{"title":"Quantitative Guanidinium CEST-Based pH Mapping at 3 T in Healthy and Pathological Muscle.","authors":"Valentin Henriet, Pierre-Yves Baudin, Benjamin Marty, Marc Lapert, Harmen Reyngoudt","doi":"10.1002/nbm.70352","DOIUrl":null,"url":null,"abstract":"<p><p>Intramuscular pH has been shown to be a valuable biomarker in muscle diseases. Both <sup>1</sup>H and <sup>31</sup>P MRS approaches are commonly used to determine pH in vivo. MRS-based pH measurements are highly sensitive and reproducible but come with limitations: single-voxel approaches and MRS imaging applications suffer from long acquisition times. High spatial resolution pH mapping can be achieved using chemical exchange saturation transfer (CEST), which is intrinsically sensitive to pH. The chemical exchange phenomenon allows for the indirect, noninvasive detection of metabolites by measuring the water signal after a saturation at a given frequency offset. Several metabolites, such as creatine (Cr) and phosphocreatine (PCr), which are abundant in skeletal muscle, were reported to be detectable using CEST in vivo. Moreover, pH changes alter the exchange rate (k<sub>ex,guan2.0</sub>) between guanidinium protons (of Cr and PCr) and bulk water, thereby modifying the CEST effect. In this study at 3 T, we estimate k<sub>ex,guan2.0</sub> based on a three-pool model, verifying the Bloch-McConnell (BM) analytical solution. The method's sensitivity was assessed in a phantom within the physiological pH range. CEST-based pH correlated strongly with the true pH measured with an analytical pH meter (R<sup>2</sup> = 0.97, p < 0.001). The method demonstrated sensitivity to subtle in vivo pH changes on the order of 0.02 pH units in leg muscles of healthy controls at rest and postexercise and in subjects with a neuromuscular disease. The CEST-based pH was significantly decreased in exercised muscle (p < 0.001) and significantly increased in pathological muscles (p < 0.05). This work demonstrates sensitive, high-resolution pH mapping of skeletal leg muscle with an ability to separate healthy from pathological tissue, highlighting its potential as a biomarker for muscle diseases.</p>","PeriodicalId":19309,"journal":{"name":"NMR in Biomedicine","volume":"39 8","pages":"e70352"},"PeriodicalIF":2.8000,"publicationDate":"2026-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13333537/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"NMR in Biomedicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/nbm.70352","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Intramuscular pH has been shown to be a valuable biomarker in muscle diseases. Both 1H and 31P MRS approaches are commonly used to determine pH in vivo. MRS-based pH measurements are highly sensitive and reproducible but come with limitations: single-voxel approaches and MRS imaging applications suffer from long acquisition times. High spatial resolution pH mapping can be achieved using chemical exchange saturation transfer (CEST), which is intrinsically sensitive to pH. The chemical exchange phenomenon allows for the indirect, noninvasive detection of metabolites by measuring the water signal after a saturation at a given frequency offset. Several metabolites, such as creatine (Cr) and phosphocreatine (PCr), which are abundant in skeletal muscle, were reported to be detectable using CEST in vivo. Moreover, pH changes alter the exchange rate (kex,guan2.0) between guanidinium protons (of Cr and PCr) and bulk water, thereby modifying the CEST effect. In this study at 3 T, we estimate kex,guan2.0 based on a three-pool model, verifying the Bloch-McConnell (BM) analytical solution. The method's sensitivity was assessed in a phantom within the physiological pH range. CEST-based pH correlated strongly with the true pH measured with an analytical pH meter (R2 = 0.97, p < 0.001). The method demonstrated sensitivity to subtle in vivo pH changes on the order of 0.02 pH units in leg muscles of healthy controls at rest and postexercise and in subjects with a neuromuscular disease. The CEST-based pH was significantly decreased in exercised muscle (p < 0.001) and significantly increased in pathological muscles (p < 0.05). This work demonstrates sensitive, high-resolution pH mapping of skeletal leg muscle with an ability to separate healthy from pathological tissue, highlighting its potential as a biomarker for muscle diseases.

基于定量胍cest的健康和病理肌肉3t pH定位。
肌内pH值已被证明是肌肉疾病的一个有价值的生物标志物。1H和31P MRS方法通常用于测定体内pH。基于MRS的pH值测量具有高灵敏度和可重复性,但存在局限性:单体素方法和MRS成像应用的采集时间长。使用化学交换饱和转移(CEST)可以实现高空间分辨率的pH映射,CEST本质上对pH敏感。化学交换现象允许通过测量给定频率偏移饱和后的水信号来间接,无侵入性地检测代谢物。一些代谢产物,如肌酸(Cr)和磷酸肌酸(PCr),在骨骼肌中是丰富的,据报道,在体内使用CEST检测。此外,pH的变化改变了(Cr和PCr的)胍质子与散装水之间的交换速率(kex,guan2.0),从而改变了CEST的效果。在本研究中,我们基于三池模型估计了kex,guan2.0,验证了Bloch-McConnell (BM)分析解。该方法的灵敏度在生理pH范围内的幻影中进行了评估。cest测得的pH值与分析pH计测得的真实pH值具有很强的相关性(R2 = 0.97, p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
NMR in Biomedicine
NMR in Biomedicine 医学-光谱学
CiteScore
6.00
自引率
10.30%
发文量
209
审稿时长
3-8 weeks
期刊介绍: NMR in Biomedicine is a journal devoted to the publication of original full-length papers, rapid communications and review articles describing the development of magnetic resonance spectroscopy or imaging methods or their use to investigate physiological, biochemical, biophysical or medical problems. Topics for submitted papers should be in one of the following general categories: (a) development of methods and instrumentation for MR of biological systems; (b) studies of normal or diseased organs, tissues or cells; (c) diagnosis or treatment of disease. Reports may cover work on patients or healthy human subjects, in vivo animal experiments, studies of isolated organs or cultured cells, analysis of tissue extracts, NMR theory, experimental techniques, or instrumentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书