = 0.028 for BZ-SC vs. BZ-10 and p = 0.001 for BZ-SC vs BZ-20). Extending light exposure from 20 seconds to 40 seconds did not change the flexural strength and modulus, or water sorption and solubility of FB (all p > 0.05).

Conclusion: Light activation improved the physical and mechanical properties of the dual-cure bulk-fill resin composite (Bulk-EZ Plus), but increasing the light exposure time did not improve the properties of the light-cured bulk-fill material (Filtek-One Bulk-Fill).

光固化对双固化大块填充树脂复合材料力学性能和遮光稳定性的影响。
原理:尽管双固化体填充树脂复合材料(rc)的使用越来越多,但光固化方案对其聚合和材料行为的影响尚不清楚。了解这些影响对于优化临床结果至关重要。目的:本研究考察了双固化填充型RC (Bulk-EZ Plus, BZ)与光固化填充型RC (Filtek-One bulk-fill, FB)的转化率、抗弯强度、抗弯模量、吸水率和溶解度以及阴影稳定性。方法:将标本随机分为五组:BZ自固化(BZ- sc)、BZ光固化10秒(BZ-10)、BZ光固化20秒(BZ-20)、FB光固化20秒(FB-20)、FB光固化40秒(FB-40)。使用FTIR光谱评估转化程度,弯曲强度和模量,并根据ISO 4049:2019确定吸水性和溶解度。在24小时、7天和21天后,用分光光度计测量咖啡和蒸馏水的遮光稳定性。双向方差分析评估RC类型和治疗方案的影响。采用重复测量和三因素方差分析(α = 0.05)分析遮荫稳定性。结果:光活化提高了BZ的抗弯模量(BZ- sc与BZ-10和BZ-20分别为p = 0.012和p = 0.001)和抗弯强度(BZ- sc与BZ-20分别为p = 0.018),降低了吸水率(p = 0.028)和溶解度(BZ- sc与BZ-10和BZ-20分别为p = 0.001)。将光照时间从20秒延长至40秒,对FB的抗弯强度和模量、吸水率和溶解度均无影响(p < 0.05)。结论:光活化改善了双固化填充树脂复合材料(Bulk-EZ Plus)的物理力学性能,但增加光固化填充材料(Filtek-One bulk-fill)的光固化性能并没有改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书